XLG/XLF MANUAL
11
118020-001 REV E
3
4
V
Program
Voltage
6
7
Z in = 10M Ohms
via isolation amplifiers.
All cables should be shielded with the shields
being returned to the chassis ground of the
High Voltage Power Supply.
9
8
10
11
Remote
Remote
Program
Current
Z in = 10M Ohms
Voltage Source 0-10V = 0-100% of Rated Output
Remove jumpers for
remote programming
1
JB1
v
PS Common
It is recommended that analog signals be isolated
5
2
Figure 3.3A Wiring Diagram for Remote Programming Via Voltage Source
1
JB1
PS Common
Fully Counterclockwise = Zero Output
5
2
3
4
6
7
Z in = 10M Ohms
All cables should be shielded with the shields
being returned to the chassis ground of the
High Voltage Power Supply.
9
8
10
11
Remote
Control
Current
Z in = 10M Ohms
Remove jumpers for
remote programming
20k Ohm
1mA max.
+10.32V
CW
20k Ohm
CW
Voltage
Control
Remote
Fully Clockwise = 100% of Rated Output
If connections to external potentiometers are
excessively long (>10 ft), motorized
potentiometers are recommended.
Figure 3.3B Wiring Diagram for Remote Programming Via External Resistance