3.3.5.
Scintillator Output and Cables
This uses a bespoke
’Poke home’ receptacle
manufactured by Spellman HV with an 9mm ISO metric
thread, 39mm deep. See drawing in Appendix 3
Different lenghts scintillator mating cables
for the ‘Poke home’
receptacle are available to order.
Scintillator Cable Assembly part number Cable Length
HVC11/1SO/1320
1m
HVC11/1SO/1316
2m
3.3.6.
PMT and Collector Outputs
These outputs use an industry standard BNC.HT connector (i.e. Radiall R316 553)