SV Series
Spa Controls
23
Setup Menu
Setup menu item details
D.DIS Default Display Mode
This setting allows adjustment of the default display mode.
The d.DIS setting choices are:
W.TMP
Water Temperature (Default on SV3/SV4 models)
S.TMP
Set Temperature
(Default on SV2 models)
TIME
Time & Day
T.OUT Adjustable Load Time Out
All accessory loads (ie. jet pumps and/or air blower) automatically turn off after a time
out period has elapsed. Fifteen (15) minutes later the lights will switch off and the pool
will return to automatic mode. This setting allows the length of the time out period to be
adjusted.
The T.OUT setting ranges from: 10 to 60 minutes
Default = 30 minutes
H.PMP Heat Pump Operating Mode
This setting defines the heat pump mode of operation.
The H.PMP setting choices are:
AUTO Heat pump will heat and cool (Default)
HEAT Heat pump will only heat
COOL Heat pump will only cool (SV element heating also disabled)
OFF
Heat pump disabled
H.ELE Heat Pump with SV Element Boost
This setting defines how the in-built SV electric heating element operates with a heat
pump (if fitted). Set to OFF to disable electric heating. Set to ON to allow the SV electric
element to boost heat pump heating if the water temperature is 2
o
C or more below set
temperature point or the heat pump has been operating for more than 1 hour.
The H.ELE setting choices are:
OFF
SV element disabled (heat pump only)
ON
SV e Heat Pump for heating
Default = OFF
EXIT
Exit setup menu
IMPORTANT NOTES
•
If the ambient temperature is below the operational limit of the heat pump (-10
o
C)
the in-built SV electric heating element will automatically be enabled regardless of
the H.ELE setting.