EN
13
Bubble Level
Foam Blade
Holder
Binding with Optional Second Remote Receiver
1. Remove the telemetry remote cable from the BND/PRG/RX2 port.
2. Insert a bind plug into the BND/PRG/RX2 port.
3. Power ON the FC6250HX, the orange LED on the remote receiver will
begin to flash to indicate it is in bind mode.
4. Leave power connected and remove the bind plug.
5. Reconnect the telemetry remote cable to the BND/PRG/RX2 port and press
the bind button on the telemetry remote receiver. The orange LED on the
telemetry remote will flash when it enters bind mode. Release the bind
button.
6. Put your transmitter into bind mode. The Orange LED on the remotes will
remain lit when the bind is successful.
Repeat the process if necessary.
1. Level the model using a bubble level on the roll and pitch axis, power on and
initialize the system.
2. Go to the
System Setup
menu and select
Calibrate
.
3. Select
Apply
.
A red flashing light during calibration indicates the model is either not level
or not stationary. Level the model, taking care to keep it still.
A yellow flashing light during calibration indicates the calibration is
proceeding normally.
4. After the calibration is successful, the LED flashes green.