CoD Feature for the Spectra 2000 Library
Upgrade Library Capacity via Serial Port Interface
Connect to the serial port using the following procedure:
1.
Connect a serial cable to the library (the diagnostic port located by the serial
number tag).
2.
Use a serial port terminal emulation application (such as HyperTerminal) running
on a host computer.
The serial port settings are as follows:
Bits per second (BAUD):
115200
- In the event that your library does
not
have a
115.2K BAUD
label located
beneath the diagnostic serial port, set the bits per second to
9600
.
Data bits:
8
Parity:
None
Stop bits:
1
Flow control:
None
3.
Press the Enter key.
If you see the
FCCS>
prompt, enter
usermenu
.
4.
Once you see the TAOS Configuration Menu (Figure 11), go to Step 5.
TAOS CONFIGURATION MENU
=============================
Firefrog
Hardware 0
Boot code 2.1.0.0
Appl code 4.1.19.0 Jan 22 2002 17:13:45
=============================
[ 1 ] Password configuration
[ 2 ] Fibre configuration
[ 3 ] Ethernet configuration
[ 4 ] TAOS ITP configuration
[ 5 ] TAOS NDMP configuration
[ 6 ] Enable Device options
[ 7 ] Enable options
[ 8 ] Save changes
[ 9 ] Discard changes
[ a ] Reboot
[ ? ] Display help for this menu
[ESC] Exit from menus
Select an item: 7
Figure 11
The TAOS Configuration Menu.