Safety
10 EN
10|2018
2.7 Residual
risk
2.7.1 Falling
parts
The lifting hooks on the motor are designed for the weight of the
motor. The lifting hooks can break if the complete pump unit is
attached.
The pump unit, consisting of the motor and the pump, should
be attached on both the motor and pump sides. See point 0
on page 16 .
Only use hoisting and load-bearing equipment which is
suitable and technically sound.
Do
not
stand
under suspended loads.
2.7.2 Rotating
parts
There is a risk of shearing and crushing due to exposed rotating
parts.
Only perform servicing when the pump/unit is not in
operation.
Prior to servicing, ensure the pump/unit cannot be switched
back on.
Immediately after finishing servicing, reattach or reactivate all
protective equipment.
2.7.3 Electrical
energy
There is an increased risk of electric shock when working on the
electrical system due to the humid environment.
Electrical protective earth conductors which were not installed
correctly can also result in electric shocks, for example due to
oxidation or cable breakage.
Observe VDE and utility company regulations.
Build swimming pools and their protection according to
DIN VDE 0100-702.
Before working on the electrical system, take the following
measures:
– Disconnect system from the power supply.
– Attach a warning sign: “Do not switch on! The system is
being worked on.”
– Ensure
that
the
system is free of voltage.
Check the electrical system regularly to ensure it is in proper
working condition.
Содержание BADU Star 69/12
Страница 3: ...DE DE Originalbetriebsanleitung Star Komplettfilter D41 04 009 P ...
Страница 7: ...Inhaltsverzeichnis 10 2018 DE 5 10 2 Maßzeichnung 31 10 3 Kennlinie 32 11 Index 33 ...
Страница 36: ......
Страница 37: ...EN EN Translation of original operation manual Star Complete filter D41 04 009 P ...
Страница 41: ...Table of contents 10 2018 EN 5 10 2 Dimensional drawing 31 10 3 Characteristics 32 11 Index 33 ...
Страница 70: ...34 10 2018 ...