manualshive.com logo in svg
background image

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION, OPERATING AND SERVICE MANUAL

READ AND FOLLOW ALL INSTRUCTIONS

This is the

II

All parts are manufactured of corrosion-resistant material and combined in one single
housing (or two single housings for two jet systems) which can be installed in pools of
any size and shape.

Key to illustration:

A. Flush mounted Jet Housing.

B. Square, Anti-Entrapment Cover (8 1/4" x 8 1/4")
undetectable pump suction. (Optional Round)

C. Adjustable Water Flow Jet Nozzle.

D. Air Regulator adjusts amount of air bubbles in
water flow.

E. Control Box with GFCI with pneumatic button
and tubing.

G. Optional Massage Hose with pulsator may be
attached to jet nozzle.

Counterstream Swimming Unit

U.S. Patent No. 3.977.027

OWNER'S MANUAL

The Speck

II

Complies with UL 1563

Swimming Pool Equipment
Listing #E212148

F. Speck 4 HP or 3.5 HP self-priming, plastic
pump, single phase with thermal overload (no
motor starter required). Optional three phase
motor and control available (Normal priming
pump available for installation below water level).

II

®

®

®

D

B

C

A

G

F

E

Содержание BADUSTREAM II

Страница 1: ...ction Optional Round C Adjustable Water Flow Jet Nozzle D Air Regulator adjusts amount of air bubbles in water flow E Control Box with GFCI with pneumatic button and tubing G Optional Massage Hose wit...

Страница 2: ...4 4 Concrete or Gunite Installation Page 5 5 Liner and or Fiberglass Pool Installation Page 6 5a Removal of Liner Page 7 6 Plumbing Suggestions Page 8 9 7 Installation of the Pump and the Control Box...

Страница 3: ...USTREAM II is complete with jet housing 4 HP or 3 5 HP pump control box and optional massage hose The only additional requirement is the plumbing 4 pipe for 4 HP and 3 pipe for 3 HP units G DO NOT sto...

Страница 4: ...on pump model 98 The air regulator assembly hardware is US standard thread The center of the housing the nozzle should be 10 BELOW water level for maximum efficiency The air regulator should be appro...

Страница 5: ...ousing should finish even with inside gunite wall Make sure a V shaped groove is scraped out around the housing approximately 1 1 2 deep to allow marcite to seal against the housing 4 Recheck location...

Страница 6: ...to mark and drill the holes as shown in Fig 4 For the air regulator one 1 2 hole must be provided preferably along the vertical axis approximately 4 ABOVE the water line For Liner pools only two holes...

Страница 7: ...g from the wall NOTE If the two counter sunk bolts part 27 which hold the jet housing to the wall were installed the jet housing should not move and the two remaining bolts can be removed Remove one o...

Страница 8: ...nstallation 4 Elbow 4 Elbow 45 4 Pipe 4 Elbow 4 Pipe 4 Pipe 4 Pipe 10 to 18 NOTE Increase pipe size to 6 when jets are more than 30 feet from pump Use 6 x 4 bushings after 4 manifold tees 4 Elbow 45 4...

Страница 9: ...trical Code Article 680 22 the pump motor must be electrically bonded to the pool structure reinforced bars etc by a solid copper conductor not smaller than No 8 AWG via the external copper bonding lu...

Страница 10: ...the massage hose with pulsator unless they are closely supervised at all times Close air regulator Reduce the volume of water by turning the adjustable flow nozzle s clockwise Under certain conditions...

Страница 11: ...5 1 Hose 8 x 3 16 2 Hose Clamp 14 9 17 1 Holder Air Regulator 18 2 Bolt 1 4 20 x 1 1 2 19 2 Nut 1 4 20 20 2 21 1 Gasket 60 x 11 x 2 22 26 1 Subassembly Complete 22 1 Top Part Air Regulator 23 1 Bottom...

Страница 12: ...hall notify Speck Pumps of such claim by telephone or by mail After the customer has been authorized to return a defective BADUSTREAM II the customer must return the BADUSTREAM II to Speck Pumps Any g...

Отзывы: