13
Horizontal Orientation
Digging a small hole or trench
in the soil allows the sensors to
be installed horizontally. The
sensors are pushed directly into
the exposed face of undis-
turbed soil. Because the sensor
board is flexible, care should
be taken to avoid snapping it
during installation. To limit the effect of water moving
vertically through the soil profile, the sensors should be
installed so the flat face is perpendicular to the soil sur-
face. For the same reason, if sensors are installed at multi-
ple depths, they should be offset from one another.
Removal
Care should be taken when removing a sensor that is
firmly embedded in soil. Pull on the molding only. Pull-
ing on the cable risks damaging the wiring.
Suggestions for protecting sensor cables from rodent
s
- For vertical installations, run sensor cables through PVC
pipe. This can be the same tube used as an installation
tool.
- For sensor cable that will be running parallel to the
ground, either above or below the soil surface, the sensor
cable can be fed through flexible conduit or drip irrigation
tubing. When using drip irrigation tubing, it is preferable
to use used tubing. This is because the tubing will have
the curl taken out of it and will be easier to keep straight.
A slit should be cut into the tubing with a box cutter and
the cable pushed inside. If the cable and protective cover
are not buried, they can be secured to the ground wire
with hooks or turf staples.