Parameter setting

Hotel power-up

 

scene

 

function

when  the  guest  enters

 

room

 

and  inserts  the  card  for 

power,  the  air  conditioning  system  will  automatically 
enters into its  status.

   

1

 

Set

 

up

 

temperature

 

and

 

wind

    speed for the room.

2

 

Press the SET

 

button

 

on the remote

  

then the touch screen will flash

.

3

 

Press the ON

/

OFF

 

button

 

  

on

 

touch

 

screen

4  Finally, press SET

 

button

 

to

 

finish the

    power-up

 

scene

.

Lock

 

setting

This  system  has

 

special

 

lock  function  to  facilitate

 

its

 

management

It

 

will

 

lock

 

the

 

system

 

if necessary.

Lock:  The  lock  function  can  be  achieved  only  with  the  remote  controller.  Press  the

 

SET

 

button

 

once

 

at

 

first

then

 

press

 

the

    

button

 

to lock the system.

Unlock: the unlock function can also be achieved only with the remote controller.

 

Press

  

on

 

the

 

remote

 

controller

 

and

 

unlock the system.

Note: if the power is off

this setting

 

will

 

be

 

canceled. 

Timing Setting 

This function can be achieved air conditioning timing switch.

 

Press

 

SET

 

button twice, the 

minute digits flash

then

 

press

 

the HOUR

 

button

the hour digits will display 88:

 

flash

set

 

up

 

the

 

time

 

with       &       button

If the device is shut down within 15 second  

afer 

setting

 

it

 

will

 

restart

 

on

 

the

 

setting

 

time

If

 

the

 

device continues

 

the operation after 

setting

 

time

it

 

will

 

shut

 

down

 

on

 

the

 

end of setting

 

time

 (

customized.

)

Close-fitting service

Professional user

 

can

 

edit

 

timing

 

setting

and then the air conditioning system will run in

 

accordance with the temperature setting and time setting,

 

this shall save time and energy

but

 

this

 

is

 

paid

 

service

Please contact local agent or our company

 

for

 

detail

.

Содержание SK-AC2000

Страница 1: ...the manual before using the product Please preserve properly for future reference PRODUCT 2 0 0 8 SK AC2000 USER MANUAL Electric Room Thermostat www speed key com SPEEDKEY TECHNOLOGY CO LTD SPEEDKEY TECHNOLOGY CO LTD ON OFF SPEED ...

Страница 2: ... 65mm 50mm Its external dimensions of the touch panel is 86 mm 86mm 18mm which shall be connected to the host with 6 core cables SK AirC Remote Infrared remote controller With infrared transmitter in this remote controller its operating range is more than 15m in free space its remote control angle is less than or equal to 90 degrees and the infrared ray can be reflected indoors PROPER POSITIONS FO...

Страница 3: ...ON OFF SPEED CR2025button cell SK AirC Remote Controller of 2 fixing screws 速 度 开 关 ON OFF SPEED HOUR MIN SET DOWN DEFAULT UP YEAR MONTH DAY Remote for staff only ON OFF HIGHT LOW MID MODE HEAT COOL Electric Room Thermostat detachable SK AC2000SYS Controller panel Host of the controller Fixed bracket Manual SK AirC Remote Controller of CR2025 button cell 2 fixing screws PRODUCT 2 0 0 8 SK AC2000 O...

Страница 4: ...ate clearly in any environment even it is dark Its intelligent circuit control has 3 steps of wind speed control there are 3 optional modes which is cooling mode heating mode and automatic mode can be set by infrared remote SK AC2000 can replace traditional mechanical air conditioning temperature controller and it can effectively save more than 30 energy Electric Room Thermostat Electric Room Ther...

Страница 5: ...el valve control neutral line output earthing line output earthing line input Neutral line input 100 200V AC live line input Air conditioning touch control panel 6 bit control terminals Fan coil Cooling and heating water valve Electric Room Thermostat see figure detachable SK AC2000SYS NSR Single valve circuit diagram 6 bit control terminals weak current control connection wire Host for air condit...

Страница 6: ... 200V AC live line input Fan coil Cooling water valve heating water valve detachable SK AC2000SYS SR Double valve circuit diagram see figure Electric Room Thermostat Remark SR s self elastic spring valve can close automatically when the power is off Air conditioning touch control panel 6 bit control terminals 6 bit control terminals weak current control connection wire Host for air conditioner con...

Страница 7: ... circuit 2 Open the switch base box of touch screen panel with the screwdriver Dismounting hole 3 Check Bs4662 switch base box whether there is enough space 50mm to install touch screen switch If the space is not enough the thickening bracket shall be used 4 Draw out strong electric cable and network cable from Bs4662 switch base box and trim up press tightly on terminal block as illustration Wiri...

Страница 8: ...erminal Connecting method of screw terminall Please use single wire of diameter of 1 6 or 2 0 to comply with non screw terminals suitable cable Please use single or multi copper wire of diameter less than 4mm to comply with screw terminals suitable cable 5 Mount the switch driving section into base box and fix with 2 screws 6 Insert the wiring terminal of switch driving section into the touch scre...

Страница 9: ... 关 ON OFF SPEED 速 度 开 关 ON OFF SPEED 7 Cover the touch screen panel 8 Set program setting as you like Illustration for installation of detachable SK AC2000SYS Electric Room Thermostat SK AC2000T air conditioning control panel bracket wall BS4662 switch base box 6 cored cable SK AC2000M air conditioning controller strong current cable fan coil Fix the host beside the fan coil controller ...

Страница 10: ... the function of timing and advanced time setting EEPROM can permanently keep parameters set by the user during power cut Various valves SR NSR can be controlled It can save effectively more than 30 energy SK AC2000 intelligent is suitable for installation in standard Bs4662 switch base box Electric Room Thermostat Introduction of SK AC2000 display screen Heating mode Cooling mode Operating status...

Страница 11: ...estarts The system will automatically affirm the setting in LCD screen and display the corresponding static icon Cooling mode the system cooling setting must be set up with the remote controller Press MODE button and press button and set summer cooling mode Its default temperature is 26ºC when this system restarts The system will automatically affirm the setting of LCD screen and display the corre...

Страница 12: ...tion to facilitate its management It will lock the system if necessary Lock The lock function can be achieved only with the remote controller Press the SET button once at first then press the button to lock the system Unlock the unlock function can also be achieved only with the remote controller Press on the remote controller and unlock the system Note if the power is off this setting will be can...

Страница 13: ...ontrolled equipments No shut off of air conditioner Ceaseless Flash fo r touch screen Possible cause Solutions 1Incorrect wiring or poor contact 2 Main switch or creepage protection switch is off 3 No neutral line connected of the system 4 Burnt fuse 5 Auto protection of the system 1 Unstable Voltage too much interference 2 Incorrect wiring 3 Shut by remote controller 1 Overload current 1 Broken o...

Страница 14: ...SPEEDKEY TECHNOLOGY CO LTD Specifications subject to change without notice 2008 All rights reserved www speed key com ...

Отзывы: