Page 13 of 54
the excess brickwork to the required height, the base of the fire opening (which
the Fire burner and enclosure will sit upon) has to be built.
To create a seal around the appliance and allow correct operation of the flue,
the original fire opening must be closed using bricks or blocks, infill the void
around the enclosure using block work or rubble. (It is advisable to install a
solid base inside the fire opening to sit the steel framework supporting the
burner unit on to.)
Preparing the Fireplace Opening
Above shows the minimum fireplace opening width and height.
The image shows the fireplace opening required to install the fireplace unit. The
gather can be installed by first inserting this into the fireplace opening. The fire
body is then inserted into the opening and the gather lowered down onto the
enclosure. The gather is then fixed from the inside to the enclosure using the
screws provided.
Содержание FR850-NV
Страница 7: ...Page 7 of 54 Construction Dimensions FR 850 V FR 850 NV...
Страница 23: ...Page 23 of 54 Add logs numbered 14 17 Add logs numbered 5 8 Add logs numbered 15 11...
Страница 24: ...Page 24 of 54 Add logs numbered 16 6 Add logs numbered 10 12 Final layout...
Страница 36: ...Page 36 of 54...