![Speck pumps BADUSTREAM II Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/speck-pumps/badustream-ii/badustream-ii_owners-manual_1341840009.webp)
7. Installation of the Pump and the Control Box
!
CAUTION
!
WARNING
9
Fig. 9
B
ADU
S
TREAM
II
triple housing installation
: Before installing the Speck Pump, read
the entire pump owner's manual found in the pump
box.
Consult local codes for minimum distance between
pump and pool. Locate pump as close to the pool as
practical.
The air button works up to 50 ft. There is 50 ft. of air
tubing in
B
ADU
S
TREAM
II
box.
: To reduce the risk of injury, do not permit
children to use this product unless they are closely
supervised at all times.
The wiring of the pool motor and control box should
be done by a licensed electrician in accordance with
local codes. Be certain that the motor frame and
control box are grounded. Motor name plate has
voltage, phase, amp draw, and other motor
information as well as wiring connection instructions.
BONDING:
As required by National Electrical Code
Article 680-22, the pump motor must be electrically
bonded to the pool structure (reinforced bars, etc.) by
a solid copper conductor not smaller than No. 8 AWG
via the external copper bonding lug on the pump
motor.
GROUNDING:
Permanently ground the pump motor
and control box using a conductor of appropriate size.
Connect to the No. 10 green headed ground screw
provided inside the motor terminal box.
NOTE:
Do not connect to electric power supply until
unit is permanently grounded.
Section 6 concerns the electric motor and control box
only since all other parts, the pump, the jet unit, etc.
have complete and absolute separation from the pool
water.
Pu
mp
#
2
Fr
om
10
" to
18
"
NOTE: Check valves must be used on the discharge
side of each pump. Minimum 4" pipe between pump
and BaduStream plumbing manifold.
NOTE: Increase pipe size to 6" when jets are
more than 30 feet from pump. Use 6" x 4"
bushings after 4" manifold tees.
10
" to
18
"
4" P
ipe
4"
Pip
e
4" E
lbo
w 4
5
4 " T
ee
4 " P
ipe
4"
Pip
e
4" E
lbo
w 4
5
4" P
ipe
4 " T
ee
4"
Pip
e
4 " P
ipe
4"
Pip
e
4" E
lbo
w 4
5
4" P
ipe
4 " T
ee
4"
Pip
e
4"
Pip
e
®