9
Upgrading older weather stations
Older WatchDog mini-stations can be upgraded with a
new micro-controller chip (3300WD2). Full weather sta-
tions can be upgraded with a replacement micro-controller
with integrated clock board (item 3300CBWM). Micro
stations can be upgraded through SpecWare software.
Contact Spectrum Technologies for details.
Original WatchDog weather stations (models 525, 550,
600, 700, and 900), 200- and 400- series purple loggers,
and A-series loggers are incompatible with the SMEC
300.
The EC sensor can be calibrated with the Soil Sensor
Reader or with the EC Calibration Device (item
6470CAL). The calibration procedures are included in the
product manuals for each device. With both devices, cali-
bration is done with a 1.41 mS/cm calibration standard.
Some important points to remember when calibrating the
EC sensor:
1. Be careful not to touch the carbon
ink electrodes. Oils from your fingers
can affect the accuracy of the sensor.
Before calibrating, the electrodes
should be cleaned well with alcohol.
2. Immerse the sensor up to the immer-
sion indicator on the sensor molding
(indicated by arrow in image to right).
3. Wait until the sensor has come to
thermal equilibrium before initiating
the calibration routine.
Calibrating the
EC Sensor