background image

9

Panther HIP-PAC

All Facepieces

ii. Place your chin in the chin cup, pull the 
elastic adjustment strap over your head, and 
tighten by pulling evenly on both sides. See 
Figure 8.

iii. Center the facepiece and fasten the Head-

net with a wiping motion toward the back of 

your head.

iv. Retighten the elastic adjustment straps. Do 
not overtighten.
v. Perfo

rm a leak check as described below.

CAUTION

Do  not  adjust  the  fit  of  the  facepiece 

with the three locking straps at the top 

of  the  headnet.  Use  the  two  bottom 

straps only.

NOTE

When  properly  adjusted,  the  headnet 

should  be  centered  on  the  back  of  your 

head, and the lower straps should be below 
your ears.

c. Hood-Style Facepiece

WARNING

The SPERIAN hood-style facepiece:

• Must be worn in conjunction with an SAR 

and/or  SCBA  and  used  as  specified  in 

SPERIAN’s instructions.

•  When  donned  and  used  with  its  SAR/

SCBA,  will  reduce,  but  not  eliminate  the 

inhalation of contaminants.

• Does not protect against falling objects or 

projectiles.

 

• Must not be worn around open flames. It 

must not be used for structural fire fighting, 

underwater activities, or abrasive blasting.

• Must not be used unless a satisfactory fit 

is obtained.

• Must not be reused if contaminated.

• 

Must  not  be  altered  or  modified  in  any 

manner.

• Requires that the wearer must assure 

that the neck

  seal  is  not  compromised  by 

hair or clothing when in use.

• Requires that after each use and/or

cleaning and disinfecting, anti-fog solution 

(SPERIAN P/N 951015, 951016, OR 981805) 

must be applied to the inside of the lens.

• The Challenge® NXT, PVC lens, neoprene 

neck  seal,  and  adhesive  all  may  react 

in  a  different  manner  when  exposed  to 

chemicals or chemical mixtures. You must 

verify that none of the components of the 

hood will degrade against the chemicals or 
mixtures to which it may be exposed.

• It is vital to ensure that you have objective 

evidence  that  the  hood  will  be  able  to 

maintain its integrity against  the expected 
chemical exposure during operations. This 
can be accomplished by tests you conduct 

or  by  contacting  SPERIAN  for  further 

information. Listed below are a few, but not 

necessarily  all,  chemicals  that  are  known 

to  degrade  or  destroy  the  PVC  material. 

Do  not  use  the  hood  in  environments 

containing these chemicals:

• 

Acetone

•  Bleach 

•  Carbon tetrachloride

• 

Methanol

•  Methyl ethyl ketone

• 

Nitric acid

• 

Toluene

• 

Trichloroethylene

• Failure to comply with this warning may 

lead  to  serious  personal  injury,  serious 
illness, or death.

i. Fully loosen the suspension straps.

ii. Grasp the hood-style facepiece by the neck 

seal and pull the neck seal over your head.

iii. Position the nose cup on your face, then 
simultaneously tighten the two suspension 
straps.

D. Fit Check

WARNING

• Conduct fit checks only in a safe, un

-

contaminated environment.

•  Do  not  use  this  respirator  in  a  con

-

taminated  atmosphere  if  you  do  not 

obtain a satisfactory seal during the fit 

check. If a seal was not obtained, repo

-

sition  the  facepiece,  check  the  straps, 

and perform the fit check again. Failure 

to  obtain  a  satisfactory  seal  could  al

-

low contaminants to leak into the face

-

piece, causing illness or death. Failure 
to comply with this Warning may lead to 
serious personal injury, serious illness, 
or death.

WARNING—Continued

Figure 8. Adjust Headnet

Содержание Panther Hip-Pac 9649

Страница 1: ...D BREATHING APPARATUS P9684 SERIES 5 and 10 Minute Escape P9685 SERIES 15 Minute Escape P9686 SERIES HP 10 Minute Escape 9649 SERIES HP 10 Minute Escape OPERATION MANUAL WARNING DO NOT USE this respir...

Страница 2: ......

Страница 3: ...valve and pressure gauge assembly first stage regulator second stage regulator facepiece waist belt and regulator hose The cylinder stores 8 cubic feet of air at 2216 psig for the 5 minute apparatus...

Страница 4: ...st cannot be obtained See ANSI Z88 2 latest edition and OSHA 1910 134 Beards and side burns will prevent good facepiece seal Do not use this respirator unless you are clean shaven WARNING Continued Th...

Страница 5: ...ering the face piece and causing a severe reaction Do not use this respirator if you have been sensitized from previous exposure or believe that you may be sensitive or al lergic to any chemical until...

Страница 6: ...tacles Kit all 2020 Series Facepieces Wire Frame 964044 Spectacles Kit all 2020 Series Facepieces NexSpex B140095 Lens Cover Clear Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 L...

Страница 7: ...Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 Lens Cover Clear TwentyTwenty Plus 951015 Anti fog Solution 1 oz 951016 Anti fog Solution 16 oz 981805 Anti fog Wipes Box of 100 B14...

Страница 8: ...rator hose This operation requires a torque wrench WARNING Carefully inspect and clean all threads to remove foreign material Foreign ma terial entering the air line can restrict or block air flow to...

Страница 9: ...turned on while connect ed to the air supply will cause loss of air in the cylinder resulting in reduced es cape time in case of an emergency Always disengage the regulator from the facepiece and ret...

Страница 10: ...operly on the face and the regulator installed and activated Failure to comply with this Warning may lead to serious personal injury se rious illness or death 16 There are two methods depending upon w...

Страница 11: ...ens The Challenge NXT PVC lens neoprene neck seal and adhesive all may react in a different manner when exposed to chemicals or chemical mixtures You must verify that none of the components of the hoo...

Страница 12: ...tons when installing the regulator WARNING Rotate and tug the regulator to ensure that both release buttons are properly engaged in the AIR KLIC Do not push the release buttons while verifying the eng...

Страница 13: ...eathing exhale forcefully The regulator should return to normal flow b If the free flow continues open and close the by pass once or depress the manual override button once c If the problem persists I...

Страница 14: ...water and a mild detergent 2 Fully immerse the facepiece in the solution 3 Agitate the facepiece and gently clean with a soft brush 4 Thoroughly rinse the facepiece in fresh water paying particular a...

Страница 15: ...cleaning may require reapplication of anti fog coating to the facepiece lens Use only SPERIAN Anti Fog Solution P N 951015 1 oz or P N 951016 16 oz 6 After cleaning three drops of anti fog solution m...

Страница 16: ...ly rinse the exterior surfaces and the interior of the outlet tube with fresh water Scrub excess soap away with the brush 5 Dry with a clean cloth or with low pressure 15 psig maximum clean breathing...

Страница 17: ...F Cylinders damaged by fire or exposed to heat of 350 F must be destroyed Repainted or refinished cylinders must be hydrostatically tested before reuse WARNING Continued Do not fill a composite cylind...

Страница 18: ...l be maintained at 65 F 53 9 C or lower or less than 24 0 ppm by volume moisture content UNDER NO CIRCUM STANCES SHALL AN AIR CYLINDER BE FILLED OR PARTIALLY FILLED WITH OXYGEN b Maximum Fill Pressure...

Страница 19: ...cold weather problems however cold weather condi tions may also cause other problems not listed below 1 Air Supply NOTE Cold weather conditions require very dry air Moisture entering the HIP PAC may...

Страница 20: ...e and regulator until the normal function of the AIR KLIC button and or the shutoff button returns j Should ice form on the regulator while the regula tor is in the regulator receiver rotate the regul...

Страница 21: ...tures especially if there is ice d Use HIP PAC accessories with extreme care in cold weather conditions Visually inspect them pe riodically for ice J Storage Inspect clean and repair as required befor...

Страница 22: ...placement or repair of defective parts and such other necessary maintenance and repair as may be required Normal wear and tear and parts damaged by abuse misuse negligence or accidents are specificall...

Страница 23: ...k seal to tear SECOND STAGE REGULATOR AND HOSE 1 Cracks or heat damage to housing or cover 2 Faulty operation of bypass valve First Breath On AIR KLIC or override buttons 3 Dirt and debris in the outl...

Страница 24: ...remove the rim nuts and screws 2 Gently separate the rims from the facepiece 3 Pull the silicone skirt away from the lens 4 Remove the old lens 5 Match one corner of the new lens with a corner of the...

Страница 25: ...disconnect nipple 4 Listen to the second stage regulator it should not flow 5 Listen for leaks at all hose connections 6 Don the facepiece 7 Connect the facepiece to the second stage regulator and in...

Страница 26: ...ation Specifica tion G 7 1 for Type 1 Grade D air having a moisture content expressed as dewpoint of 65 F or lower The cylinder shall be marked Fill With Compressed Air Only and shall meet applicable...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ...www sperianprotection com...

Отзывы: