background image

(alternating current) circuit protected by a 15 Ampere fuse,
equivalent fusetron or circuit breaker.

The three-prong earth/ground plug on the power cord should be
plugged directly into a polarized three-slot effective earth/ground
receptacle rated 120 Volts AC (alternating current) 15 Amps. Re-
fer to 

Figure 26 

to determine correct polarity of the wall recepta-

cle.

Plug Cord Into Separately Fused 15 Amp Circuit

DRY2022N_SVG

7

6

8

5

4

3

2

1

1.  

L1

2.  

Earth/Ground

3.  

Neutral

4.  

Round Earth/Ground Plug

5.  

Neutral Side

6.  

0 V.A.C.

7.  

120 ± 12 V.A.C.

8.  

120 ± 12 V.A.C.

Figure 26

 Earth/Ground Information

This appliance must be properly connected to protective earth/
ground. In the event of malfunction or breakdown, the earth/
ground will reduce the risk of electric shock by providing a path
of least resistance for electric current.

The dryer is equipped with a cord having an equipment earth/
ground conductor and a three-prong earth/ground plug. The
three-prong earth/ground plug on the power cord should be plug-
ged directly into a polarized three-slot effective earth/ground re-
ceptacle rated 110/120 Volts AC (alternating current) 15 Amps.

WARNING

This unit is equipped with a three-prong (earth/
ground) plug for your protection against shock haz-
ard and should be plugged directly into a protective
earth/ ground three-prong receptacle. Do not cut or
remove the earth/ground prong from this plug.

W823

WARNING

Improper connection of the equipment earth/ground
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the dryer is properly
connected to a protective earth/ground.

W886

Do not modify the plug provided with the dryer – if it will not fit
the outlet, have a proper outlet installed by a qualified electrician.

NOTE: Have a qualified electrician check the polarity of
the wall receptacle. If a voltage reading is measured
other than that illustrated, the qualified electrician
should correct the problem.

Do not operate other appliances on the same circuit.

WARNING

To reduce the risk of an electric shock or fire, DO
NOT use an extension cord or an adapter to connect
the dryer to the electrical power source.

W037

 Recheck Steps

Refer to Installer Checklist on the back cover of this manual and
make sure that dryer is installed correctly.

 Check Heat Source

 Electric Dryers

1.  

Close the loading door and start the dryer in a heat setting (re-
fer to the operation instructions).

2.  

After the dryer has operated for three minutes, the exhaust air
or exhaust pipe should be warm.

 Gas Dryers

Installation

  Part No. 514319R1

©

 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT

  21

www.goedekers.com

Содержание ADEE8RGS

Страница 1: ...tions for Dryers Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www speedqueen com Part No 514319R1 October 201...

Страница 2: ...www goedekers com...

Страница 3: ...e in your building Clear the room building or area of all occu pants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas sup...

Страница 4: ...reduce the risk of severe injury or death follow all installation instructions Save these instructions W894 WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids i...

Страница 5: ...re Plug 15 Connecting Power Cord with Four Wire Plug 17 Reverse Door if Desired 18 Wipe Out Inside of Dryer 20 Plug In the Dryer 20 Electric Dryer 20 Gas Dryer 20 Recheck Steps 21 Check Heat Source 21...

Страница 6: ...in 391 mm F 15 44 in 392 mm G 26 875 in 683 mm H 4 in 102 mm I 0 4 in 10 mm J 28 in 711 mm K 4 5 in 114 mm L 8 in 203 mm M 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm metal ducting With le...

Страница 7: ...91 mm F 15 44 in 392 mm G 2 8 in 70 mm H 2 3 in 60 mm I 26 875 in 683 mm J 4 in 102 mm K 0 4 in 10 mm L 28 in 711 mm M 4 5 in 114 mm N 8 in 203 mm O 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102...

Страница 8: ...e of the dryer 7 Plug in the dryer 8 Recheck steps 9 Start and run the dryer in a heat setting to verify dryer is heat ing Position and Level the Dryer 1 Install dryer before washer This allows room f...

Страница 9: ...DRY2662N_SVG 3 1 2 1 Dryer Base 2 Level 3 Leveling Leg Figure 2 Installation Part No 514319R1 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 9 www goedekers com...

Страница 10: ...2664N_SVG 1 C A D E H 3 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 3 Installation 10 Copyright Alliance Lau...

Страница 11: ...y connection 6 inches 152 mm is recommended when venting through rear of unit Table 1 IMPORTANT In mobile home installations gas dryers MUST be permanently attached to the floor at the time of install...

Страница 12: ...ructure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of dryer DO NOT install fle...

Страница 13: ...1 4 in 102 mm D802I_SVG 1 1 2 5 in 64 mm Maximum length of 4 in 102 mm diameter rigid metal duct 0 65 feet 19 8 m 55 feet 16 8 m 1 55 feet 16 8 m 47 feet 14 3 m 2 47 feet 14 3 m 41 feet 12 5 m 3 36 f...

Страница 14: ...t 915 m the nat ural gas valve spud orifice size must be reduced to ensure com plete combustion Refer to Table 3 Natural Gas Altitude Adjustments Altitude Orifice Size Part No feet m No inches mm 3000...

Страница 15: ...function or breakdown the earth ground will reduce the risk of electric shock by providing a path of least resistance for electric current The cord kit must be equipped with a cord having an equipment...

Страница 16: ...2 13 10 11 7 6 1 14 1 A typical 30 Amp Three Wire Receptacle NEMA Type 10 30R 2 120 12 V A C 3 240 12 V A C 4 Intermediate Fuse Box may be omitted if service entrance box is fused 5 Wall Receptacle 6...

Страница 17: ...of the earth ground connection before plugging the cord into an outlet Use an acceptable indicating device connected to the center earth ground pin of the plug and the green screw on the back of the c...

Страница 18: ...inal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach along w...

Страница 19: ...RY1916N_SVG B A Figure 17 4 Rotate door panel 180 degrees as shown D273P_SVG Figure 18 5 Remove door strike from door liner and reinstall on opposite side DRY1917N_SVG Figure 19 6 Insert liner under f...

Страница 20: ...d with a 3 prong earth ground plug Refer to serial plate for specific electrical requirements NOTE The wiring diagram is located in the control hood WARNING To reduce the risk of fire electric shock s...

Страница 21: ...d and should be plugged directly into a protective earth ground three prong receptacle Do not cut or remove the earth ground prong from this plug W823 WARNING Improper connection of the equipment eart...

Страница 22: ...lazy yellow tipped flame indicates lack of air A harsh roar ing very blue flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to t...

Страница 23: ...www goedekers com...

Страница 24: ...AS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D233I_SVG1 7 Plug In the Dryer Electric D275I_SVG1 Gas D254I_SVG CHECK CHECK 4 ELECTRIC ONLY Connect Electrical Cord D679I_SVG1 8 Recheck Steps CHE...

Отзывы: