![Spheros CC 305 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/spheros/cc-305/cc-305_owners-manual_1347081025.webp)
24
1.2.11 FAILURES
When any failure occurs in the air conditioning system, the display will show a
message as shown below
Important:
Whenever a failure to the air conditioner system is identified, the
vehicle must be sent to a Spheros authorixed sevice station.
FAILURE
DESCRIPTION
Pressure Switch failure
Temperature sensor open
Temperature sensor in shock
Alternator failure
1 - If any failures occurs to the pressure switch, the display will show the massage
(HA) and de system will shut the compressor off. The controller will wait for 3 minutes
before turning the compressor again, once the failure is corrected.
2 - As the system operates according to the internal temperature, the controller has
two failure codes to monitor the temperature sensor:
a) If the temperature sensor is open, the display will show (OP)
b) If the temperature sensor is in shock, the display will show (SC)
3 - This controller has a paremeter to monitoring the alternator. In case of failure in the
alternator the display will show (AL).
FAILURES
DESCRIPTION
Alternator failure
Air return sensor failure
Duct sensor failure
External sensor failure
Pressure Switch failure
Communication failure
Valve connection failure
1 - This controller has a parameter to monitoring the alternator. In case of failure in the
alternator the display will show (AL), however the controller outlets will continue to be
on
2 - Should there be a failure in the air return sensor, the display will show (FI).
3 - Should there be a failure in the air duct sensor, the display will show (F3).
4 - Should there be a failure in the external sensor, the display will show (F5).
5 - Should a pressure failure occurs, the display will show the massage (FP) and the
system will shut the compressor off. The system will wait for 3 minutes before turning
on the compresor again, once the failure is corrected.
6 - Should there be a communication failure the display will show (FC) and only the
cooling mode will work.
7 - Should the heating system valve connection fail, the display will show (EI).
1.2.11.1 CONTROLLER GL-W163 ALARM FAILURES
1.2.11.2 CONTROLLER GL-210 ALARM FAILURES
Operating the air conditioner