background image

6

M017837080000 REV. January 19, 2011

2EZ Speed

TM

 Pool Motor with Programmable Control/Timer

M017837080000 REV. January 19, 2011

7

2EZ Speed

TM

 Pool Motor with Programmable Control/Timer

user Interface Identi cation

This section describes the motor’s user interface. 

run/SToP

 button. This button is used to activate or stop the unit operation. The button 

will be not be lit when power is applied to the user interface while in STOP mode and 

will be illuminated if in the run mode. 

  NOTICE

!

This button does 

noT

 disconnect 

power to the unit.

Press the 

EnTEr

 button to confirm and save your selections. Use the 

 

 arrow keys 

for menu navigation purposes and the 

 

 keys for changing values. For example, while 

changing the time, 

 

 keys will move you from the hours to the minute’s field, while 

the 

 

 keys will change the hour from 10 to 11 etc.

High Speed override

 – Runs the motor on high speed and sets countdown timer for 

60 minutes and will begin counting down. Pressing the button again will end override.

Low Speed override

 – Runs the motor on low speed and sets countdown timer for 

60 minutes and will begin counting down. Pressing the button again will end override.

1

2

3

4

General Installation Instructions

Follow these instructions to prolong the life of your 

swimming pool pump motor/control.

 

a.

  Protection against Heat

    •  Shade the motor/control from the sun.
    •  Provide ample cross ventilation.
    •   Protect the motor/control from lint, etc.,  

that can plug the ventilation openings.

 

b.

  Protection against Dirt

    •   Keep motor/control and surrounding area clean.
    •   Avoid sweeping or stirring dust near the motor/

control while it is running.

    •   Avoid storing or spilling dry chemicals near  

the motor/control.

 

c.

   Protection against Moisture

    •   Shade the motor/control from rain, snow, etc.
    •    Do not wrap motor/control with plastic or other  

air tight materials.

    •    Locate motor/control on a slight elevation so water 

will not run or puddle nearby.

    •   Avoid splashing water on or near the motor/control.
    •    Contact qualified service person to repair leaky  

pipe joints or pump seals promptly.

Basic Motor/Timer operation

WARNING

!

 

A properly  un tionin  motor may 

e too hot to tou h and  ause in ury

 Be careful when 

touching the exterior of an operating motor! This condition 

is normal for most motors when operated at rated load  

and voltage.

Your 2EZ Speed

TM

 motor/timer has been fully tested for 

pool pump use before shipment. It is designed to be a 

drop-in replacement for a standard single or two-speed 

pool pump motor with only minor programming required. 

To operate the motor control/timer, the installer must first 

set the time of day and the day of the week. Please see the 

specific sections of this manual for additional information.

Visually re-inspect the installation. Make sure that guards 

and other protective devices are securely in place.  

All covers and gaskets must be re-installed to minimize  

the entry of dirt and moisture.

www.nidec-motor.com/Pool

MEnu

HIGH SPEED 

o ErrIDE

LoW SPEED 

o ErrIDE

run / SToP

Low    High 

1 :  AM

MTuWThFSaSu

Program

Press Enter to Con rm

Set Clock 

Set on Time 

Set off Time 

override

EnTEr

1

3

4

2

Содержание BADU ECOM2/S90

Страница 1: ...Installation Operating and Service Manual BADU EcoM2 S90 Swimming Pool Pump...

Страница 2: ...cksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Manufactured by Speck Pumps Jacksonville F...

Страница 3: ...fore using 8 TO REDUCE RISK OF ELECTRICAL SHOCK A copper bonding connector 8 AWG is provided for bonding the motor to all metal parts of the swimming pool spa or hot tub structure and to all electrica...

Страница 4: ...both the suction and discharge line in the event that the pump must be removed for servicing 5 Before starting the pump for the first time remove the see through lid Turn lid ring counterclockwise to...

Страница 5: ...pump Option 1 Drain all the water from the pump system equipment and piping Remove drain plugs DO NOT replace plugs Store the plugs in the empty strainer basket for winter Keep the motor covered and...

Страница 6: ...on Repair leak Check suction pipe see through lid in place O ring clean Remove blockage or increase suction pipe size Make sure strainer tank is clean Are all suction valves fully open Disassemble pum...

Страница 7: ...imited Warranty will be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations to Buyer or with respect to the pump and motor in the ev...

Страница 8: ...ILITY PRODUCTS LIABILITY OR OTHERWISE AND EVEN IF ANY REMEDY STATED HEREIN FAILS OF ITS ESSENTIAL PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF SPECIAL INDIRECT INCIDENTAL EXEMPLARY...

Страница 9: ...Save this instruction manual for future reference TWO SPEED POOL MOTOR WITH PROGRAMMABLE CONTROL TIMER These instructions cover the motor and the operation of the user interface timer controller whic...

Страница 10: ...face Identification 7 9 Quick Start Programming 10 Detail Programming 11 13 How to Connect 14 Freeze Sensor 14 Locking the Keypad 15 Operating the 2EZ SpeedTM Pool Motor Control with other Equipment P...

Страница 11: ...mming Supplied with default speed settings Just set the time and day of the week and the timer does the rest To customize your speed settings provide on and off times for Low and High Speeds Energy Ef...

Страница 12: ...eing present at the motor and timer and potential shock hazard To connect power to the motor control timer unit refer to the connection diagram on the motor nameplate and the timer connection label In...

Страница 13: ...CE Become familiar with the equipment and read all instructions thoroughly before installing or working on the equipment NOTICE The 2EZ SpeedTM motor control timer is properly packaged for shipment St...

Страница 14: ...not run or puddle nearby Avoid splashing water on or near the motor control Contact qualified service person to repair leaky pipe joints or pump seals promptly Basic Motor Timer operation WARNING A pr...

Страница 15: ...u navigation purposes and the keys for changing values For example while changing the time keys will move you from the hours to the minute s field while the keys will change the hour from 10 to 11 etc...

Страница 16: ...aSu Program Press Enter to Con rm Set Clock Set on Time Set off Time override EnTEr 1 5 6 7 8 2 3 4 M017837080000 REV January 19 2011 2EZ SpeedTM Pool Motor with Programmable Control Timer user Interf...

Страница 17: ...e select the current day of the week While in RUN mode the current day of the week will be illuminated based on the user setting Press Enter to Con rm is illuminated during the MENU mode This will rem...

Страница 18: ...mming will resume Low Program override LoW SPEED o ErrIDE HIGH SPEED o ErrIDE High Program override 1 M017837080000 REV January 19 2011 2EZ SpeedTM Pool Motor with Programmable Control Timer A Setting...

Страница 19: ...low speed to turn on Pressing ENTER will finalize your selections noTE In each Low or High Setting the user can select the off position when selecting the hour off resides between the hours of 12 and...

Страница 20: ...nd your program settings will take precedence Functions of The Enter Button 1 Press to activate menu selection 2 Press to confirm changes to each menu selection ENTER can be pressed to exit a menu sel...

Страница 21: ...verride or Low Speed override button 1 This button press will only take effect if the timer is enabled RUN STOP button is illuminated 2 After pressing the High Speed Override or Low Speed Override the...

Страница 22: ...this same connection area near the motor terminal board assembly see connection label on motor control Permanent field wiring should be from a 2 pole device a device that disconnects two hot lines See...

Страница 23: ...d stop during the programmed on and off times programmed on your 2EZ SpeedTM pool motor control Be aware of the backup power supply feature on the 2EZ SpeedTM pool motor control as other time clocks m...

Страница 24: ...hen repetitive issues occur Nidec recommends contacting your local pool and spa professional for technical assistance Symptom Possible Causes Corrective Action Motor Control fails to start Blown Fuse...

Страница 25: ...cific legal rights and you may have other rights which vary from state to state Certain repairs or services are the responsibility of the Purchaser and the Purchaser is expected to pay for them This w...

Страница 26: ...Nidec Motor Corporation 8050 W Florissant Avenue St Louis MO 63136 www nidec motor com pool Pool Motor Product Service Hotline 1 800 566 1418...

Страница 27: ......

Страница 28: ......

Отзывы: