CJ-125 Operating and Maintenance Manual
8
Technical Data
SPECIFICATIONS
CJ-125
Motor Power
0.2 HP
Input Power
15 amps, 12V, DC rechargeable VRLA battery
Recharge Power
Standard: 0.3 amps, 115/230 V, 50/60 Hz AC
Water Requirements
On-Board
Output Water Pressure
125 PSI
Output Water Flow
0.7 GPM
Pump
Positive displacement diaphragm
Water Tank
3.3 gallons
Soap Tank
1.75 quarts
Noise Level
66 dBA
Dimensions
19” high x 18” wide x 10” deep
Weight
22 lbs net dry; 52 lbs at 3.3 gallons water and 1.75
quarts chemical
PROBLEM
PROBABLE CAUSE
REMEDY
Inconsistent and/or
erratic pressure
• Nozzle worn
• Nozzle clogged
• Water/chemical is low
• Air sucked into system
• Air in pump (not properly primed)
• Vacuum lock (cap vent clogged)
• Water temp too high
• Low battery
• Replace nozzle
• Clean nozzle orifice
• Add water and/or chemical
• Fill tank(s)
• Remove nozzle, prime pump
• Clean cap air vent
• Add cold water to
reduce temp
• Charge or replace battery
Motor continues to run
even though trigger is
released
• High pressure system or pump
hydraulic circuit not watertight
• Air in system
• Tank(s) empty
• Check for leaks at spray gun
and pump
• Re-prime the unit
• Fill tank(s
)
Motor stops
abruptly
• Battery too low to operate
• Battery wire(s) not connected
• Power switch off
• Thermal breaker tripped
• Charge or replace battery
• Check battery wires
• Turn switch on
• Turn off, let unit cool
Motor buzzes but fails
to start or does not start
at all
• Problems with pump auto shut-off
• Unit in disuse for extended time
• Pressure needs to be relieved
• Contact factory
• Contact factory
• Squeeze trigger and relieve
pressure
No water flow/Water
not priming
• Clogged check valve
• Clean out/replace the
check valve
Troubleshooting
CJ-125
CJ-125