5 - Maintenance
Page 16
5.4 - Changing the Hydraulic Oil
Insert the included Plastic Funnel into the Oil Tank and, using a new batch of Hydrol HL Oil (HL3HY) or an equivalent
brand, fill the tank with 1-1/2 gallons or until the Oil Tank is approximately 3/4 filled with oil.
Replace the Cap making sure it is sealed securly.
Replace the Back Cover by securing the eight (8) hex screws that hold it in place.
After changing the oil it will be necessary to work the air out of the system. This is done by turning the power to the
Hydraulic Motor on and activating the foot pedal to raise and lower the table. Air in the hydraulic lines may make the
table motion irratic. Continue raising and lowering the table until the machine responds in the usual way indicating
the all the air has been bled out of the hydraulic lines.
5.4.6
5.4.7
5.4.8
5.4.9
Funnel (included)
Oil Tank
Hydrol HL (recommended)
Diagram 5-80
Содержание FMMH 3.1
Страница 4: ...2 Safety 2 2 Warning Labels Page 03 WARNING DO NOT EXPOSE TO RAIN OR USE IN DAMP LOCATIONS...
Страница 20: ...7 Parts Diagrams 7 1 Side View Page 19...
Страница 21: ...7 Parts Diagrams 7 2 Head Assembly Page 20...
Страница 22: ...7 Parts Diagrams 7 3 Spindle and Chuck Assembly Page 21...
Страница 23: ...7 Parts Diagrams 7 4 Rear View Page 22...