background image

1 - SPHEROS WARRANTY TERMS.

SPHEROS CLIMATIZAÇÃO DO BRASIL S/A guarantees its products for the 

period of one year, counted from the equipment installation date, which is stated 

on the cover of the warranty certificate.

In case a third party installs the equipment, Spheros guarantees only the product 

and not its installation.

No claim will be accepted if the vehicle continues to be used after the evidence 

of defect, even if there is lack of parts, delays in transportation or any other 

incident.

1 – The warranty will be valid for the period above specified, counted from the 

equipment installation date made by the first buyer/consumer, even though the 

property has been transferred.

2 – During the stipulated period, the warranty covers totally the workmanship 

and  spare  parts  when  repairing  defects  duly  identified  as  being:  equipment 

manufacturing; primary failure of material and defects of components used on 

its manufacturing.

3 – Only a technician from the spheros authorized net of services is qualified to 

repair the defects covered by the warranty.

4 – The repair or replacement of defective parts, performed by an authorized service 

station, will not incur in any debit regarding parts and workmanship used.

5  –  The  warranty  approval  is  conditioned  to  the  technical  analysis  of  the  

defect presented on the components and operational conditions to which the  

equipment was submitted.

6  – The  warranty  of  the  components  used  on  the  assembly  of  the  Spheros  

equipment, which have their own net of technical assistance, will be obtained from 

its own net, by presenting the Spheros warranty certificate. Having as example 

the alternator case, it should be forwarded to the Bosch net.

7 – THE WARRANTY LOSES ITS VALIDITY:

a) If the installation or use of the product is not in accordance with the Spheros 

technical recommendations.

THE WARRANTY WILL ONLY BE VALID BY PRESENTING THE 

 

ORIGINAL WARRANTY CERTIFICATE.

Spheros  warranty  terms

b) If  the  product  suffers  any  damage  caused  by  accident,  nature  agents, 

misuse,  or  yet  alterations  and  repairs  performed  by  any  other  than  the  

manufacturer’s authorized technicians.

c) If  the  warranty  certificate  and/or  the  serial  number  of  the  product  is 

 

adulterated, overwritten or damaged.

d) If  defects  or  unsatisfactory  performance  are  caused  by  the  use  of  not 

original  spare  parts and  in  disagree  with  the technical  specifications  from 

SPHEROS.

8 – THE WARRANTY DOES NOT COVER:

a) Transportation expenses to the repair facility. In case the consumer decides 

to be attended in the same place the product operates, the collection or not 

of the visit tax will be the criterion of the Authorized Service.

b) The attendance to the consumer, free or paid, in cities that do not have 

Authorized Services. Being thus the expenses with displacement are of total 

responsibility of the owner.

c) Failure of proper preventative maintenance, according to the described in 

this manual, on the preventative maintenance item.

d) Revisions, external adjustments and cleaning, therefore these information 

are listed on the owner’s guide.

e) Parts that wear out naturally.

Are  considered  components  of  natural  wear  out:  belts,  filters  in  general, 

lubricant oil, relays and fuses.

f)   Losses or losses of profits caused by the stop of the vehicle due to the not 

functioning of the air conditioning equipment.

Содержание CC-160T

Страница 1: ...conditioner Midibus We recommend a careful reading of this manual prior starting the operation of your air conditioner to obtain its best performance Keep it for future references Recomendamos leer a...

Страница 2: ...presentaci n del certificado de garant a Spheros Como ejemplo el caso del alternador que debe ser encaminado para la red Bosch 7 L A GARANT A PERDER SU VALIDAD a Si la instalaci n o utilizaci n del p...

Страница 3: ...by presenting the Spheros warranty certificate Having as example the alternator case it should be forwarded to the Bosch net 7 THE WARRANTY LOSES ITS VALIDITY a If the installation or use of the produ...

Страница 4: ...E EL INVIERNO 4 4 ACEITE Y FILTRO DESHIDRATADOR 5 ESQUEMAS EL TRICOS 5 6 6 6 6 6 6 7 8 8 8 9 9 10 11 11 11 11 12 12 12 12 13 14 14 15 16 17 17 19 19 19 20 1 AIR CONDITIONER IDENTIFICATION 2 OPERATION...

Страница 5: ...ct the technical assistance department INTRODUCCI NES La Spheros desenvuelve sus productos preocupada en ofrecer a los pasajeros un ambiente confortable buscando siempre la mejor condici n de climatiz...

Страница 6: ...o y en la tarjeta de identificaci n ver figura 1 En la tarjeta consta tambi n el tipo de gas refrigerante utilizado y cantidad necesaria para el modelo Informaciones referentes a aplicaciones como N d...

Страница 7: ...igeraci n 2 1 2 ACCIONAMIENTO DEL EVAPORADOR El control de velocidad de los ventiladores del evaporador es hecho autom ticamente de acuerdo con la temperatura programada y la temperatura interna del c...

Страница 8: ...lay mostrar la sigla AL ver iten 2 3 6 7 10 9 8 12 11 2 3 1 5 6 4 1 Display num rico 2 Tecla control de ventilaci n VENT 3 Tecla control de refrigeraci n REFRIG 4 Tecla control de renovaci n del aire...

Страница 9: ...velocidad alta presione nuevamente la tecla VENT Esta funci n ser informada por el indicativo 10 encendido 3 Presionando una vez m s la tecla VENT desactivar el modo ventilaci n Con el modo refrigera...

Страница 10: ...de temperatura estuviera en corto circuito el display mostrar SC 3 Este controlador posee un par metro para monitorear el alternador Caso el alternador no estuviera cargando el display mostrar el c di...

Страница 11: ...xterna ubicado en el exterior del equipo de aire acondicionado c Sensor de temperatura de los conductos ubicado en los conductos del aire 8 11 10 9 14 13 12 2 3 7 1 5 6 4 1 Display num rico 2 Tecla co...

Страница 12: ...i n est en modo autom tico 2 3 4 CALENTAMIENTO CON AIRE ACONDICIONADO DE TECHO CALEFACCI N 1 Despu s de seleccionar el modo Auto conforme iten 2 4 1 si la temperatura interna del veh culo estuviera ab...

Страница 13: ...n caso de que la renovaci n del aire estuviera abierta cuando el modo refrigeraci n entre en operaci n la misma ser autom ticamente cerrada Convectores serpentinas de calentamiento instaladas por la m...

Страница 14: ...el ctrica en la v lvula de calefacci n el display mostrar EI 2 3 9 FALLAS Este controlador posee un sistema de monitoreo de fallas Cuando ocurriera alguna falla en el sistema del aire acondicionado el...

Страница 15: ...e El sistema el ctrico est compuesto por una placa de potencia ubicada en el evapora dor que es comandada por un controlador electr nico ubicado junto al panel del con ductor El controlador recibe inf...

Страница 16: ...ante est sujeta a alteraciones de acuerdo a la aplicaci n e instalaci n AIRE ACONDICIONADO GAS REFRIGERANTE EMBRAGUE COMPRESOR CONDENSADOR EVAPORADOR CC160T 60 000 BTU h R 134a 3 5 kg centr fugo 4 420...

Страница 17: ...061 000 038 00007 001 021 00014 000 021 00020 000 CC160T CC170T CC200T CC160T CC170T CC200T DESCRIPCI N C DIGO ITEM 8 9 10 12 13 11 V lvula de expansi n Serpent n evap dir Serpent n evap esq Placa de...

Страница 18: ...l Instalar los man metros y registrar las presiones temperatura y condiciones de la l nea de succi n Verificar la carga del refrigerante X X Inspeccionar visualmente si hay marcas de desgastes y deter...

Страница 19: ...EL CTRICA Verificar la secuencia del termostato refrigeraci n ventilaci n refrigeraci n calefacci n Verificar el alternador X X Verificar el aprieto del cable de potencia en la placa de relees X Inspe...

Страница 20: ...a o mec nico Todos los componentes que no estuvieran en perfecto estado deber n ser substituidos por motivo de seguridad 4 4 ACEITE Y FILTRO DESHIDRATADOR Para asegurar la operaci n del aire acondicio...

Страница 21: ...OR COM N 1 2 NC 3 EVAPORADOR COM N 2 4 EVAPORADOR BAJA VELOCIDAD 1 5 NC 6 EVAPORADOR BAJA VELOCIDAD 2 7 EVAPORADOR ALTA VELOCIDAD 1 8 NC 9 EVAPORADOR ALTA VELOCIDAD 2 1 2 6 8 3 5 4 7 9 1 2 6 8 3 5 4 7...

Страница 22: ...L R 5 L R 4 L R 6 L R 3 L R 8 L R 9 L R 2 L R 2 1 L R 1 1 L R 0 1 L R 1 L R 9 5 1 4 PRESOSTATOS ALTA BAJA 12 V REL EXTERNO PARA CORTINA DEL AIRE ICE RL9 RL8 RL10 RL11 RL6 RL12 CN1 CN1 CN4 CN5 CN6 CN1...

Страница 23: ...LIMATIZA O do BRASIL e fornecido com objetivo estritamente confidencial n o devendo ser divulgado para terceiros reproduzido ou usado com prop sito de fabrica o sem expressa e escrita permiss o da com...

Страница 24: ...LIMATIZA O do BRASIL e fornecido com objetivo estritamente confidencial n o devendo ser divulgado para terceiros reproduzido ou usado com prop sito de fabrica o sem expressa e escrita permiss o da com...

Страница 25: ...LIMATIZA O do BRASIL e fornecido com objetivo estritamente confidencial n o devendo ser divulgado para terceiros reproduzido ou usado com prop sito de fabrica o sem expressa e escrita permiss o da com...

Страница 26: ...oner s Warranty Certificate and on the identification tag See picture 1 On this tag it is also informed the refrigerant gas to use and necessary quantity for the model Information regarding the applic...

Страница 27: ...1 2 TURNING THE EVAPORATOR ON The velocity control from the evaporator blower is automatically adjusted according to the temperature programmed and the temperature inside the vehicle When the internal...

Страница 28: ...e start the display will show the initials AL see item 2 3 6 1 Numeric Display 2 Ventilation control key VENT 3 Cooling control key REFRIG 4 Refresh control key RENOV 5 Key INCREASE 6 Key DECREASE 7 1...

Страница 29: ...velocity press VENT key again This func tion will be informed by having indicator 10 on 3 pressing the key VENT one more time the ventilation mode will be turned off When the cooling mode on the vent...

Страница 30: ...lay will show OP b If the temperature sensor is in shock the display will show SC 3 This controller possesses a parameter to monitor the alternator In case of failure or in case the alternator is not...

Страница 31: ...ning system see components b External temperature sensor located outside the air conditioning equipment c Duct temperature sensor located in the air ducts 8 11 10 9 14 13 12 2 3 7 1 5 6 4 1 Numeric Di...

Страница 32: ...t the ventilation is on automatic mode 2 3 4 ROOF HEATING CALEFACTION 1 After selecting the Auto mode according to item 2 4 1 and if the internal temperature of the vehicle is below the set point the...

Страница 33: ...cooling mode starts to work it will be automatically shut Conveyors heating coils installed by the body manufacturer They are normally located on the lateral of the passenger s aisle below the seat Th...

Страница 34: ...and only the cooling mode will work 7 In case the heating system valve connection fails the display will show EI 2 3 9 FAILURES This controller is equipped with a failure system monitor When any failu...

Страница 35: ...g to the environmental protection law The electrical system is composed of a power panel located on the evaporator which is controlled by the electronic controller positioned together to the driver s...

Страница 36: ...plication and installation AIR CONDITIONING REFRIGERANT GAS CLUTCH COMPRESSOR CONDENSER EVAPORATOR CC160T 60 000 BTU h R 134a 3 5 kg centrifugal 4 4200 m 3 h 46 A axial 2 1800 m 3 h 36 A UX200 UP200 2...

Страница 37: ...0007 001 021 00014 000 021 00020 000 CC160T CC170T CC200T CC160T CC170T CC200T DESCRIPTION REF nr ITEM 8 9 10 12 13 11 Expansion valve Evaporating coil right Evaporating coil left Relay plate GL W143...

Страница 38: ...Visually inspect the clutch plate X Visually inspect the condition tension and alignment of the compressor s belts X Clean the compressor and the clutch with vapor or hot water X Measure the resistan...

Страница 39: ...r any cost resulting from the bad quality of air offered to their passengers ELECTRICAL Check the thermostat sequence cooling ventilation cooling calefaction Check the alternator X X Check the tightne...

Страница 40: ...attention must be given to corrosion signs or any mechanical damage All components which do not show perfect condition must be replaced for security measures 4 4 CHANGE OF OIL AND DRYER FILTER To ens...

Страница 41: ...6 LOW SPEED BLOWER 2 7 HIGH SPEED BLOWER 1 8 NC 9 HIGH SPEED BLOWER 2 1 2 6 8 3 5 4 7 9 1 2 6 8 3 5 4 7 9 CN1 1 2 6 8 3 5 4 7 9 1 2 6 8 3 5 4 7 9 1 2 6 8 3 5 4 7 9 1 2 6 8 3 5 4 7 9 1 6 8 3 2 5 4 7 9...

Страница 42: ...L R 2 1 L R 1 1 L R 0 1 L R 1 L R 9 5 1 4 PRESOSTATOS HIGH LOW 12 V EXTERNAL RELAY FOR AIR BARRIER ICE RL9 RL8 RL10 RL11 RL6 RL12 CN1 CN1 CN4 CN5 CN6 CN1 CN1 CN2 CN1 CN1 CN5 CN5 1 1 7 4 COMMOM HIGH S...

Страница 43: ...IMATIZA O do BRASIL e fornecido com objetivo estritamente confidencial n o devendo ser divulgado para terceiros reproduzido ou usado com prop sito de fabrica o sem expressa e escrita permiss o da comp...

Страница 44: ...IMATIZA O do BRASIL e fornecido com objetivo estritamente confidencial n o devendo ser divulgado para terceiros reproduzido ou usado com prop sito de fabrica o sem expressa e escrita permiss o da comp...

Страница 45: ...IMATIZA O do BRASIL e fornecido com objetivo estritamente confidencial n o devendo ser divulgado para terceiros reproduzido ou usado com prop sito de fabrica o sem expressa e escrita permiss o da comp...

Страница 46: ...50 Caxias do Sul RS Brasil Tel Phone Fone 55 54 2101 5700 Fax 55 54 2101 5747 Email spheros spheros com br www spheros com br Todas las informaciones contenidas em nuestro manual estan sujetas a alter...

Отзывы: