background image

Spirent B2-800-QD-4-T1S Installation Instructions

4

|

Spirent B2-800-QD-4-T1S Installation Instructions

PN 71-009377  Rev A May 2022

Attention:  

Avant d'accéder à cet équipement connecté aux lignes électriques, ôter tout 

bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés à l'alimentation et 
reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures 
graves ou souder l'objet métallique aux bornes.

Calibration

At the time of manufacture, all components manufactured by Spirent Communications are 
calibrated in accordance with applicable procedures. Spirent Communications equipment 
is calibrated using national standards, consensus standards, and ratio-type measurements 
based on self-calibration techniques. By design, the equipment has no user adjustments 
and does not require further calibration. Products are calibrated within the published 
environmental specifications for the products. At the time of shipment, this Spirent 
Communications product met its published operating specifications.

Unpacking

Before opening the product carton, examine it for damage. If damage is not visible, 
unpack the carton and check contents for damage. Save all packing materials. If damage is 
noted, forward an immediate request to the delivering carrier to perform an inspection and 
prepare a damage report. Save the container and packing material until contents are 
verified.

Concurrently, report the nature and extent of damage to Spirent Communications 
Customer Support so that action can be initiated to repair or replace damaged items, or 
instructions issued for returning items.

The responsibility of the manufacturer ends with delivery to the first carrier. All claims for 
loss, damage, or nondelivery must be made against the delivering carrier within 
10 calendar days of receipt of shipment.

Damaged or Missing Equipment

If any equipment is damaged or missing, call (800) 774-7368 or (818) 676-2616 
(international) for technical support. Registered users may also access the Spirent 
Communications support website at 

https://support.spirent.com

. You may also email 

questions to

[email protected]

.

Getting Started

B2-800-QD-4-T1S is operated with specialized software designed to help you create and 
analyze realistic traffic for determining the operating characteristics of a device, system, 
or network under test. Due to the powerful traffic generating capabilities of B2-800-QD-4-
T1S, precautions should be taken when connecting the test ports to an operational 
network. On an operational network, such large amounts of traffic can cause network 
congestion leading to unexpected results; for example, packet retransmits or drops.

Содержание B2-800-QD-4-T1S

Страница 1: ...elease Notes for information on supported software applications and versions Getting Started 4 Certifications and Standards 5 Technical Specifications 7 Site Selection 8 Rack Mounting Considerations 8...

Страница 2: ...e Spirent also warrants that if properly used by Customer in accordance with the Software License Agreement the Software which it supplies will operate in material conformity with the specifications s...

Страница 3: ...ts conditions that could cause product damage or data loss Note Describes limitations on the use of the equipment or procedure Children Warning Warning This equipment is not suitable for use in locati...

Страница 4: ...an immediate request to the delivering carrier to perform an inspection and prepare a damage report Save the container and packing material until contents are verified Concurrently report the nature...

Страница 5: ...stalled at the factory prior to shipment If you purchased additional speeds or ports for your appliance the license file will be emailed to you Please contact Customer Support to obtain the license ke...

Страница 6: ...ply systems EN 55035 2017 A11 2020 Electromagnetic compatibility of multimedia equipment Immunity requirements CONFORMS TO UL STD 62368 1 CERTIFIED TO CSA STD C22 2 NO 62368 1 ETL marking This product...

Страница 7: ...ive humidity non condensing The minimum operating temperature is 41 F 5 C Warning Use appropriate ear protection when working in proximity to an operating chassis Chassis Design and Form Factor EIA 19...

Страница 8: ...liance may require safety agency evaluation certification and licensing Check with your building inspector for requirements applicable to your location Notes on Rack Mounting Elevated operating ambien...

Страница 9: ...necting the appliance to your management network and for connecting the NIC test ports to your system under test For cabling information refer to Table 1 on page 10 PC Requirements Refer to the Releas...

Страница 10: ...re 2 shows the connector panels and Table 1 on page 10 describes the connectors on the appliance Figure 2 B2 800 QD 4 T1S Front and Back Panel Connectors 1 3 5 2 6 4 7 8 Table 1 B2 800 QD 4 T1S Connec...

Страница 11: ...Video VGA connector 5 External Time Reference connectors from left to right 10 MHz SMA 1 PPS SMA Serial DCE RJ45 6 Ethernet administration port attach a RJ 45 terminated Cat 5 cable directly to your...

Страница 12: ...ror has occurred Note During initialization the LED state transitions will be Solid Red to Solid Amber to Solid Green The LED will remain red if an error occurs during the initialization sequence Link...

Страница 13: ...Table 3 describes the speed LEDs Table 4 describes the link state LEDs Each test port has eight 8 multi color LEDs to indicate the link state for each possible 400G or sub rate port The LINK LEDs are...

Страница 14: ...numbers above by 8 Then each subsequent cage increments again by 8 in a similar manner For example if the first port groups or QSFP DD800 ports were set to 2x400G PAM4 the ports would be numbered P1...

Страница 15: ...this section Note On B2 800 QD 4 T1S appliances downgrading below 5 33 is not allowed from the GUI To see the available Spirent TestCenter versions using the command line interface 1 SSH to the device...

Страница 16: ...ask and Gateway If you are connecting the appliance to a LAN you will probably need to change the IP address information Obtain an unused IP address netmask and gateway IP address from your IT departm...

Страница 17: ...sets the IP address admin hypervisor netmask shows the current netmask admin hypervisor netmask 255 255 255 0 sets the netmask admin hypervisor gwaddress shows the current gateway address admin hyperv...

Страница 18: ...address2 delete Set the static DNS servers exit Exit gwaddress address Change the gateway address for the device help List all commands hostname Display or change the system hostname ipaddress address...

Страница 19: ...est Module Recovery is not supported on all test modules resetnetwork Reset all network settings to the factory defaults restartsysmgr Restart system manager securemode on off Enable or disable secure...

Страница 20: ...ed to enter the generated password when they attempt to connect to the chassis or appliance These instructions explain how to use Authenticate mode on your chassis Note The Black bold text is user inp...

Страница 21: ...you review all release notes before you install or use the appliance The release notes are available as a Related Resource on the CSC Downloads page https support spirent com If you are using the new...

Страница 22: ...3 1 6137 2270 France Phone 44 1803 546333 UK Hours Monday through Thursday 09 00 to 18 00 Friday 09 00 to 17 00 Paris Time Asia Pacific E mail support spirent com Web https support spirent com Phone 8...

Отзывы: