Speakman SE-8000 Скачать руководство пользователя страница 5

EMERGENCY TANK SHOWER TRAINING | PG. 

5

INSTALLATION

How to install

The Water collection bund is sent 

attached to bottom of the Tank Shower. 

Disconnect, remove and locate and install/

mount Water collection bund into final 

desired position, on suitable concrete 

foundation. Secure using suitable  

mounting hardware at all (4) mounting 

tab locations.

NOTE:

 This surface shall be flat/level and 

suitable to support the weight of the unit 

with a full tank of water (minimum 6000 

lbs. total).

Orient and install unit in final desired  

position either on Water collection bund 

(if supplied) or on suitable concrete 

foundation, and secure using suitable 

mounting hardware at all (4) mounting 

tab locations.

NOTE:

 This surface shall be flat/level and 

suitable to support the weight of the unit 

with a full tank of water (minimum 6000 

lbs. total).

Connect desired drain piping to outlet  

of Water collection bund following all  

applicable local, state, and national  

plumbing codes.

Remove all “lifting” braces located at top 

of unit and inside the shower area, along 

ceiling. Save all bracing for future use.

Remove strap ties holding foot treadle in 

place, if supplied.

Using suitable lifting apparatus (crane, 

etc.) and rigging, properly attach rigging 

to lifting mounts at the top of the unit 

near the tank lid, and carefully stand unit 

upright. Ensure the center of the unit is 

directly under the lifting apparatus at 

all times, until vertical. Watch for unit to 

swing slightly when lifted from floor.

NOTE:

 The tank shower is also supplied 

with forklift truck “lifting” braces, located 

inside the showering area, just below the 

inner ceiling area for easy vertical upright 

lifting using forks from a lift crane or fork 

truck.

Disconnect all temporary shipping  

brackets that are holding the unit in place.

NOTE:

 After removal of support bracket-

ing, if drain sump pan is included proceed 

to step #5, if not proceed To step #7.

5

8

6

9

10

7

Outlet

Typical shipping hold down brackets.

Lift bracing located in shower area, 

near ceiling.

Содержание SE-8000

Страница 1: ...ower optional ts treadle Water collection bund optional ts bund Eyewash with stainless steel bowl optional ts sseyewash Eyewash w Alarm system for both shower eyewash optional ts alarm Alarm System fo...

Страница 2: ...eater that will maintain an approximate water temperature of 86 F at an ambient temperature of 14 F Heat Tracing for Shower and Eyewash Piping PIR Sensor and Area Downlight Thermal cutoff to shutoff e...

Страница 3: ...VC shower valve stainless steel eye wash valve Shower head eye face wash ANSI ISEA Z358 1 2009 Guardian G4710 400 gallons 1514 L Stainless steel frame tank ball valves Shower head eye face wash CSA FS...

Страница 4: ...stable fork truck being used to safely hoist the unit from the shipping crate base Remove top and side panels of shipping crate INSTRUCTIONS FOR MODEL TOOLS AND SUPPLIES Crane Forklift Philips Screwdr...

Страница 5: ...ng all applicable local state and national plumbing codes Remove all lifting braces located at top of unit and inside the shower area along ceiling Save all bracing for future use Remove strap ties ho...

Страница 6: ...The main water supply to the tank shower should be turned off once filling is complete WATER SUPPLY The Tank Shower should only be supplied from a potable water supply See Cleaning Maintenance sectio...

Страница 7: ...ows 1 When the water level drops below a critical level the local alarm will sound and a WATER DROPLET appears on the display screen if the remote alarm option is included then a volt free signal is a...

Страница 8: ...097mm STROBE ALARM Option Activation Push Handle Walk On Treadle LEVEL GAUGE MECHANICAL WATER GAUGE Option DIGITAL DISPLAY Activation Option GRADE 2 83 1 2120mm 7 8 7 200mm 153 3 8 3897mm ACCESS HATCH...

Страница 9: ...ed in accordance with manufacturer s instructions Furthermore Speakman suggests that the unit should be tested at least once a week to check for optimum performance and document data to record results...

Страница 10: ...in tank 2 Check for debris inside the nozzles by unscrewing each nozzle in a count er clockwise direction to unscrew from the eyewash bullhorn Clean out and replace Main overhead shower head spray pat...

Страница 11: ...ree access to the heater location the under ceiling panel should be removed to facilitate access Before any attempt to remove the heating element the power should be isolated and locked off The tank s...

Страница 12: ...rm will sound and a BLUE snowflake appears on the display screen if the remote alarm option is included then a volt free signal is also activated 3 When the water temperature goes above 90 degrees Fah...

Страница 13: ...00 Webpage Product Video EYE FACE WASH FEATURES Yellow Plastic Bowl with 2 yellow plastic spray outlets with flip top dust caps NPT female brass chrome plated full flow stay open ball valve Stainless...

Страница 14: ...dance with all the manufactures recommendations and instructions Q Who to contact for quote A Go to http speakman com sales reps to find a sales rep near you Or call 800 537 2107 for a customer servic...