SPEEDKEY

18

SPEEDKEY

SK-AC2000

SK-AC2000

Electric Room

 

Thermostat

Electric Room

 

Thermostat

PRODUCT

 

DESCRIPTION

HOU R

MIN

SET

DOWN DEFAULT

UP

YEAR

MONTH

DAY

T

IM

E

D

A

T

E

Remote for staff only

 ON/OFF

T

E

M

P

HIGH

LOW

MID

S

P

E

E

D

MODE

HEAT

COOL

mode button

PARAMETER SETTING

SK-AC2000 Remote explanation

SET button

 

On

/

Of button

 

Minute setting

Hour setting 

date setting

 heating button

 

Default button

 

DOWN button

Signal transmitting terminal

Touch screen unlock key

Touch screen lock key

Cooling button

low,medium, high 
speed setting button 

up button

When  the  touch  screen  is  pressed,  the  corresponding  indicator  will  be  lighted

.               

The

 

touch

 

screen

 

and

 

LCD

 

screen

 

will

 

automatically

 

enter

 

dim

 

backlight

 

mode

 

if

 

no

 

operation

 

in

  15 

seconds

The  system  control  and  setting  can  be  achieved 

completely via the

 

remote

 

controller

Some

 

special

 

functions

 

have

 

to

 

be

 

achieved

 

only

 

by

 

the

 

remote

 

control

.

Note:

Time setting: the system must be set up with remote controller. Press SET button on the remote at first, and 

then  press  HOUR  button  and  set  up  the  hour,and  then  press  MIN  button  and  set  up  minute. 

Date setting:  the date setting must be set up with remote controller. Press SET button on the remote at first, 

and  then  press  YEAR  button  and  set  up  the  year

;

then  press  MONTH  button  and  set  up  the 

month

Press the DAY button and set up the day 

(

customize

).

Heating mode:

the  system  must  be  set  up  heating  setting  with  the  remote  controller.  Press  MODE 
button, and press     button

 

and

 

set

 

winter

 

heating

 

mode

The default temperature 

is 

2 0

º

C  when  this system restarts. The  system will  automatically affirm the  setting  in

 

LCD

 

screen

 

and

 

display

 

the

 

corresponding

 

static

 

icon

.

Cooling mode: 

the system cooling setting must be set up with the remote controller. Press MODE button,

 

and

 

press 

   

button

 

and

 

set

 

summer

 

cooling

 

mode

Its

 

default

 

temperature

 

is

 

2 6

º

C when this 

system  restarts.  The  system  will  automatically  affirm  the  setting  of  LCD  screen  and  display 
the corresponding static icon.

Auto mode:

 

Press MODE button twice, the system shall enter into the auto mode, and LCD screen

 

will 

display     

  

 

icons. When the setting temperature is higher than room temperature, its mode 

is  heating

 

mode

when

 

the

 

setting

 

temperature

 

is

 

lower

 

than

 

room

 

temperature

its

 

mode

 

is

 

cooling

 

mode

and  thus  it  can  achieve  auto  constant  temperature 

(

Two  valves 

must be installed for auto mode, namely

cooling valve and heating valve). 

Note: 

if  the  icon  flashes  during  system  operation,  it  means  the  valves

 

are

 

open

,     

flash

 

means

 

heating

and

    

flash means cooling.

Note: 

 

S

ome

 

advanced

 

system

 

can

 

be

 

set

 

up

 

the

 

year

month

 

and

 

day

 

setting with

  remote controller.

This  feature  can  prevent  the  relay  to  start  in  the  setting  time,  the  default  settings

 

is

 

zero

 

(

the

 

relay

 

only

 

changes

 

as the temperature

 

changes

) .

Adjust minimum relay 

closing time with remote controller, press SET button twice, and use the      &     button 
on the panel to set the minimum relay closing time from 0-15 minutes when the Minute 
indicator flashes on touch screen.

When the room temperature drifts, correct the deviation of 

± 2 

º 

C

 

with

 

the

 

remote

 

controller

press the SET button three times , use the      &     

 

button

 

and

 

correct

 

the

 

deviation

(

increase

 

or

 

decrease

 

2)

 

when

 

the

 

temperature

 

display

 

flashes

 

on

 

touch

 

panel

Minimum relay 
closing time setting:

Room temperature 
drift correction :

Содержание SK-AC2000

Страница 1: ...the manual before using the product Please preserve properly for future reference PRODUCT 2 0 0 8 SK AC2000 USER MANUAL Electric Room Thermostat www speed key com SPEEDKEY TECHNOLOGY CO LTD SPEEDKEY TECHNOLOGY CO LTD ON OFF SPEED ...

Страница 2: ... 65mm 50mm Its external dimensions of the touch panel is 86 mm 86mm 18mm which shall be connected to the host with 6 core cables SK AirC Remote Infrared remote controller With infrared transmitter in this remote controller its operating range is more than 15m in free space its remote control angle is less than or equal to 90 degrees and the infrared ray can be reflected indoors PROPER POSITIONS FO...

Страница 3: ...ON OFF SPEED CR2025button cell SK AirC Remote Controller of 2 fixing screws 速 度 开 关 ON OFF SPEED HOUR MIN SET DOWN DEFAULT UP YEAR MONTH DAY Remote for staff only ON OFF HIGHT LOW MID MODE HEAT COOL Electric Room Thermostat detachable SK AC2000SYS Controller panel Host of the controller Fixed bracket Manual SK AirC Remote Controller of CR2025 button cell 2 fixing screws PRODUCT 2 0 0 8 SK AC2000 O...

Страница 4: ...ate clearly in any environment even it is dark Its intelligent circuit control has 3 steps of wind speed control there are 3 optional modes which is cooling mode heating mode and automatic mode can be set by infrared remote SK AC2000 can replace traditional mechanical air conditioning temperature controller and it can effectively save more than 30 energy Electric Room Thermostat Electric Room Ther...

Страница 5: ...el valve control neutral line output earthing line output earthing line input Neutral line input 100 200V AC live line input Air conditioning touch control panel 6 bit control terminals Fan coil Cooling and heating water valve Electric Room Thermostat see figure detachable SK AC2000SYS NSR Single valve circuit diagram 6 bit control terminals weak current control connection wire Host for air condit...

Страница 6: ... 200V AC live line input Fan coil Cooling water valve heating water valve detachable SK AC2000SYS SR Double valve circuit diagram see figure Electric Room Thermostat Remark SR s self elastic spring valve can close automatically when the power is off Air conditioning touch control panel 6 bit control terminals 6 bit control terminals weak current control connection wire Host for air conditioner con...

Страница 7: ... circuit 2 Open the switch base box of touch screen panel with the screwdriver Dismounting hole 3 Check Bs4662 switch base box whether there is enough space 50mm to install touch screen switch If the space is not enough the thickening bracket shall be used 4 Draw out strong electric cable and network cable from Bs4662 switch base box and trim up press tightly on terminal block as illustration Wiri...

Страница 8: ...erminal Connecting method of screw terminall Please use single wire of diameter of 1 6 or 2 0 to comply with non screw terminals suitable cable Please use single or multi copper wire of diameter less than 4mm to comply with screw terminals suitable cable 5 Mount the switch driving section into base box and fix with 2 screws 6 Insert the wiring terminal of switch driving section into the touch scre...

Страница 9: ... 关 ON OFF SPEED 速 度 开 关 ON OFF SPEED 7 Cover the touch screen panel 8 Set program setting as you like Illustration for installation of detachable SK AC2000SYS Electric Room Thermostat SK AC2000T air conditioning control panel bracket wall BS4662 switch base box 6 cored cable SK AC2000M air conditioning controller strong current cable fan coil Fix the host beside the fan coil controller ...

Страница 10: ... the function of timing and advanced time setting EEPROM can permanently keep parameters set by the user during power cut Various valves SR NSR can be controlled It can save effectively more than 30 energy SK AC2000 intelligent is suitable for installation in standard Bs4662 switch base box Electric Room Thermostat Introduction of SK AC2000 display screen Heating mode Cooling mode Operating status...

Страница 11: ...estarts The system will automatically affirm the setting in LCD screen and display the corresponding static icon Cooling mode the system cooling setting must be set up with the remote controller Press MODE button and press button and set summer cooling mode Its default temperature is 26ºC when this system restarts The system will automatically affirm the setting of LCD screen and display the corre...

Страница 12: ...tion to facilitate its management It will lock the system if necessary Lock The lock function can be achieved only with the remote controller Press the SET button once at first then press the button to lock the system Unlock the unlock function can also be achieved only with the remote controller Press on the remote controller and unlock the system Note if the power is off this setting will be can...

Страница 13: ...ontrolled equipments No shut off of air conditioner Ceaseless Flash fo r touch screen Possible cause Solutions 1Incorrect wiring or poor contact 2 Main switch or creepage protection switch is off 3 No neutral line connected of the system 4 Burnt fuse 5 Auto protection of the system 1 Unstable Voltage too much interference 2 Incorrect wiring 3 Shut by remote controller 1 Overload current 1 Broken o...

Страница 14: ...SPEEDKEY TECHNOLOGY CO LTD Specifications subject to change without notice 2008 All rights reserved www speed key com ...

Отзывы: