SLS SERIES MANUAL
13
118132-001 RevA
It is recommended that analog signals be
isolated via isolation amplifiers. All cables
should be shielded with the shield being
returned to the chassis ground of the high
voltage power supply.
Figure 3.3 -- Remote Monitor Test Points
S1 must be closed to enable HIGH VOLTAGE.
Momentary closure of S2 will enable HIGH
VOLTAGE ON.
Opening S1 will disable HIGH VOLTAGE ON and
switch the unit to the HIGH VOLTAGE OFF mode
.
It is recommended to use relay contacts for S1 and
S2. Relays should be located as close as possible to
the high voltage power supply. Coils should be
driven from isolated sources. Signals are at 15Vdc,
25mA max., and are only to be used for contact
closure.
Figure 3.4 Remote Control Of High Voltage On and
High Voltage Off Interface