![SPECS CCX 70 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/specs/ccx-70/ccx-70_user-manual_1343044010.webp)
CCX 70
V1.1 | 29 April 2016
Internal water detector
—stops operation in the event of a water leak inside the CCX
70.
Front panel maintenance cover
—this needs to be closed correctly before operation
can occur.
The UXC 1000 can also be connected to an interlock sensor, e.g. a pressure measurement
gauge. If this interlock is not in use, it needs to be bridged with a terminator (supplied).
If the XR 50 is correctly connected and the conditions described in this chapter are met, these
interlocks are safe and the XR 50 can be operated.
Caution!
Do not attempt to defeat the interlocks. Death, serious injury or severe dam-
age to the source can result if the interlocks are overridden.
2.3
Water Cooling
The XR 50 has the following requirements for the cooling water:
Flow rate: >2.5 l/min
Temperature: 20 ºC
There are a number of other important additional considerations for cooling water. These guar-
antee a long lifetime of the source as well as describing possible problems that might appear
during operation. Please read the chapter "Water Supply" on page 11 for a complete descrip-
tion of the water requirements.
Caution!
If several items of equipment share the cooling water supply (pumps, etc.),
make sure that the pressure and temperature is adequate and fulfills the
cooling requirements
for all instruments
.
The cooling requirements vary according to the source. The XR 50 and XR 50 M have two cool-
ing circuits:
Anode. This circuit is made when you fit the protection cap over the source.
Head. The connectors are on the body of the source, near the system flange.
The XR-MF only has a cooling circuit for the anode. Nevertheless, you should read the section
"Head Cooling Circuit" on page 8 as it contains useful information about connecting a closed-cir-
cuit chiller. Please also see the XR-MF manual for more details.
6
Содержание CCX 70
Страница 1: ...CCX 70 Cooling Water Controller User Manual V1 1 29 April 2016...
Страница 4: ...CCX 70 V1 1 29 April 2016 7 4 Interior Details 32 7 5 Specifications 33 Index 35 iv...
Страница 8: ...CCX 70 V1 1 29 April 2016 This page intentionally left blank 4...
Страница 13: ...9 CCX 70 V1 1 29 April 2016 Figure 1 Connection scheme for water cooling...
Страница 14: ...CCX 70 V1 1 29 April 2016 This page intentionally left blank 10...
Страница 22: ...CCX 70 V1 1 29 April 2016 This page intentionally left blank 18...
Страница 26: ...CCX 70 V1 1 29 April 2016 This page intentionally left blank 22...
Страница 32: ...CCX 70 V1 1 29 April 2016 This page intentionally left blank 28...
Страница 38: ...CCX 70 V1 1 29 April 2016 This page intentionally left blank 34...
Страница 40: ...This page intentionally left blank CCX 70 V1 1 29 April 2016 36...