XLG/XLF MANUAL
10
118020-001 REV E
JB1 SIGNAL
SIGNAL
PARAMETERS
1
Power Supply Common
Signal Ground
2
External Inhibit
Ground = Inhibit, Open = HV ON
3
External Interlock
+15V at Open, <15mA at Closed
4
External Interlock Return
Return for Interlock
5
Current Monitor
0 to 10V = 0 to 100% rated output
6
KV Test Point
0 to 10V = 0 to 100% rated output
7
+ 10V Reference
+10.24V, 1mA max.
8
Remote Current Program In
0 to 10V = 0 to 100% rated output
9
Local Current Program Out
Front Panel Program Voltage
10
Remote Voltage Program In
0 to 10V = 0 to 100% rated output
11
Local Voltage Program Out
Front Panel Program Voltage
12
Power Monitor
0 to 10V = 0 to 100% rated output
13
Remote Power Program In
(Optional)
14
Local HV OFF Out
+15V at Open, <25mA at Closed
15
HV OFF
Connect to HV OFF for FP operation.
16
Remote HV ON
+15V, 10mA max = HV ON
17
Remote HV OFF Indicator
0 = HV ON, +15V, 10mA max = HV OFF
18
Remote HV ON Indicator
0 = HV OFF, +15V, 10mA max = HV ON
19
Remote Voltage Mode
Open Collector 50V max, 10mA max,
20
Remote Current Mode
On = Active
21
Remote Power Mode
22
Remote PS Fault
0 = Fault, +15V, 1mA max = No Fault
23
+ 15V Output
+15V, 100mA max
24
Power Supply Common
Signal Ground
Table 3.1 Rear Panel Interface