background image

Ultra-High Efficiency RO/DI  

(MC-RODI-200UHE)

OWNER’S MANUAL 

INSTALLATION INSTRUCTIONS

WARNING

Please read carefully before proceeding with installation. Failure to follow any  

attached instructions or operating parameter may lead to the product’s failure and  

possible damage to property.

v2 2014-09-05

Содержание MC-RODI-200UHE

Страница 1: ...R S MANUAL INSTALLATION INSTRUCTIONS WARNING Please read carefully before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property v2 2014 09 05 ...

Страница 2: ... Getting to know your system 6 Setup Procedures 7 Installation of Floats and Bulkhead Fittings 7 Pressure Adjustment with Regulator 8 Reinstalling and Flushing DI Resin Cartridges 8 Connecting Bulkhead fittings 9 Final Connections 10 Maintenance Procedures Metering Diagnostics 11 Shelf Life of Filters 11 Sediment Prefilter Replacement 11 Carbon Block Prefilter Replacement 12 Reverse Osmosis Membra...

Страница 3: ...enoid Wht Wht Input Solenoid Flush Solenoid Connects to Pump Red Black RO Membranes Inside Housings OPERATIONAL SPECIFICATIONS NOTE MOST MUNICIPAL WATER SUPPLIES MEET THE ABOVE REQUIREMENTS IF WELL WATER IS USED PLEASE MAKE SURE THAT YOU OBTAIN A WATER TEST BEFORE INSTALLATION RO Feed water requirements Operating Pressure 40 80 psi 2 75 6 9 bar pH Range 3 11 Max Temperature 100 F 38 C Max Feed Tur...

Страница 4: ...ater temperature the ratio should be close to 1 1 As the water gets colder the ratio will increase by a small factor 4 The fourth and fifth stage filter are our MAXCAP DI cartridge followed by our SilicaBuster DI cartridge These two cartridges remove the remaining silicates phosphates and nitrates that get by the RO membrane High and Low Float Operation 1 Floats are to be mounted horizontal when d...

Страница 5: ... needs to hold at least 10 gallons ELEVATION FOR SYSTEM When mounting your UHE make sure it is elevated above your fresh water reservoir GRAVITY DRAIN WATER FROM ELEVATED TANK TO TRASH CAN FOR SALT MIXING OR TO SUMP USE DELIVERY PUMP TO DELIVER WATER WHERE NEEDED FOR SALT MIXING OR TO SUMP 2 TOOLS RECOMMENDED FOR INSTALLATION 3 INTRODUCTION TO PUSH FITTINGS Push fittings are similar to a Chinese f...

Страница 6: ...am DI removed There is a large ionic load present in a new MaxCap DI cartridge Failure to flush this cartridge will shorten the life of the downstream DI TOP VIEW One Membrane Shown for Clarity NOTE When mounting your UHE make sure it is elevated above your fresh water reservoir B W INPUT PRESSURE SWITCH 2 PINS B W R FLOATS 3 SOCKETS W R SPARE 2 SOCKETS W W 24 VAC INPUT 2 PINS W W INPUT SOLENOID 2...

Страница 7: ...and Low Floats onto a open container such as a RubberMaidTM trash can The floats can be mounted by drilling a 5 8 hole The High Float shuts down the system while the Low Float turns the system on B Connect the floats to the Y adapter C Attach the 3 pin connector on the float switches to the UHE CONTROL MODULE NOTE Floats are to be mounted horizontal when dry and float up when wet In most instances...

Страница 8: ...ING AND FLUSHING DI CARTRIDGES A Disconnect power to the system and turn off the water supply line B Unscrew the third clear housing and reinstall the MaxCap Cartridge NOTE At this time leave the fourth clear housing empty C Turn on water supply line and reconnect power to system Allow water to run through the MaxCap Cartridge and down the drain until the right hand meter SET TO IN reads 000 D The...

Страница 9: ...N PAGE 7 1 4 BULKHEAD FITTING Use a paddle bit and carefully drill a 5 8 hole for installation at the top of the reservoir above the high level float 3 8 BULKHEAD FITTING Use a paddle bit and carefully drill a 13 16 hole for installation at the bottom of the reservoir below the low level float continuedonnextpage Left Hand METER 1 IN Tap Water OUT RO Water Right Hand METER 2 IN MaxCap Water OUT Si...

Страница 10: ...below the low level float STEP 10 FINAL CONNECTION A Direct the waste line yellow to a drain or connect it permanently to a drain pipe via a Drain Saddle Drain Saddle is not included with system B Inspect for leaks and do not leave the system alone until you are sure there are no leaks Monitor the system for 72 hrs SETUP PROCEDURES continued CAUTION An extremely long drain line may create a siphon...

Страница 11: ...u can store it in the refrigerator for up to 1 year Keep in its sealed original packaging You should always see moisture inside the bag If the membrane dries out it will not produce water and any warranty will be voided DEIONIZING CARTRIDGES DI Replacement DI cartridges are shipped in a Mylar Bag Keep them in their sealed original packaging until use You can store them for up to 1 year SEDIMENT PR...

Страница 12: ...ue may then be used to determine the condition of the membrane In this way the operator will know when the membrane needs to be replaced Membrane failure will be indicated by a reduction in the percentage rejection which will be determined by calculating the differential between the input and output TDS readings In order to accurately determine the condition of the RO Membrane a conductivity teste...

Страница 13: ...r 240 GPD TEMPERATURE COMPENSATION The viscosity of water changes with temperature Colder water does not pass through the membrane as easily as warm water Look up the water temperature on the chart below to determine the Temperature Compensation Factor TCF value Multipy it by the pressure compensated flow rate of 240 GPD For Example if your tap water temperature is 59 F The TCF is 0 730 Multiplyin...

Страница 14: ...mbrane housing When the membrane is aligned with the hole firmly push the membrane into the hole until it bottoms out 8 Place the black housing O ring on the housing rim and carefully screw the lid back on to the base 9 Reconnect the black tubing to the membrane feed push fitting TIPS FOR LONG MEMBRANE LIFE 1 Replacement of 0 2 micron ZetaZorb sediment filter once every 6 months This will prevent ...

Страница 15: ...sing by rotating it clockwise and hand tighten 5 Turn the supply line back on plug the power back in and redirect the product water to drain Allow water to run through the MaxCap DI Cartridge until the reading on the right hand meter set to IN is 000 6 Check system for leaks NOTE When replacing DI cartridges ALWAYS flush the MaxCap DI with the downstream cartridge removed Maintenance for SilicaBus...

Страница 16: ... Both floats need to be dry and level not drooping Extremely high production rate a Ruptured membrane i Replace it Milky colored water a Air in system i Air in the system is a normal occurrence with initial startup of the RO DI system This milky appearance will disappear during normal use within 1 2 weeks If condition recurs after filter changes drain tank 1 or 2 times The water in the Pure Water ...

Страница 17: ...r conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period credit the prorated amount of the current catalog price of the element The disposable filters and cartridges are not covered under the warranty To obtain service under this warrant...

Страница 18: ...ent Filter 0 2 Micron Sediment Filter 1st Stage Failure to use a ZetaZorb sediment filter for replacement will void the system s warranty CF 0 5 10 Carbon Filter 0 5 Micron Carbon Prefilter 2nd Stage MEM SP 0090 RO Membrane 99 Rejection SpectraSelectPlus Membrane 3rd Stage DI MC 10 MaxCap DI MaxCap Deionization Cartridge 4th Stage DI SB 10 SilicaBuster DI SilicaBuster Deionization Cartridge 5th St...