1.7 Pressure systems

Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider

double isolation (double block and bleed) and the locking or labelling of closed valves. Do not

assume that the system has depressurised even when the pressure gauge indicates zero.

1.8 Temperature

Allow time for temperature to normalise after isolation to avoid danger of burns.

1.9 Tools and consumables

Before starting work ensure that you have suitable tools and/or consumables available. Use

only genuine Spirax Sarco replacement parts.

1.10 Protective clothing

Consider whether you and/or others in the vicinity require any protective clothing to protect

against the hazards of, for example, chemicals, high /low temperature, radiation, noise, falling

objects, and dangers to eyes and face.

1.11 Permits to work

All work must be carried out or be supervised by a suitably competent person. Installation and

operating personnel should be trained in the correct use of the product according to the Installation

and Maintenance Instructions. Where a formal ‘permit to work’ system is in force it must be

complied with. Where there is no such system, it is recommended that a responsible person

should know what work is going on and, where necessary, arrange to have an assistant whose

primary responsibility is safety. Post ‘warning notices’ if necessary.

1.12 Handling

Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing,

pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You

are advised to assess the risks taking into account the task, the individual, the load and the

working environment and use the appropriate handling method depending on the circumstances

of the work being done.

1.13 Residual hazards

In normal use the external surface of the product may be very hot. If used at the maximum

permitted operating conditions the surface temperature of some products may reach temperatures

over 500°C. Many products are not self-draining. Take due care when dismantling or removing

the product from an installation (refer to ‘Maintenance instructions’).

1.14 Freezing

Provision must be made to protect products which are not self-draining against frost damage in

environments where they may be exposed to temperatures below freezing point.

1.15 Safety information - Product specific

See the specific details relating to product in the following ‘Maintenance’ section.

1.16 Disposal

Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable

and no ecological hazard is anticipated with its disposal providing due care is taken.

1.17 Returning products

Customers and stockists are reminded that under EC Health, Safety and Environment Law,

when returning products to Spirax Sarco they must provide information on any hazards and the

precautions to be taken due to contamination residues or mechanical damage which may

present a health, safety or environmental risk. This information must be provided in writing

including Health and Safety data sheets relating to any substances identified as hazardous or

potentially hazardous.

Содержание DT300F

Страница 1: ...Thermodynamic Steam Traps Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation 6 Maintenance 7 Spare parts Th...

Страница 2: ...3 333 5275 247 2...

Страница 3: ...urezza La ghisa un materiale fragile in caso di caduta accidentale il prodotto in ghisa non pi utilizzabile Per informazioni pi dettagliate consultare il manuale d istruzioni del prodotto Rimuovere la...

Страница 4: ...d ariete Prevention of water hammer Scarico condensa nelle linee vapore Steam trapping on steam mains Intervalli di 30 50 m intervals Pendenza Gradient 1 100 Vapore Steam Gruppo di scarico Trap set Co...

Страница 5: ...ducts or re assembling after maintenance Evitare l eccessivo serraggio Utilizzare le coppie di serraggio raccomandate Do not over tighten Use correct torque figures Per garantire l uniformit del caric...

Страница 6: ...rom the bellows manufacturer Guide Guides Distanza breve Short distance Punto di fissaggio Fixing point Movimento assiale Axial movement Distanza media Medium distance Tiranti limitatori Limit rods Pi...

Страница 7: ...Consider flammable materials substances hazardous to health extremes of temperature 1 5 Hazardous environment around the product Consider explosion risk areas lack of oxygen e g tanks pits dangerous g...

Страница 8: ...ing carrying or supporting a load by bodily force can cause injury particularly to the back You are advised to assess the risks taking into account the task the individual the load and the working env...

Страница 9: ...fied at the time of order Available types Four different executions with differentiated internal mechanism type A B C D and sized in accordance to the discharge capacity requirements 2 2 Pipe connecti...

Страница 10: ...imum allowable pressure DT300F A B C 20 C 430 bar g DT300F D 20 C 365 bar g TMA Maximum allowable temperature DT300F A B C 113 bar 560 C DT300F D 100 bar 560 C Minimum allowable temperature 10 C PMO M...

Страница 11: ...3 333 5275 247 7 2 5 Capacities The condensate discharge capacities can be deduced by the diagram below shown Condensate kg h Differential pressure bar g Hot water capacity Cold water capacity...

Страница 12: ...hing that is caused with a very high differential pressure 3 4 With a piped discharge to recovery system the pipe should be sized with a maximum flash steam speed of 20 25 m s 3 5 Do not install the s...

Страница 13: ...trim set using the following spanners Trim set A 32 mm spanner Trim set B 36 mm spanner Trim set C 41 mm spanner Trim set D 50 mm spanner 3 After cleaning all joint faces fit the new unit and tighten...

Страница 14: ...spares Always order spare parts by using the description given in the table and state the type of trap the internal trim set type and size of the connections Example 1 Internal trim set for a DT300F...

Страница 15: ...3 333 5275 247 11...

Страница 16: ...9 17 1 Fax 0362 49 17 307 REPAIRS Please contact our nearest Branch Office or Agent or directrly Spirax Sarco S r l Via per Cinisello 18 20834 Nova Milanese MB Tel 39 0362 49 17 1 Fax 39 0362 49 17 30...