Speck pumps BADUSTREAM II Скачать руководство пользователя страница 9

7. Installation of the Pump and the Control Box

!

CAUTION

!

WARNING

9

Fig. 9

B

ADU 

S

TREAM

 

II

 triple housing installation

                :  Before installing the Speck Pump, read 
the  entire  pump  owner's  manual  found  in  the  pump 
box.

Consult  local  codes  for  minimum  distance  between 
pump and pool. Locate pump as close to the pool as 
practical.

The air button works up to 50 ft. There is 50 ft. of air 
tubing in 

B

ADU

S

TREAM

 

II

 box.

                  : To reduce the risk of injury, do not permit 
children  to  use  this  product  unless  they  are  closely 
supervised at all times.

The  wiring  of  the  pool  motor  and  control  box  should 
be done by a licensed electrician in accordance with 
local  codes.  Be  certain  that  the  motor  frame  and 
control  box  are  grounded.  Motor  name  plate  has 
voltage,  phase,  amp  draw,  and  other  motor 
information as well as wiring connection instructions.

BONDING:

  As  required  by  National  Electrical  Code 

Article  680-22,  the  pump  motor  must  be  electrically 
bonded to the pool structure (reinforced bars, etc.) by 
a solid copper conductor not smaller than No. 8 AWG 
via  the  external  copper  bonding  lug  on  the  pump 
motor.

GROUNDING:

  Permanently  ground  the  pump  motor 

and control box using a conductor of appropriate size. 
Connect  to  the  No.  10  green  headed  ground  screw 
provided inside the motor terminal box.

NOTE:

  Do  not  connect  to  electric  power  supply  until 

unit is permanently grounded.

Section 6 concerns the electric motor and control box 
only since all other parts, the pump, the jet unit, etc. 
have complete and absolute separation from the pool 
water.

Pu

mp

 # 

2

Fr

om

10

" to

 18

"

NOTE:  Check valves must be used on the discharge
side of each pump.  Minimum 4" pipe between pump
and BaduStream plumbing manifold.

NOTE:  Increase pipe size to 6" when jets are
more than 30 feet from pump.  Use 6" x 4" 
bushings after 4" manifold tees.

10

" to

 18

"

4" P

ipe

4" 

Pip

e

4" E

lbo

w 4

5

4 " T

ee

4 " P

ipe

4" 

Pip

e

4" E

lbo

w 4

5

4" P

ipe

4 " T

ee

4" 

Pip

e

4 " P

ipe

4" 

Pip

e

4" E

lbo

w 4

5

4" P

ipe

4 " T

ee

4" 

Pip

e

4" 

Pip

e

®

Содержание BADUSTREAM II

Страница 1: ...ction Optional Round C Adjustable Water Flow Jet Nozzle D Air Regulator adjusts amount of air bubbles in water flow E Control Box with GFCI with pneumatic button and tubing G Optional Massage Hose wit...

Страница 2: ...4 4 Concrete or Gunite Installation Page 5 5 Liner and or Fiberglass Pool Installation Page 6 5a Removal of Liner Page 7 6 Plumbing Suggestions Page 8 9 7 Installation of the Pump and the Control Box...

Страница 3: ...USTREAM II is complete with jet housing 4 HP or 3 5 HP pump control box and optional massage hose The only additional requirement is the plumbing 4 pipe for 4 HP and 3 pipe for 3 HP units G DO NOT sto...

Страница 4: ...on pump model 98 The air regulator assembly hardware is US standard thread The center of the housing the nozzle should be 10 BELOW water level for maximum efficiency The air regulator should be appro...

Страница 5: ...ousing should finish even with inside gunite wall Make sure a V shaped groove is scraped out around the housing approximately 1 1 2 deep to allow marcite to seal against the housing 4 Recheck location...

Страница 6: ...to mark and drill the holes as shown in Fig 4 For the air regulator one 1 2 hole must be provided preferably along the vertical axis approximately 4 ABOVE the water line For Liner pools only two holes...

Страница 7: ...g from the wall NOTE If the two counter sunk bolts part 27 which hold the jet housing to the wall were installed the jet housing should not move and the two remaining bolts can be removed Remove one o...

Страница 8: ...nstallation 4 Elbow 4 Elbow 45 4 Pipe 4 Elbow 4 Pipe 4 Pipe 4 Pipe 10 to 18 NOTE Increase pipe size to 6 when jets are more than 30 feet from pump Use 6 x 4 bushings after 4 manifold tees 4 Elbow 45 4...

Страница 9: ...trical Code Article 680 22 the pump motor must be electrically bonded to the pool structure reinforced bars etc by a solid copper conductor not smaller than No 8 AWG via the external copper bonding lu...

Страница 10: ...the massage hose with pulsator unless they are closely supervised at all times Close air regulator Reduce the volume of water by turning the adjustable flow nozzle s clockwise Under certain conditions...