background image

Spirent B2-800-QD-4-T1S Installation Instructions

Spirent B2-800-QD-4-T1S Installation Instructions

|

3

PN 71-009377  Rev A May 2022

right to change the warranty and service policy set forth above at any time, after 
reasonable notice and without liability to Customer.

TO THE EXTENT PERMITTED BY APPLICABLE LAW, ALL IMPLIED 
WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF 
MERCHANTABILITY, NONINFRINGEMENT AND FITNESS FOR A PARTICULAR 
PURPOSE, ARE HEREBY EXCLUDED, AND THE LIABILITY OF SPIRENT, IF 
ANY, FOR DAMAGE RELATING TO ANY ALLEGEDLY DEFECTIVE PRODUCT 
SHALL BE LIMITED TO THE ACTUAL PRICE PAID BY THE CUSTOMER FOR 
SUCH PRODUCT. THE PROVISIONS SET FORTH ABOVE STATE SPIRENT'S 
ENTIRE RESPONSIBILITY AND CUSTOMER'S SOLE AND EXCLUSIVE REMEDY 
WITH RESPECT TO ANY BREACH OF ANY WARRANTY.

Safety Precautions

Warning

:

 Calls attention to operating procedures or practices that should be followed to 

avoid bodily injury or damage to equipment.

Caution

Reflects conditions that could cause product damage or data loss.

Note

Describes limitations on the use of the equipment or procedure.

Children Warning

Warning:  

This equipment is not suitable for use in locations where children are likely to 

be present.

Waarschuwing

: Deze apparatuur is niet geschikt voor gebruik op locaties waar kinderen 

waarschijnlijk aanwezig zijn.

Attention

: Cet équipement n'est pas adapté à une utilisation dans des endroits où des 

enfants sont susceptibles d'être présents.

No User-Serviceable Parts

Warning:  

No user-serviceable parts inside. Do not open.

Waarschuwing:  

Er zijn geen door de gebruiker te vervangen onderdelen. Niet openen.

Attention:  

Aucune pièce se trouvant à l'intérieur ne peut être réparée ou remplacée par 

l'utilisateur. Ne pas ouvrir.

Lasers Warning

Warning:  

Because invisible radiation may be emitted from the aperture of the port when 

no fiber cable is connected, avoid exposure to radiation and do not stare into 
open apertures.

Waarschuwing:  

Aangezien onzichtbare straling vanuit de opening van de poort kan 

komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken 
in open openingen vermeden te worden.

Содержание B2-800-QD-4-T1S

Страница 1: ...elease Notes for information on supported software applications and versions Getting Started 4 Certifications and Standards 5 Technical Specifications 7 Site Selection 8 Rack Mounting Considerations 8...

Страница 2: ...e Spirent also warrants that if properly used by Customer in accordance with the Software License Agreement the Software which it supplies will operate in material conformity with the specifications s...

Страница 3: ...ts conditions that could cause product damage or data loss Note Describes limitations on the use of the equipment or procedure Children Warning Warning This equipment is not suitable for use in locati...

Страница 4: ...an immediate request to the delivering carrier to perform an inspection and prepare a damage report Save the container and packing material until contents are verified Concurrently report the nature...

Страница 5: ...stalled at the factory prior to shipment If you purchased additional speeds or ports for your appliance the license file will be emailed to you Please contact Customer Support to obtain the license ke...

Страница 6: ...ply systems EN 55035 2017 A11 2020 Electromagnetic compatibility of multimedia equipment Immunity requirements CONFORMS TO UL STD 62368 1 CERTIFIED TO CSA STD C22 2 NO 62368 1 ETL marking This product...

Страница 7: ...ive humidity non condensing The minimum operating temperature is 41 F 5 C Warning Use appropriate ear protection when working in proximity to an operating chassis Chassis Design and Form Factor EIA 19...

Страница 8: ...liance may require safety agency evaluation certification and licensing Check with your building inspector for requirements applicable to your location Notes on Rack Mounting Elevated operating ambien...

Страница 9: ...necting the appliance to your management network and for connecting the NIC test ports to your system under test For cabling information refer to Table 1 on page 10 PC Requirements Refer to the Releas...

Страница 10: ...re 2 shows the connector panels and Table 1 on page 10 describes the connectors on the appliance Figure 2 B2 800 QD 4 T1S Front and Back Panel Connectors 1 3 5 2 6 4 7 8 Table 1 B2 800 QD 4 T1S Connec...

Страница 11: ...Video VGA connector 5 External Time Reference connectors from left to right 10 MHz SMA 1 PPS SMA Serial DCE RJ45 6 Ethernet administration port attach a RJ 45 terminated Cat 5 cable directly to your...

Страница 12: ...ror has occurred Note During initialization the LED state transitions will be Solid Red to Solid Amber to Solid Green The LED will remain red if an error occurs during the initialization sequence Link...

Страница 13: ...Table 3 describes the speed LEDs Table 4 describes the link state LEDs Each test port has eight 8 multi color LEDs to indicate the link state for each possible 400G or sub rate port The LINK LEDs are...

Страница 14: ...numbers above by 8 Then each subsequent cage increments again by 8 in a similar manner For example if the first port groups or QSFP DD800 ports were set to 2x400G PAM4 the ports would be numbered P1...

Страница 15: ...this section Note On B2 800 QD 4 T1S appliances downgrading below 5 33 is not allowed from the GUI To see the available Spirent TestCenter versions using the command line interface 1 SSH to the device...

Страница 16: ...ask and Gateway If you are connecting the appliance to a LAN you will probably need to change the IP address information Obtain an unused IP address netmask and gateway IP address from your IT departm...

Страница 17: ...sets the IP address admin hypervisor netmask shows the current netmask admin hypervisor netmask 255 255 255 0 sets the netmask admin hypervisor gwaddress shows the current gateway address admin hyperv...

Страница 18: ...address2 delete Set the static DNS servers exit Exit gwaddress address Change the gateway address for the device help List all commands hostname Display or change the system hostname ipaddress address...

Страница 19: ...est Module Recovery is not supported on all test modules resetnetwork Reset all network settings to the factory defaults restartsysmgr Restart system manager securemode on off Enable or disable secure...

Страница 20: ...ed to enter the generated password when they attempt to connect to the chassis or appliance These instructions explain how to use Authenticate mode on your chassis Note The Black bold text is user inp...

Страница 21: ...you review all release notes before you install or use the appliance The release notes are available as a Related Resource on the CSC Downloads page https support spirent com If you are using the new...

Страница 22: ...3 1 6137 2270 France Phone 44 1803 546333 UK Hours Monday through Thursday 09 00 to 18 00 Friday 09 00 to 17 00 Paris Time Asia Pacific E mail support spirent com Web https support spirent com Phone 8...

Отзывы: