24
Installation
Vorsicht
Risk of injuries
The user may be injured by damaged components.
►
Do
not
mount the charging station:
–
near to flammable materials.
–
In the potentially explosive areas.
–
in salty or wet surroundings.
–
in the vicinity of aggressive vapours.
–
in surroundings which are exposed to permanent vibrations.
These types of surroundings include, e.g. outdoor areas around petrol stations, chemical
factories, waste disposal sites, sewage treatment plants.
Achtung
Risk of damage caused by the influence of weather
The charging station can be damaged by the incorrect choice of location.
►
Do not expose the charging station to any heat sources (e.g. sun radiation, heating).
►
Mount the charging station at a location that is protected against rain and splash water
(for example, in protected outdoor areas, Abb. 2).
Risk of damage from drilling
Parts of the installation may be damaged by incorrect drilling.
►
Before carrying out drilling work on the wall / mounting area, make sure that no electric
cables or other lines can be damaged by drilling.
Figure 2:
Installation in protected
outdoor areas
When choosing the assembly location, please observe the following:
Only mount the charging station vertically (e.g. on the building walls).
The assembly area must be level and have a sufficient strength.
The free distance around the charging station must be at least 250 mm.
This also applies to the growth of green plants.
The distance to other charging stations must be at least 1,400 mm.
The distance to another obstacle must be at least 700 mm.
The upper edge of the charging station must be located 1,400 to 1,600 mm above the ground.
During operation, the charging station must always be provided with sufficient lighting.
If necessary, install lighting.
The following special tools are required for assembly:
Screwdriver (for fastening without external fixing brackets with a blade length of at least 175 mm)
Cover opening tool 8 mm triangle (in the scope of delivery)