Installation
18 EN
10|2018
5 Installation
5.1 Installation
site
5.1.1 Outdoor
installation
In order to increase the pump's service life, provide simple
weather protection.
5.1.2 There
must
be ground drainage
Calculate the size of the ground drain according to the
following criteria:
– Size of the swimming pool.
– Circulation
flow
rate.
5.1.3 Ventilation
and
aeration
Ensure sufficient ventilation and aeration. The ventilation and
aeration must ensure the following conditions:
– Prevention of condensation.
– Minimum
distance
from
fan
cover to the wall: 50 mm.
– Cooling of the pump motor and other system components,
for example switch cabinets and control units.
– Limitation of the ambient temperature to maximum 40 °C.
5.1.4 Structure-borne
and
airborne noise transmission
Observe regulations for structural noise protection, for
example DIN 4109.
Install the pump in a manner which reduces structure-borne
and airborne noise transmission. Vibration-absorbing
materials are suitable bases. Examples:
– Anti-vibration
buffers
– Cork
lining
– Sufficiently
hard
foam
5.1.5 Reserve
space
Measure the reserve space so that the motor unit can be
removed in the direction of the motor fan and the suction
basket and filter unit can be removed upwards. See
dimensional drawing in the pump data sheet.
5.1.6 Fasteners
Fasten pump using screws.
Содержание BADU Star 69/12
Страница 3: ...DE DE Originalbetriebsanleitung Star Komplettfilter D41 04 009 P ...
Страница 7: ...Inhaltsverzeichnis 10 2018 DE 5 10 2 Maßzeichnung 31 10 3 Kennlinie 32 11 Index 33 ...
Страница 36: ......
Страница 37: ...EN EN Translation of original operation manual Star Complete filter D41 04 009 P ...
Страница 41: ...Table of contents 10 2018 EN 5 10 2 Dimensional drawing 31 10 3 Characteristics 32 11 Index 33 ...
Страница 70: ...34 10 2018 ...