background image

CAUTION!

             

Before commencing any work on the electrical 

connections, you must first disconnect the device from 
the mains. None of the 230V connections must  be live 
until the installation has been completed and the housing 
is closed. Only qualified electricians or authorised service 
staff are permitted to open the terminal box.
There are parts that carry mains voltage behind the cover. 
The terminal box must not be left unsupervised when 
open. (Prevent non specialists and especially children 
from gaining access to it.)
Ensure that this wireless enabled programmer is installed 
1 Metre from any metalic object, television, radio or 
wireless internet transmitter.

Operating Instructions

Page 1 of 2

RFRB - RF Room Thermostat

4.  Installation

1.  Factory default settings

6. Resetting the thermostat

7.  On / Off function

2.  Specifications & wiring

Temperature indicator: 

°C

Switching differential:  

0.2°C

In built frost protection: 

5°C

Keypad lock: 

  

Off

3.  Mounting

     

 Contents 

1.  Factory default settings

2.   Specification & wiring

3.   Mounting

4.   Installation

5.   Button / symbol description

6.   Resetting the thermostat

7.   On / Off function

8.  Lock function

9.   To connect the RFRB thermostat to the

 

R_7-RF programmer

10.  To disconnect the RFRB thermostat from 

 

the R_7-RF programmer

Prior to setting the thermostat, it is neccessary to complete all required settings described in this 

section.

5.  Button / symbol description

Important: Keep this document

Power Supply: 

 

2 x AAA Alkaline Battery 

Power consumption:   

50 uA

Battery replacement:   

Once per year

Temp. Control Range:   

5...35°C

Dimensions:  

 

84 * 84 * 30mm

Temp. sensor:  

 

NTC 10K Ohm @ 25°C

Temp. indication:  

 

°C

   

The mounting height should be 1.5 meters above the floor level. The 
thermostat should be wall mounted in the room where the heating is to 
be controlled.
The place of installation should be chosen so that the sensor can measure 
the room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or 
other heating / cooling sources when mounted.
The unit can be fitted to: 

1. Recessed conduit boxes

 

 

 

2. Surface mounting boxes

 

 

 

3. Directly on walls

 

 

 

4. Table mounting with stand provided

Press the button on the bottom of the thermostat.
The front housing will detach from the baseplate.
Insert the batteries (provided) into the thermostat.
Mount the unit as described in section 3.
Offer the baseplate up to the thermostat. Snap it into position to close.

Press the On/Off button to turn the zone paired with the thermostat on 
or off.
The paired zone of the programmer must be in the following states for 
this function to operate:
In permanently ON mode
In Allday mode and zone in ON
In Auto mode and zone is ON
If the zone is timed off or in permanently OFF mode the On/Off button on 
the thermostat will not operate

Press the         button on the bottom of the thermostat, the front housing 
will detach from the baseplate.
Insert the batteries into the thermostat. 
Press the reset button on the PCB, ‘NO’ will flash on the screen.
Rotate the hand wheel clockwise until ‘YES’ appears on the screen.
Press the hand wheel once to confirm the setting.
The thermostat has now been reset and the current temperature will 
appear on the screen.

Heating ON symbol

Room temperature

Battery low symbol

Set point handwheel

Wireless symbol

Code button

Reset button

On / Off button

20221108_RFRB_OpIns_PK

EPH Controls Ireland

[email protected]    www.ephcontrols.com

EPH Controls UK

[email protected]    www.ephcontrols.co.uk

Reviews: