background image

©2018 All Rights Reserved. 

3

15A, Type F

GUIDE TO GRAPHICAL SYMBOLS

Fuse; replace only 
with fuse of the 
same type and 
rating. (This is a 
12V battery circuit 
using a Type F 
fused rated 250V)

Read all
instructions

Eye protection
required

Direct
Current (DC)

Charging
Connector
Polarity

High Pressure 
Output. 
Direct spray 
away from 
persons, pets, 
equipment, 
and electrical 
outlets.

Read and understand all instructions before using the unit. Failure to follow all instructions listed 
below may result in electric shock, fire and/or serious personal injury.

Save these Instructions!!

•  Always check the unit, hoses, fittings, etc. before each use.
•  Do not fill with gasoline or any other flammable liquid. Do not operate in explosive  

atmospheres, such as in the presence of flammable liquids, gases or dust.

•  Make sure there is adequate ventilation in the work area.
•  Stay alert, watch what you are doing and use common sense when operating this unit.
•  Keep bystanders, children, and visitors away while operating this unit.
•  Turn unit off and relieve pressure in the hose when done.
•  Do not use while tired or under the influence of drugs, alcohol, or medication.
•  Use only the supplied battery charger. Do not handle the charger with wet hands.
•  Do not use the unit while plugged into the battery charger.
•  Be careful – a fully filled unit is heavy!! Do not make any sudden movements when using 

this unit with the shoulder strap.

•  Do not overreach or stand on unstable support. Keep proper footing and balance at all 

times.

•  Wear rubber gloves, rubber boots, goggles or face-shield, etc. Detergents and 

chemicals may cause injuries to the eyes and skin. Protect yourself from direct skin 
contact with the chemicals and debris found in the coil cleaning environment.

• 

Do not use any acid or cleaners that contain sodium or potassium hydroxide!!

  

Call 

SpeedClean

 to check compatibility before using any chemical in the CoilJet

®

.

• 

Do not mix chemicals!!

 Mixing incompatible chemicals may cause damage to the unit 

or cause dangerous, life-threatening chemical reactions.

•  Do not use the unit if it does not operate properly or has been damaged. Do not try to 

service the unit yourself - call 

SpeedClean

 for assistance. Service must be performed only 

by qualified repair personnel.  Service performed by unqualified personnel could result in 
a risk of injury and voids the warranty.

•  Never point the spray gun at anyone. Do not direct stream at eyes or mouth.
•  Always turn machine off after use or when tank is empty. Running a water pump “dry” 

drains the battery and may cause damage.

•  Do not spray the unit with water or chemicals.
•  Do not allow the unit to freeze or leave in freezing temperatures.
•  Do not use water with a temperature of more than 140°F (60°C).
•  Use only approved accessories and replacement parts.
•  Follow maintenance procedures outlined in this manual.

Important Safety Instructions

CJ-125

Содержание CoilJet CJ-125

Страница 1: ...SpeedClean Innovative Maintenance Tools OPERATING MAINTENANCE INSTRUCTIONS U S Patent 9 381 549 MODEL CJ 125 CoilJet Portable HVAC Coil Cleaning System ...

Страница 2: ...ting 8 Declaration of Conformity 9 Español 10 17 CJ 125 This unit has been carefully tested and inspected at the factory and is warranted to be free from defects in material or workmanship The company will under this warranty repair or replace any parts which prove upon examination to be defective This warranty is valid for one year from date of purchase from an approved vendor For a list of appro...

Страница 3: ...t make any sudden movements when using this unit with the shoulder strap Do not overreach or stand on unstable support Keep proper footing and balance at all times Wear rubber gloves rubber boots goggles or face shield etc Detergents and chemicals may cause injuries to the eyes and skin Protect yourself from direct skin contact with the chemicals and debris found in the coil cleaning environment D...

Страница 4: ... fully assembled However the battery leads need to be connected before first use Open the battery door remove the battery and connect the leads red wire to the positive terminal and black wire to the negative terminal NOTE The battery should be fully charged before first use When you first unpack the unit and connect the battery plug the charger into a 120V AC outlet and charge the unit until the ...

Страница 5: ... Reserved 5 1 CJ125 KIT SB Battery and Charger Kit 2 8944 12V Vehicle Adapter for Battery Charger Common Optional Accessories CJ 125 1 2 90º SPRAY WANDS 8945 24 24 8945 36 8945 48 48 8945 60 60 8945 FLEX 24 Flexible 24 ...

Страница 6: ...ction wires to the fresh battery Caution black battery connection wire to the negative black battery terminal and red wire to positive red battery terminal e Replace the battery in the battery compartment and replace the battery cover Normal Coil Cleaning Operation 1 Fill the water and chemical tanks Before priming the pump make sure chemical valve is fully closed and remove any nozzle from the sp...

Страница 7: ...tored above freezing temperatures for short periods of time less than 1 week with liquid in the tanks 4 To protect the unit from damage chemical and water should be drained from the tanks and the pump and chemical valve flushed with clean water before the unit is placed in long term storage 5 If the unit is to be stored for an extended period of time in an unheated location pour about 1 quart of R...

Страница 8: ...attery Replace nozzle Clean nozzle orifice Add water and or chemical Fill tank s Remove nozzle prime pump Clean cap air vent Add cold water to reduce temp Charge or replace battery Motor continues to run even though trigger is released High pressure system or pump hydraulic circuit not watertight Air in system Tank s empty Check for leaks at spray gun and pump Re prime the unit Fill tank s Motor s...

Страница 9: ... 2018 All Rights Reserved 9 Declaration of Conformity CJ 125 ...

Страница 10: ...á la validez durante un año a partir de la fecha de adquisición por parte de los proveedores aprobados Para obtener una lista de proveedores aprobados viste nuestra pagina en el internet o contáctenos Esta garantía no cubre desgastes inusuales usos indebidos ni daños derivados de accidentes o utilizaciones del dispositivo que en modo alguno se encuentren fuera del uso razonable incluida la aplicac...

Страница 11: ...cho gafas protectoras o máscara etc Es posible que los detergentes u otros productos químicos ocasionen lesiones a los ojos y la piel Evite el contacto directo de la piel con las sustancias químicas y desechos que se encuentren en el entorno de funcionamiento del dispositivo No utilice ningún producto de limpieza que contenga hidróxido sódico o hidróxido potásico Comuníquese con SpeedClean para co...

Страница 12: ...A Type F GUÍA DE SÍMBOLOS GRÁFICOS Fusible reemplace sólo un fusible del mismo tipo y valor Este es un circuito de batería de 12 V con una F fusible Tipo nominal 250V Lea todas las instruc ciones Protección de los ojos requiere Corriente Directa DC Polaridad del conector de carga Salida de alta presión Dirigir aerosol lejos de personas equi pos domésticos y los enchufes eléctricos CJ 125 1 9647 1 ...

Страница 13: ... batería Comunes los Accesorios Opcionales No se muestran CJ2 24 Cargador de batería CJ2 06 S Conjunto de bomba de motor CJ2 07 Válvula pequeña de verificación CJ2 07 1 Válvula grande CJ2 17 Fusible de 15 amperios 8 9 1 2 10 11 12 90º LANZA ROCIADORA 8945 24 24 8945 36 8945 48 48 8945 60 60 8945 FLEX 24 Flexible 24 ...

Страница 14: ... interruptor de energía está en la posición de apagado OFF durante el proceso de carga 4 El piloto naranja o rojo indica que la batería se está cargando El piloto verde luminaro indica que la batería está completamente cargada 5 El dispositivo puede mantenerse conectado indefinidamente una vez que la batería se haya cargado por completo el cargador adoptará el modo de mantenimiento de carga Cambia...

Страница 15: ...l químico para que esta penetre y actué efectivamente sobre los serpentines 10 Enjuáguelos con agua limpia 11 Coloque el interruptor en la posición de apagado OFF Libere siempre la presión apretando el gatillo con la pistola apuntada en una dirección que no entrañe riesgos Nota Puede haber un retraso de diez segundos para que el producto químico sea removido de la manguera Proporciones de dilución...

Страница 16: ...o para un periodo de tiempo prolongado 5 Si guarda el dispositivo para un periodo prolongado en un lugar sin calefacción suministre en el tanque aproximadamente 1 litro de anticongelante de caravana Abra la válvula de químicos y ponga la bomba en funcionamiento hasta que la pistola expulse anticongelante Apague el dispositivo y libere la presión IMPORTANTE utilice solamente anticongelante para car...

Страница 17: ...ma de alta presión no impermeable Aire en el sistema Tanque s vacío s Buscar fugas en pistola y bomba Volver a cebar el dispositivo Rellenar tanque s El motor se detiene bruscamente Batería demasiado baja para su funcio namiento Cable s de batería no conectado s Interruptor en OFF Interruptor térmico desconectado Cargar o reemplazar batería Inspeccionar cable Cambiar a ON Apagar y dejar enfriar El...

Страница 18: ...of Crossford International SpeedClean reserves the right to improve products contact the factory for the latest configuration and uses PO Box 110301 Stamford CT 06911 0301 888 700 3540 www speedclean com SpeedyFoam CoilJet Condenser Needle Mini Split Bib Kit ...

Отзывы: