Description of the DESKLINE® DL5/DL6 system

Each DESKLINE®  DL5/DL6 lifting units is equipped  with a motor and parallel/memory  

drive is ensured by means of software in the CBD4/CBD5/CBD6 that also takes account 

of oblique load on the desk. Soft start and stop are also part of this software, which 

ensures a soft start and stop when adjusting the desk.

Application of the DESKLINE® DL5/DL6 system:

Irrespective of the load the 

duty cycle 10% ~ 6 min./ hour or max. 2 min. at 

continuous use

 stated in the data sheets, must 

NOT

 be exceeded as this will result 

in a superheating of the motor, the brake and the spindle nut. Exceeding the duty cycle 

will result in a dramatic reduction of the life of the system.
The DESKLINE®  DL5/DL6 system range contains the following products:

•  1 control box CBD4/CBD5/CBD6

•  1 single DL5/DL6 or 2, 3, or 4 parallel

•  1 exchangeable mains cable

•  1, 2, 3, or 4 motor cables

•  1 DP1U/DPF1M (if memory function is required)  DP1C/WDPL/DPT/DPF1C (if 

memory function and display is required) or 1 DPA/DPB/DP1K/DP1V/DPF1K (if only 

up/down is required.)

Anti-Collision™

The function (anti-collision)  is an option for the standard CBD4/CBD5/CBD6 advanced/

control box software 0077432 version 1.66 and later. A system with anti-collision can limit 

material damages on a desk if a collision with a solid object should occur

Method of operation

When the DL/DB’s are running the CBD4/CBD5/CBD6 monitors the current 

consumption on each channel using a special algorithm. If the current consumption 

on one channel is increased more than a predefi ned slope, a collision is assumed and 

all channels are stopped immediately and all DL/DB’s will start to run in the opposite 

direction (approx. 50 mm). This return drive is done automatically and continues with 

or without any control key pressed (for max. 2.5 sec.).
The anti-collision  sensitivity is different in upward and downward direction. Upwards 

the force is approx. 20 kg. Downwards the load will be approx. 40 kg + the load on the 

DL/DB (the desk + what is on top of the desk). The 40 kg are needed to activate the 

anti-collision function.

Situations where the anti-collision does not work

There are situations where the anti-collision will not be activated. These situations are:

•  If the collision happens during the initialisation phase

• 

If the collision happens within the fi rst 1000 msec or after the control button has 

been released

• 

If the collision happens between the fl oor and the table and the load on the desk + 

the weight of the legs are lower than 40 kg

•  If the collision happens over too long time, e.g. if the collision is with a soft object.

Misc. on the DESKLINE® DL5/DL6 system

This system is a DESKLINE system developed for desks and for indoor use in offi ces. Do not 

use it in industrial kitchens or in other enviroments that have to be cleaned with aggressive 

detergents.  Do not bolt the legs to the fl oor so that free movement is prevented. This could 

cause serious damage to the legs in fault situations.

Warranty

There is a 36 months’ warranty on the DESKLINE products against manufacturing faults 

from the production date of the individual products (see label).

LINAK A/S’ warranty is only valid in so far as the equipment has been used and main-

tained correctly and has not been tampered with. Furthermore, the system must not be 

exposed to violent treatment. In the event of this,

the warranty will be ineffective/invalid. For further details, please see LINAK A/S ordinary 

conditions of sale.

Maintenance

Clean dust and dirt on the outside of the system at appropriate intervals and inspect them 

for damage and breaks.  Inspect the connections, cables, and plugs and check for correct 

functioning as well as fi xing points.

Service of double-insulated products:
Class II

A Class II or 

double insulated

 electrical appliance is one which has been designed in 

such a way that it does not require a safety connection to electrical earth (US: ground).
The basic requirement is that no single failure can result in dangerous voltage becoming 

exposed so that it might cause an electric shock and that this is achieved without relying 

on an earthed metal casing. This is usually achieved at least in part by having two layers of 

insulating material surrounding live parts or by using reinforced insulation.

There is no earthing/grounding means provided on the product, and no earthing/ground-

ing means is to be added to the product.
In Europe, a double insulated appliance must be labelled “Class II”, “double insulated” or 

bear the double insulation symbol (a square inside another square).

Servicing a double-insulated product requires extreme care and knowledge of the system, 

and is to be done only by qualifi ed service personnel. Replacement parts for a double-in-

sulated product must be identical to the parts they replace.

The cleaners and disinfectants must not be highly alkaline or 

acidic (pH value 6-8).

Electrical connection of the DL5/DL6 system

The DESKLINE® DL5/DL6 system is to be connected as shown on fi gure 4. Each DL5/

DL6 is to be connected to the sockets on the control box by means of the motor cables, 

which have an 6-pin plug in each end.  Finally, the mains cable is to be mounted and 

power switched on.

Please note that the control box must only be connected to the voltage stated on the 

label.

CBD4/CBD5/CBD6 with earth

The CBD4/CBD5/CBD6 earth cable to be mounted on the desk construction (typically the top 

frame) in a way that ensures good electrical contact. The function of the earth cable is to earth 

the desk and ground static electricity. The earth connection does not protect other electrical 

products.

CBD4/CBD5 with mains cut-off (non ZERO models)

If the power cable is damaged it has to be replaced by an authorized LINAK 

service centre to avoid any danger.

DL5/DL6 cable

DL5/DL6

Hook for cable relief

Main 

cable

DL5/DL6

DP/WDPL

Содержание Honors Lectern 55178

Страница 1: ...o report information regarding missing parts or damage to purchase parts or acces sories or if you have any questions please contact us Thank you for purchasing Spectrum products Spectrum Industries I...

Страница 2: ...cords that are damaged Unplug power cord from electrical outlet by gripping the cord Do not unplug the power cord by pulling only on the cord Do not step on drive over drag or place objects on the po...

Страница 3: ...ience side to lock into place 1 With the side skirt and base holes aligned install a 1 4 20 x 1 1 2 PHM screw through the top of the base to secure each side skirt Figure 1C Starting the screw by hand...

Страница 4: ...terfere with objects or people Use caution when raising or lowering the worksurface Preparation Read all instructions before operation Make sure lectern power cord is plugged in Locate the Up and Down...

Страница 5: ...a keyboard tray or flipped and used as a drawer Quick release door The symmetrical door can easily be removed or switched to be hinged from left or right using the quick release hinge lever located o...

Страница 6: ...Compatible with most 4 75 cooling fans with 4 13 mounting hole spacing 12 mounting locations available Figure 5D 1 To remove the rack cube open or remove the door Figure 5A 2 Remove the upper and low...

Страница 7: ...n mounting location Fans should be mounted inside cube to provide clearance This will take approximately 3RU s of rack space Rack rail Rack rail Overall depth Note Check the dimensions of all equipmen...

Страница 8: ...Figure 6B To lower or flip up the shelf press and hold the shelf bracket levers while slowly lowering or raising the shelf Do not exceed a maximum of 50 lb of weight on the shelf Do not move the unit...

Страница 9: ...e making sure all devices fit within the maximum cutout space available in the overbridge panel See Figure 9B 9C See specifications for cutout clearances B Locate and mark the exact cutout area s on t...

Страница 10: ...ed by Spectrum to ensure clearance of brackets keyboard slides or other objects under the worksurface Contact Spectrum to specify cutout size s and location s Overbridge Section View C C Worksurface o...

Страница 11: ...Control button connection To wall outlet Control box Note Provide enough slack in the power cord to accommodate full lectern extension A separate power strip is recommended not included to plug the c...

Страница 12: ...ys classrooms or other areas where they will be walked on Do not leave unit unattended in areas where children have access Keep doors closed and locked whenever unit is unattended or parked Keep caste...

Страница 13: ...49 Attaches to audience side of lectern 22 75 W 57 79 cm x 10 8 H 27 4 cm To get panel customized contact Spectrum for details New logos require a first time logo charge Customer installed Shipping we...

Страница 14: ...essories and detailed warranty information Cutout required 5 25 W 13 3 cm x 2 D 5 1 cm mounts to surface thicknesses up to 1 5 Power cord 9 274 cm with 90 flat plug with 45 rotation Power receptacles...

Страница 15: ...instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product It i...

Страница 16: ...e cleaned with aggressive detergents Do not bolt the legs to the oor so that free movement is prevented This could cause serious damage to the legs in fault situations Warranty There is a 36 months wa...

Страница 17: ...y pressing the up button 2 Remove any items under the lectern worksurface 3 Reset the lift mechanism see below for procedure Misaligned actuators due to unbalanced loads Reset Procedure 1 Unplug then...

Страница 18: ...BY SPECTRUM FOR THE PRODUCT AT ISSUE AND RECALLACTION EXPENSES SPECTRUM SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARIS ING OUT OF BREACH OF CONTRACT WARRANTY TORT INCLUDING...

Отзывы: