1.
Scroll down to
Dump Config to PCS.CFG
and press Enter. The system
will copy the configuration to a file called PCS.CFG, and save it in
your working directory. If a PCS.CFG file already exists, the
system prompts to see if you want to overwrite it.
2.
Copy the file to a diskette for safekeeping.
Swap controller cards
This procedure replaces the existing CSC controller cards with CSO
controller cards to support OAI.
1.
Power down the system.
2.
Disconnect and remove the existing CSC system and cabinet
controller cards.
3.
Install and connect the CSO system controller card.
4.
Install and connect the CSO cabinet controller cards.
5.
Power up the system.
Restore system configuration
1.
On the Operator’s Console, go to the directory where the
PCS.CFG file was dumped (your working directory).
2.
From the
Supervisor State Display
screen (F1) press Enter to display
the menu.
3.
Scroll down to
Restore Config
from
PCS.CFG
and press Enter. The
system will copy the configuration from PCS.CFG in your
working directory to the System Controller.
Continue with the remaining steps to complete the OAI installation.
Verify System and Cabinet Controllers
Support OAI
To support OAI, your system must have a System Controller and
Cabinet Controllers with a CSO prefix. Check the labels on the
controllers to be sure they support OAI.
On the Operator’s Console, verify that the
Supervisor State Display
(F1)
details screen for the Cabinet Controller and the System Controller
shows OAI as
Enabled
.