12
Panther HIP-PAC
VI. MAINTENANCE
WARNING
Specialized processes are required to
disinfect and decontaminate a respira
-
tor. You MUST follow the instructions
of the manufacturer who supplies the
disinfecting or decontamination equip
-
ment or chemicals. Failure to comply
with this Warning may lead to seri-
ous personal injury, serious illness, or
death.
CAUTION
• DO NOT clean the facepiece with the
regulator attached.
• You must ensure that this respirator is
not damaged when using disinfecting or
decontamination equipment or chemi-
cals.
• The facepiece lens can be scratched
through careless or abusive handling.
DO NOT use abrasive cleaners or pads.
DO NOT towel dry.
NOTE
Inspect the Panther HIP-PAC for defects
before and after each use, and at least once
monthly if not used. Repair as necessary,
clean and disinfect after each use, and store
properly to assure that the Panther HIP-
PAC is maintained in satisfactory working
condition. Keep a record of inspection
and repair dates and results. Refer to the
inspection table in the back of this manual.
A. Conventional Facepiece Cleaning
NOTE
Silicone and rubber parts of the facepiece
may be cleaned between washings with
SPERIAN Mask Wipes, P/N 140096.
1. Make a cleaning solution of warm water and a
mild detergent.
2. Fully immerse the facepiece in the solution.
3. Agitate the facepiece and gently clean with a soft
brush.
4. Thoroughly rinse the facepiece in fresh water,
paying particular attention to removal of all soap
residue from the exhalation valve. If possible, direct
running water onto the exhalation valve.
5. Allow the facepiece to drip dry. Warm air may be
used to speed up drying.
H. Use of the 21 Series Drink Tube
Th
e drink tube allows the user to consume fluids
while wearing the 21 Series facepiece and is com-
patible with a MIL-C-51278 water canteen cap.
WARNING
• Using the drink tube in a contaminated
area or after leaving a contaminated
area may expose you to contaminants.
Use the drink tube in accordance with
instructions provided by the IC or ICS.
• Failure to comply with this warning
may lead to personal injury, illness, or
death.
1. While wearing the 21 Series facepiece, remove
the drink tube coupling from the retainer and insert
it into a MIL-C-51278 canteen cap.
2. Use mouth movements to insert the drink tube
mouthpiece inside the nose cup into your mouth.
3. Hold the canteen upside down higher than the
mouthiece and suck the fluid into your mouth as
shown in Figure 11.
4. When through drinking, turn the canteen right
side up and remove the mouthpiece from your
mouth.
5. Remove the coupling from the canteen cap and
return the coupling to the drink tube retainer.
Figure 11. 21 Series Drink Tube