6. Turn water on and check for leaks.
7. If leaks are found, retighten the hose couplings.
8. Continue tightening and rechecking until no leaks are found.
FLW2445N_SVG1
COLD
HOT
1
2
3
4
5
6
7
8
1.
Filter Screen (Screen must be facing outward)
2.
Fill Hose
3.
Plain Rubber Washer
4.
Cold Water Connection
5.
Hot Water Connection
6.
Install this end of hose to valve connections at rear of
washer
7.
Install this end of hose to water supply faucet (Black col-
ored or hex nut shaped coupling for BSPP thread)
NOTE: Both couplings on fill hoses included with
models starting Serial Nos. beginning 1810 are
BSPP thread.
8.
Faucet
Figure 7
IMPORTANT:
Hoses and other rubber parts deteriorate after exten-
ded use. Hoses may develop cracks, blisters or materi-
al wear from the temperature and constant high pres-
sure they are subjected to.
All hoses should be checked on a monthly basis for
any visible signs of deterioration. Any hose showing
the signs of deterioration listed above should be re-
placed immediately. All hoses should be replaced ev-
ery five years.
IMPORTANT: Turn off water supply faucets after check-
out and demonstration. Owner should turn off water
supply whenever there will be an extended period of
non-use.
Install Washer Electrical Cord
400 Volt, 50 Hertz, 9.8 Amp
NOTE: Refer to 7-14-190 conversion instructions for
400 Volt, 3-Phase WYE, 4 wire plus earth, 9.8 Amp to
230 Volt, 3-Phase DELTA, 3 wire plus earth conversion
instructions. Refer to Kit 805832 for converting to 230
Volt, Single-Phase, 2 wire plus earth, 21 Amp connec-
tion.
Have a qualified electrician install appropriate electrical recepta-
cle.
To attach electrical cord supplied with machine (400 Volt WYE):
1. Remove electrical access panel on rear of machine.
2. Remove plastic plug from hole in rear of machine.
3. Install strain relief, supplied with machine, in hole.
4. Put power cord through hole.
FLW2337N_SVG1
1
1.
Install power cord through this hole after removing plastic
plug. Use strain relief supplied in accessories bag.
Figure 8
5. Attach power cord wires as shown in
6. Tighten down the strain relief (supplied with unit) on the
power cord.
7. Reinstall access panel.
Installation
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
14
Part No. 805197ENR6
Содержание SF3JM