14
In some instances, greater accuracy is desired than can be
obtained from a general soil moisture calibration equation.
In this case, it is necessary to perform a calibration on
your unique soil. Essentially, a relation needs to be devel-
oped that relates the meter’s electronic reading to the ac-
tual volumetric water content (VWC). This will require
that some other method be used to measure the VWC.
Mineral Soils
VWC data can be measured in a lab setting by measuring
the weight of a perforated soil column of known volume
that is saturated, drained and dried. This method is pre-
ferred because the soil structure is not altered during the
testing procedure. This procedure requires a weighing
scale, a soil container with a height slightly greater than
the SMEC 300 sensor (2.8 inches) and, depending on the
ambient drying conditions, can take several weeks to com-
plete. The procedure is briefly outlined below. Readings
of the soil moisture circuit can be taken either with the
Soil Sensor Reader or a WatchDog weather station. In
either case, the device should be set to Raw AD mode.
For the weather stations, when channel A is configured to
read
Raw Sensor (raw)
, it will read the soil moisture cir-
cuit only. Nothing will be read on channels B or C.
1. Build a small container to hold the soil from a non-
metallic material such as PVC. The sensitive volume of
the sensor is not large so the container diameter does not
have to be very big. In fact, soil-moisture gradients will
form in the container as it dries so, unless several sensors
will be used in the calibration, a small container will pro-
vide the best results. Cap the bottom of the container and
drill holes in the cap and in the container’s sides. This will
allow water to permeate and drain as well as facilitate dry-
soil moisture
Calibrations
Содержание WaterScout SMEC 300
Страница 1: ...SMEC 300 Soil Moisture Sensor PRODUCT MANUAL Item 6470 6 6470 20 ...
Страница 2: ...2 ...
Страница 21: ...21 Figure 1 ...