Datalogging IAQ Meter
800050
Instruction Manual
Страница 1: ...Datalogging IAQ Meter 800050 Instruction Manual ...
Страница 2: ... The contents of this manual may not be reproduced or transmitted in any form or by any means electronic mechanical or other means that do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permission from Sper Scientific ...
Страница 3: ...RES 9 7 SOFTWARE INSTALLATION 13 8 RUNNING THE SOFTWARE 15 9 DATALOGGER SETTINGS 16 Setting Options 16 Comm Port Setting 16 Basic Logger Setting 17 Logger Alarm Sensor Setting 18 Logger Sampling Setting 18 Setting Start Modes 19 10 DATA SAMPLING AND RECORDING 21 11 DOWNLOADING DATA 23 12 TROUBLESHOOTING 26 13 SPECIFICATIONS 27 14 WARRANTY 28 ...
Страница 4: ...4 ...
Страница 5: ...spitals and hotels Recalls the maximum and minimum CO2 readings and has a user selectable audible maximum alarm Automatic Baseline Calibration ABC and maintenance free NDIR non dispersive infrared CO2 sensor ensure long term accuracy stability and reliability Calibrates to air and has a hold function Records up to 32 000 data points of temperature RH and CO2 that can be downloaded using a USB cabl...
Страница 6: ...dings User selectable audible maximum alarm Calibrates to air Hold function Records up to 32 000 data points of temperature RH and CO2 Tripod mounting screw MATERIALS SUPPLIED Datalogging IAQ meter CD USB Driver and Logger Software USB Connector Cable AC Adapter Carrying Case Instruction Manual ...
Страница 7: ...2 LCD Display 3 Hold Button 4 Mode Button 5 Power Button 6 Max Min Button 7 Set Button 8 Unit Button 9 Adjust Button Key Start 10 Battery Compartment on back not pictured 11 USB Driver Datalogging Software CD 1 2 11 3 4 5 6 7 8 9 ...
Страница 8: ... ABC is designed for test areas that receive fresh air with a CO2 level of 400 ppm at some point during fifteen days of metering If the meter is being used in a closed area with consistently high levels of CO2 the meter should be calibrated manually MANUAL CO2 CALIBRATION Note Manual calibration is not recommended unless the unit can be kept in a 400 ppm CO2 environment for at least 12 hours 1 Set...
Страница 9: ...er close to any source of CO2 Note Measurement response time is 10 seconds for CO2 and 2 seconds for RH If the operating environment changes it takes approximately 30 seconds for the CO2 sensor to respond and 30 minutes for the RH sensor to stabilize 1 Turn the meter ON by pressing PWR 2 The meter will warm up briefly and the reading will be displayed Due to the CO2 NDIR sensor it takes approximat...
Страница 10: ...iew the minimum and maximum readings while in Normal Mode 1 Press MAX MIN to display the maximum reading 2 Press MAX MIN again to display the minimum reading 3 Press MAX MIN to return to Normal Mode To reset the minimum and maximum readings 1 With the minimum or maximum reading displayed press HOLD for 2 seconds 0 will display 2 Press MAX MIN to return to Normal Mode Hold Function 1 Press HOLD to ...
Страница 11: ...ODE again to return to viewing RH Temp Auto Power Off The meter will automatically turn off after 15 minutes if there has been no use To disable the auto power off function do the following 1 Turn the meter OFF 2 Press and hold the HOLD button 3 While holding down HOLD press PWR to turn the meter on The letter n will show on the screen and the meter will turn on Note Every time you turn the meter ...
Страница 12: ...ton to move to the left digit 5 Press the MAX MIN button to move to the right digit 6 Press and hold SET to save the changes screen will flash SAVE and then return to normal Note When the CO2 alarm is on the bell icon will show next to the CO2 reading When the threshold has been reached the audible beeping will commence To turn the CO2 alarm OFF quick press PWR The bell icon will disappear indicat...
Страница 13: ... PL2303_Prolific_Driverinstaller_v110 5 Select yes to allow the program Setup exe to make changes to your computer 6 The PL 2303 Driver Installer program opens Select Next to start the installation 7 Select Finish to complete the driver installation Now you can install the logger software Installing the Logger Software from Website You can now download the software that came with your meter direct...
Страница 14: ...the disc 9 Double click to select Datalogger_Products Software 10 Double click again to open the folder 11 Double click to select Setup Type Application 12 Select yes to allow the program Setup exe to make changes to your computer 13 The Destination Directory appears This lists the target directories for the datalogger and software Select Next 14 Read the license agreement and select I accept the ...
Страница 15: ...he USB port on your computer 3 Open the Start Menu and select the Data Logger Icon from the programs list 4 The USB Data Logger Meter screen displays Note The meter should be plugged into the USB port before the software is opened If the meter is not plugged into the correct port an error message will appear Make sure that the meter is plugged in correctly ...
Страница 16: ...hardware content click Device manager to find the listed COMx listed under Ports COM LPT as below with red line If you may Prolific USB to Serial Comm Port it means the logger is connected to computer properly 2 Remember the Comm port number and go back to software 3 Click Setting Comm port select the port number as you see from step 1 then press OK button Logger Setting 98536 98537 98538 98539 on...
Страница 17: ...ogger and specify the current date and time 1 Select Log Setting from the Setting options The Logger Setting menu displays 2 Select the Basic tab 3 Enter a name for your logger consisting of up to 20 characters 4 Select OK to save your entry 5 The system will automatically show the current computer date and time Select OK to save your entry and sync the meter s current date and time Manual set COM...
Страница 18: ...ger Sampling Setting 4 Select the Setting tab 5 The meter sampling range is 1 second to 6 59 59 Adjust the or indicators to specify the sampling rate in hours minutes and seconds 6 Adjust the or indicators to select Immediate Roll Over or Schedule start mode Pic 1 Pic 2 Manual set COM port If software message box shows as Pic2 Follow the steps below 1 Click My computer Content in hardware content ...
Страница 19: ...Select Ok to save the settings and exit the menu or Cancel to exit without saving the new settings Setting Roll Over Mode This option allows for continued recording even when the meter is full After the data limit has been reached new readings will be recorded over the earliest previous record 1 Adjust the or indicators to specify the number of sample points in thousands from 1000 to 32 000 2 Adju...
Страница 20: ... or F 3 The fields for the start date and time and the stop date and time will be automatically populated with default values Click on any of these fields and use the computer keyboard to make changes as desired 4 Select Ok to save the settings and exit the menu or Cancel to exit without saving the new settings Setting Key Start Mode 1 Adjust the or indicators to specify the number of sample point...
Страница 21: ...nd meter Recording will continue 3 Place the meter in the desired location for sampling 4 The datalogger will record up to 32 000 data points Once the memory is full recording will stop Sampling and Recording in Roll Over Mode 1 The green LED will flash to indicate that the meter is recording data 2 Disconnect the USB cable from the computer and meter Recording will continue 3 Place the meter in t...
Страница 22: ... and time are reached recording will stop Sampling and Recording In Key Start Mode 1 Disconnect the USB cable from the computer and meter Place the meter in the desired location for sampling 2 At the desired start date and time press and hold the Key Start Button for 3 5 seconds The green LED will flash to indicate that the logger has started recording data 3 The datalogger will record the number ...
Страница 23: ...meters and rate will display 6 Click the Download button to download the data A graph of the data will display Viewing the Graph Note To display the values for a specific data point click the left mouse button to move the red cursor located on the red vertical line to the desired point on the graph You may also hold down the left mouse button and drag the cursor to the desired point To zoom in Hol...
Страница 24: ...ar to the left of one of the data parameters under the graph Temp Humidity Dew Point or Wet Bulb b Move the mouse to select a new color and click on it c The selection will be saved and the graph size will return to the default Printing the Graph 1 Click the Printer Icon button to print the graph 2 Click OK to confirm the selection ...
Страница 25: ...nter the record range you wish to print for example 1 2 350 or leave the field blank to print all the records 4 Click OK to confirm your selection 5 Click OK to start printing Saving the Data 1 Click the Save button floppy disc icon to save the data 2 Enter a unique name for the file 3 Click OK to confirm Retrieving Stored Files 1 Click the File button open folder icon 2 Select the file you want t...
Страница 26: ...ould cause malfunctions which require service Error Code Description E 1 Temperature or Humidity sensor is damaged or sensor communication is error E 2 Readings exceed Temp RH specifications out of range 9999 Readings exceed CO2 max range or the batteries are weak ...
Страница 27: ...IFICATIONS Range Res Accuracy Temperature 10 to 50 C 0 1 C 1 C 14 to 122 F 0 1 F 2 F RH 10 to 90 0 1 5 25 C CO2 0 to 9999 ppm 1 ppm 75 ppm 5 of rdg 0 to 5000 ppm Dimensions 8 2 2 210 57 51 mm Weight 7 oz 198 g ...
Страница 28: ...lable This warranty does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 E Evans Rd Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a description of the p...