Technical data
Thermo E 200/320
62
Heater
Thermo E 200
Thermo E 320
Kind of construction
High pressure atomizer
Rated heating flow
kW
20
32
Fuel
Diesel / Heating oil
Fuel consumption
kg/h
2,0
3,2
Rated voltage
V =
24
Operating voltage range
V =
20.5...30.0
Rated power consumption at 24V
W
55
100
Temperature of sucked com-bustion air
°C
-40...+ 85
Ambient temperature during operation
°C
-40...+ 85
Storage temperature
°C
-40...+ 90
Operating overpressure
bar
max. 2.0
Capacity of the heat exchanger
l
1.8
Minimum water flow
± …l/h
2400 ± 200
2700 ± 200
Minimum capacity of the water system
l
min. 25.0
CO
2
in exhaust gas at rated voltage
Vol %
9.5 ± 0.5
10.0 -0.5 / +0.8
CO
2
in exhaust gas with application at rated
voltage
Vol %
9.5 ± 0.5
9.5 -0.5 / +0.8*
10.0 -0.5 / +0.8
10.0 -0.5 / +2.0**
Heater dimensions
(tolerance
±
3 mm)
mm
Length 593 / Width 247 / Height 224
Weight
kg
16.5
17.3
* If at voltages less the rated voltage the smoke spot number acc. Bacharach keeps
≤
4.
Reference value: Possibly increased soot at CO
≥
60 ppm resp. CO
≥
0,006 Vol %.
** If at voltages less the rated voltage the smoke spot number acc. Bacharach keeps
≤
4.
Reference value: Possibly increased soot at CO
≥
100 ppm resp. CO
≥
0,01 Vol %.
Содержание Thermo E 200
Страница 36: ...Technische Daten Thermo E 200 320 32...
Страница 68: ...Technical data Thermo E 200 320 64...
Страница 100: ...Datos t cnicos Thermo E 200 320 96...