Operation manual - Spider ILD01G
24 / 54
rev. 03-01-04-2019
9.2 HYDRAULIC PUMP BY-PASS
The By-pass is used to disable the hydraulic drive and to
engage the oil bypass for manual handling (engine not
running) of the machine on flat surfaces. The by-pass
should only be used when the hydraulic drive is not
functional. For normal hydraulic drive it is necessary to
have the bolt on the pump tightened. For manual
handling loosen this bolt by two revolutions.
Before starting, check the bolt tightness. If
loose, it will disable the hydraulic drive.
Insufficient
tightening
may
result
in
undesirable behaviour of the mower on slopes.
It may uncontrollably drive down a slope.
9.3 CHECKING ENGINE OIL LEVEL
Attention! Before checking or refilling oil stop the
engine and let it cool down.
The oil level of the machine standing on a level surface
must be between the limit marks on the dipstick (see the
engine user’s manual). Check oil according to the engine
user’s manual as follows:
1)
Place the machine on a level surface.
2)
Remove the upper body
3)
Unscrew the dipstick and wipe off oil.
4)
Without screwing inset the dipstick back into the
filler as far as you can.
5)
If the oil level is close or under the lower limit
mark (ADD), fill with recommended oil up to the
upper limit mark (FULL).
6)
Refit the dipstick.
Running the engine with insufficient oil
may cause serious damage to the
engine.
Check the engine oil level on a level surface and
only when the engine is off.
Use only oil recommended by the engine
manufacturer.
min max