Sperian Panther Hip-Pac 9649 Скачать руководство пользователя страница 10

8

Panther HIP-PAC

Figure 5. Waist Belt D-ring

9. Insert the second stage regulator into the regulator 
receiver on the waist belt.

10. Open the (optional) shoulder strap to its maximum 
position. Place the shoulder strap over the left shoul-
der and position the shoulder pad on the top of the left 
shoulder. Adjust the shoulder strap to raise the cylin-
der,  and  to  raise  the  waist  belt  into  position  around 
the waist.
11. Position the cylinder so that the cylinder is located 

slightly behind the right hip, latch the belt buckle, and 

adjust  both  the  waist  and  shoulder  straps  (if  used) 
for  comfort.  Pull  the  loose  end  of  the  waist  strap  to 
tighten.
12.  Connect  the  air  line  hose  to  the  remote  air 
supply.

NOTE

When using Foster fittings, always ensure that the 

locking sleeves are rotated to the locked position.

13. When donning the respirator without the optional 
shoulder  strap,  follow  the  same  procedures  except 
omit step 10.

14. Tighten the AIR KLIC on the facepiece by turning 

it clockwise.

15.  Verify  that  the AIR  KLIC  is  secured  by  trying  to 

turn it counterclockwise.

WARNING

The  AIR  KLIC  must  be  held  securely 

in  the  nozzle  by  the  ratchet-and-pawl 

mechanism.  If it is necessary to use a 

respirator that has been stored at a tem-

perature  below  freezing  (32°F  or  0°C) 

prior to using, then DO NOT exhale into 

the  facepiece  until  the  facepiece  has 

been  properly  donned  with  the  nose 

cup  situated  properly  on  the  face  and 

the  regulator  installed  and  activated. 

Failure  to  comply  with  this  Warning 
may lead to serious personal injury, se-
rious illness, or death.

16.  There  are  two  methods,  depending  upon  which 
head  harness  is  used,  to  secure  the  Classic

  or 

TwentyTwenty Plus facepiece to the user. Both meth-
ods are described below.

a. Standard silicone headstrap:

i. Fully loosen the headstraps. 

ii. If your SCBA is equipped with a neck strap, 

place the neck strap over your head.

iii.  Grasp  the  lower  headstraps  as  shown  in 
 Figure 6.

iv. Place your chin in the chin cup and pull the 
straps over your head.

v. Center the facepiece and flatten the head

-

strap hub on the back of your head.

vi. Tighten the two lower straps. Do not over-
tighten.
vii. Tighten the temple straps (Figure 7), then 

the top strap, until all the headstraps lie flat on 

your head.

Figure 7. Tighten Upper Straps

viii. Perform a leak check as described below.

NOTE

When  properly  adjusted,  the  headstrap 

hub  should  be  centered  on  the  back  of 

your head, and the lower straps should be 

below your ears. Make sure that your chin 

is properly recessed in the chin cup.

b. Optional Headnet

i. Inspection

• 

Classic  Facepiece

—Ensure  that  the  three 

locking fabric straps located across the forehead 

are positioned so that they do not slip out from 

under the buckles.
• 

TwentyTwenty Plus Facepiece and 21  Series 

Facepiece

—Ensure that the three locking fab

-

ric  straps  located  across  the  forehead  are  fully 
inserted into their slots in the rims and that the 

locking flaps prevent the straps from pulling out 

of the slots.

Figure 6. Grasp Lower 

Headstraps

Содержание Panther Hip-Pac 9649

Страница 1: ...D BREATHING APPARATUS P9684 SERIES 5 and 10 Minute Escape P9685 SERIES 15 Minute Escape P9686 SERIES HP 10 Minute Escape 9649 SERIES HP 10 Minute Escape OPERATION MANUAL WARNING DO NOT USE this respir...

Страница 2: ......

Страница 3: ...valve and pressure gauge assembly first stage regulator second stage regulator facepiece waist belt and regulator hose The cylinder stores 8 cubic feet of air at 2216 psig for the 5 minute apparatus...

Страница 4: ...st cannot be obtained See ANSI Z88 2 latest edition and OSHA 1910 134 Beards and side burns will prevent good facepiece seal Do not use this respirator unless you are clean shaven WARNING Continued Th...

Страница 5: ...ering the face piece and causing a severe reaction Do not use this respirator if you have been sensitized from previous exposure or believe that you may be sensitive or al lergic to any chemical until...

Страница 6: ...tacles Kit all 2020 Series Facepieces Wire Frame 964044 Spectacles Kit all 2020 Series Facepieces NexSpex B140095 Lens Cover Clear Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 L...

Страница 7: ...Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 Lens Cover Clear TwentyTwenty Plus 951015 Anti fog Solution 1 oz 951016 Anti fog Solution 16 oz 981805 Anti fog Wipes Box of 100 B14...

Страница 8: ...rator hose This operation requires a torque wrench WARNING Carefully inspect and clean all threads to remove foreign material Foreign ma terial entering the air line can restrict or block air flow to...

Страница 9: ...turned on while connect ed to the air supply will cause loss of air in the cylinder resulting in reduced es cape time in case of an emergency Always disengage the regulator from the facepiece and ret...

Страница 10: ...operly on the face and the regulator installed and activated Failure to comply with this Warning may lead to serious personal injury se rious illness or death 16 There are two methods depending upon w...

Страница 11: ...ens The Challenge NXT PVC lens neoprene neck seal and adhesive all may react in a different manner when exposed to chemicals or chemical mixtures You must verify that none of the components of the hoo...

Страница 12: ...tons when installing the regulator WARNING Rotate and tug the regulator to ensure that both release buttons are properly engaged in the AIR KLIC Do not push the release buttons while verifying the eng...

Страница 13: ...eathing exhale forcefully The regulator should return to normal flow b If the free flow continues open and close the by pass once or depress the manual override button once c If the problem persists I...

Страница 14: ...water and a mild detergent 2 Fully immerse the facepiece in the solution 3 Agitate the facepiece and gently clean with a soft brush 4 Thoroughly rinse the facepiece in fresh water paying particular a...

Страница 15: ...cleaning may require reapplication of anti fog coating to the facepiece lens Use only SPERIAN Anti Fog Solution P N 951015 1 oz or P N 951016 16 oz 6 After cleaning three drops of anti fog solution m...

Страница 16: ...ly rinse the exterior surfaces and the interior of the outlet tube with fresh water Scrub excess soap away with the brush 5 Dry with a clean cloth or with low pressure 15 psig maximum clean breathing...

Страница 17: ...F Cylinders damaged by fire or exposed to heat of 350 F must be destroyed Repainted or refinished cylinders must be hydrostatically tested before reuse WARNING Continued Do not fill a composite cylind...

Страница 18: ...l be maintained at 65 F 53 9 C or lower or less than 24 0 ppm by volume moisture content UNDER NO CIRCUM STANCES SHALL AN AIR CYLINDER BE FILLED OR PARTIALLY FILLED WITH OXYGEN b Maximum Fill Pressure...

Страница 19: ...cold weather problems however cold weather condi tions may also cause other problems not listed below 1 Air Supply NOTE Cold weather conditions require very dry air Moisture entering the HIP PAC may...

Страница 20: ...e and regulator until the normal function of the AIR KLIC button and or the shutoff button returns j Should ice form on the regulator while the regula tor is in the regulator receiver rotate the regul...

Страница 21: ...tures especially if there is ice d Use HIP PAC accessories with extreme care in cold weather conditions Visually inspect them pe riodically for ice J Storage Inspect clean and repair as required befor...

Страница 22: ...placement or repair of defective parts and such other necessary maintenance and repair as may be required Normal wear and tear and parts damaged by abuse misuse negligence or accidents are specificall...

Страница 23: ...k seal to tear SECOND STAGE REGULATOR AND HOSE 1 Cracks or heat damage to housing or cover 2 Faulty operation of bypass valve First Breath On AIR KLIC or override buttons 3 Dirt and debris in the outl...

Страница 24: ...remove the rim nuts and screws 2 Gently separate the rims from the facepiece 3 Pull the silicone skirt away from the lens 4 Remove the old lens 5 Match one corner of the new lens with a corner of the...

Страница 25: ...disconnect nipple 4 Listen to the second stage regulator it should not flow 5 Listen for leaks at all hose connections 6 Don the facepiece 7 Connect the facepiece to the second stage regulator and in...

Страница 26: ...ation Specifica tion G 7 1 for Type 1 Grade D air having a moisture content expressed as dewpoint of 65 F or lower The cylinder shall be marked Fill With Compressed Air Only and shall meet applicable...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ...www sperianprotection com...

Отзывы: