Speakman SE-8000 Скачать руководство пользователя страница 8

EMERGENCY TANK SHOWER TRAINING | PG. 

8

Rough-in

ROUGH-IN

8

119mm

5 "

4

3 "

CL

 TO 

4

CL

1543mm

"

8

1470mm

7

57

60

"

8

1583mm

62 3

5 "

CL

 TO 

8

CL

1413mm

"

4

55

1

1580mm

62

1 58 "

40mm

TYP.

BACK

RIGHT

TOP

T

F

E

L

T

N

O

R

F

43 18 "

1097mm

STROBE
ALARM
(Option)

Activation Push Handle

Walk-On Treadle

LEVEL GAUGE

MECHANICAL WATER

GAUGE (Option)

DIGITAL DISPLAY

Activation (Option)

GRADE

2

 " 83 1

2120mm

7 "

8

7

200mm

153 38 "

3897mm

ACCESS HATCH

B

B

A

A

Modesty (3) Panels
(Option)

1" NPT Water
Supply Inlet

Power Supply Inlet

230V, Single Phase, 50/60Hz

Water Outlet

1" NPT Over-Flow

1-1/2" NPT Sump Catchment
Drain Outlet (Optional)

B

-

B

 

N

O

I

T

C

E

S

A

-

A

 

N

O

I

T

C

E

S

Содержание SE-8000

Страница 1: ...ower optional ts treadle Water collection bund optional ts bund Eyewash with stainless steel bowl optional ts sseyewash Eyewash w Alarm system for both shower eyewash optional ts alarm Alarm System fo...

Страница 2: ...eater that will maintain an approximate water temperature of 86 F at an ambient temperature of 14 F Heat Tracing for Shower and Eyewash Piping PIR Sensor and Area Downlight Thermal cutoff to shutoff e...

Страница 3: ...VC shower valve stainless steel eye wash valve Shower head eye face wash ANSI ISEA Z358 1 2009 Guardian G4710 400 gallons 1514 L Stainless steel frame tank ball valves Shower head eye face wash CSA FS...

Страница 4: ...stable fork truck being used to safely hoist the unit from the shipping crate base Remove top and side panels of shipping crate INSTRUCTIONS FOR MODEL TOOLS AND SUPPLIES Crane Forklift Philips Screwdr...

Страница 5: ...ng all applicable local state and national plumbing codes Remove all lifting braces located at top of unit and inside the shower area along ceiling Save all bracing for future use Remove strap ties ho...

Страница 6: ...The main water supply to the tank shower should be turned off once filling is complete WATER SUPPLY The Tank Shower should only be supplied from a potable water supply See Cleaning Maintenance sectio...

Страница 7: ...ows 1 When the water level drops below a critical level the local alarm will sound and a WATER DROPLET appears on the display screen if the remote alarm option is included then a volt free signal is a...

Страница 8: ...097mm STROBE ALARM Option Activation Push Handle Walk On Treadle LEVEL GAUGE MECHANICAL WATER GAUGE Option DIGITAL DISPLAY Activation Option GRADE 2 83 1 2120mm 7 8 7 200mm 153 3 8 3897mm ACCESS HATCH...

Страница 9: ...ed in accordance with manufacturer s instructions Furthermore Speakman suggests that the unit should be tested at least once a week to check for optimum performance and document data to record results...

Страница 10: ...in tank 2 Check for debris inside the nozzles by unscrewing each nozzle in a count er clockwise direction to unscrew from the eyewash bullhorn Clean out and replace Main overhead shower head spray pat...

Страница 11: ...ree access to the heater location the under ceiling panel should be removed to facilitate access Before any attempt to remove the heating element the power should be isolated and locked off The tank s...

Страница 12: ...rm will sound and a BLUE snowflake appears on the display screen if the remote alarm option is included then a volt free signal is also activated 3 When the water temperature goes above 90 degrees Fah...

Страница 13: ...00 Webpage Product Video EYE FACE WASH FEATURES Yellow Plastic Bowl with 2 yellow plastic spray outlets with flip top dust caps NPT female brass chrome plated full flow stay open ball valve Stainless...

Страница 14: ...dance with all the manufactures recommendations and instructions Q Who to contact for quote A Go to http speakman com sales reps to find a sales rep near you Or call 800 537 2107 for a customer servic...