![Spellman XLF SERIES Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/spellman/xlf-series/xlf-series_instruction-manual_1346483021.webp)
XLG/XLF MANUAL
14
118020-001 REV E
2
JB1
General Purpose
12Vdc lamps or relay coils may replace opto-couplers.
1
R Limit
Opto-couplers, lamps or relays should be located as close
as possible to the high voltage power supply.
All cables should be shielded with the shields being returned
to chassis ground of the High Voltage Power Supply.
To High Voltage
OFF Indicator
3
4
Opto-Coupler
PS Common
7
6
5
10
11
13
12
9
8
14
18
16
17
15
R Limit
General Purpose
Opto-Coupler
To High
Voltage
Indicator
ON
Signals are 15Vdc, 10mA max.
R Limit must be > 500 Ohms.
1/4 W
1K Ohm
1/4 W
1K Ohm
P/O High Voltage
Power Supply
Figure 3.8 Remote High Voltage ON and Remote High Voltage OFF Indicator Circuit