System Information

System Specifications

• 

Ultra-high purity water (18 megohm-cm resistivity)

• 

Super-capacity, highest removal rates of phosphates, silica,  

 

nitrates, and heavy metals 

• 

Provides up to five times longer cartridge life

• 

Only DI System to remove non-reactive colloidal silica, 

 

which passes through RO membranes and ordinary DI 

 cartridges

• 

Exclusive 4-Stage Deionizing System eliminates contami- 

 

nant leakage with secondary back-up cartridges

• 

Electronic Purity Monitor for accurate mixed-bed

 

DI cartridge diagnostics 

• 

Clear filter housings 

• 

Filter wrench included

• 

Dimensions: 20” x 7” x 16”

System Description 

SpectraPure’s new Four-Stage Deionizing System, The Ultimate™ 
is optimized for use with RO water and provides the most com-
plete removal of silica, colloidal silica, phosphates, nitrates, and 
heavy metals available.

The Ultimate™ eliminates contaminant leakage from exhausted 
DI cartridges with the addition of secondary back-up cartridges. 
An exhausted deionization cartridge will leach the removed 
impurities back into the water at levels many times higher than 
originally found in the source water. The addition of the two 
secondary DI stages prevents this leakage. 
When the first SilicaFree Cartridge (DI-SFCC-10) changes color 
upon exhaustion, it is removed and the Stage 2 back-up cartridge 
is rotated to the first position and a new cartridge replaces the 
second-stage cartridge.

SpectraPure

®

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

11

System Troubleshooting Guide

Cause 

  Corrective 

Action

No color change in
Stage #1 or #2 

 

The tap water pH may be too high

Membrane Testing

Replacement Parts

Model  

Replacement Part

(2)  DI-SFCC-10  SilicaFree™ Color Change DI Cartridge
(2)  DI-AR-CI-10  Chloramine Removal Cartridge

(2) DI-MB-10 

Mixed-Bed Cartridge for Laboratory Use

XWR-UNIV Filter 

Wrench

Optional Accessories

Model  

Optional Part

See our Catalog or our Web Site for Liquid Level
Controls and other Optional Accessories

Содержание The Ultimate DI System

Страница 1: ...ro rated the performance of membrane elements for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters listed on page 3 of this manual Most municipal water supplies meet these requirements Terms and Conditions of Sale 1 To obtain service under this warranty the defective system or...

Страница 2: ...nates contaminant leakage from exhausted DI cartridges with the addition of secondary back up cartridges An exhausted deionization cartridge will leach the removed impurities back into the water at levels many times higher than originally found in the source water The addition of the two secondary DI stages prevents this leakage When the first SilicaFree Cartridge DI SFCC 10 changes color upon exh...

Страница 3: ... contaminated product water due to exhausted cartridges is completely eliminated With the majority of contaminants now removed by Stages 1 and 2 the water is then passed through two additional stages of DI resin Stages 3 and 4 have our Chloramine Removal Car tridges DI AR CI 10 They will provide longer life than standard mixed bed cartridges when used to treat water containing chlorine chloramine ...

Страница 4: ...tween GREEN and RED between successive depressions of the push to test water purity monitor A Do not press the push to test button rapidly in quick succes sion Wait at least 1 minute between two successive depressions of the button for an accurate reading Q How should the probe be mounted for an accurate reading A The probe should be mounted VERTICALLY at the bottom of the T Q How long does the ba...

Страница 5: ...Needed One DI AR CI 10 Deionizaton cartridge filter wrench Procedure 1 Remove the filter housing from Stage 3 by unscrewing it counter clockwise as viewed from the bottom 2 Remove and discard the old cartridge from the housing 3 Remove the housing and cartridge from Stage 4 and re install the cartridge in Stage 3 Make sure the cartridge is installed in the correct direction as marked on the filter...

Страница 6: ...rapure com Visit us on the web www spectrapure com 7 The Ultimate DI System has been engineered to provide fool proof operation and double assurance that contaminants will not be intro duced into the product water except in cases of extreme negligence The design theory to remember is that the cartridges will be replaced in a rotational pattern Stages 1 and 3 will always exhaust their capacity firs...

Отзывы: