SV Series

 Spa Controls 

22

 

 

Setup Menu

 

Setup menu item details 

 
 
 
 

MODE  Operating Mode 

 
The SV controllers feature four different operating modes that effect demand heating 
and filtration behaviour (refer table below).  
 

Item 

  Mode         Notes 

 

NORM

*

    Normal         Normal operation for demand heating and filtration 

 

ECON 

  Economy    Demand heating can only occur when filtration pump is running 

 
AWAY    Away         Demand heating is DISABLED. Filtration is fixed at 1 hour  

 

 

 

       per day (the keypad will scroll “AWAY MODE” every 60 secs) 

 

WEEK 

 Week 

       Monday to Thursday: Demand heating is DISABLED and filtration  
       fixed at 1 hour per day. Friday to Sunday: Normal Operation 

 

* Default Setting = NORM 

 
 
 

FILT 

Filtration (hours per day) 

 
Automatic filtration is provided to ensure that the pool water is filtered for at least a 
minimum time each day after considering how often the pool has had manual use or 
how long the filtration pump runs for water temperature maintenance. All time spent 
running the pump under normal operation (manual use, water temperature 
maintenance, sanitisation cycles) will be taken into account and where required the 
pump will run for additional periods throughout the day to maintain the minimum level 
of daily filtration as specified by the user. SV controllers support two different types of 
pump for heating and filtration. The default filtration hours and adjustment limits differ 
for each pump type as follows: 

 

 

Small circ pump

 

Jet pump

 

 

(2A or less) 

(2spd or 1spd) 

Minimum filtration hrs p/day 

Maximum filtration hrs p/day 

24 

Default filtration hrs p/day 

 

 

F.CYC  Filtration Cycle Blocks (how often filtration cycles occur) 

 
This setting allows the user to adjust the frequency of the filtration cycle(s). The user can 
set filtration blocks to occur every hour, right down to once a day, or somewhere in 
between. 

 

Select filtration to occur every 1 / 2 / 3 / 4 / 6 / 8 / 12 or 24 hours 
Default setting = 4 hrs (i.e. a filtration block will run every 4 hours) 

 
 
 
SNZE  Sleep Timers 

 
Programmable feature to disable automatic heating and filtration to stop all spa activity 
during certain times of day or night (refer detailed notes on page 24). 

 

Default Setting = Sleep Timer 1 (Sat – Fri; Sleep period 22:00 – 07:00) 
 
 
 

P.SAV  Power Save Setting (off peak filtration and heating) 

 
Lower daily operating costs by programming either filtration only (LOW), or both 
filtration and heating (HIGH) to occur during off-peak power periods when the electricity 
rates are cheaper (refer detailed notes on page 25). 

 

The setting choices are: OFF  /  LOW 

(off-peak filtration) 

 /  HIGH 

(off-peak filtration & heating)

 

Default Setting = OFF 
 
 
 

W.CLN  Automatic Daily Sanitise Cycle Run Time 

 
SV controllers are automatically programmed to activate a 10 minute daily sanitisation 
cycle at a given time, where each pump/blower is operated to purge pipe work whilst 
operating the filtration pump. This setting allows adjustment of the start time of the 
automatic daily sanitise cycle.  

 

Setting ranges from 00:00 to 23:59 
Default = 09:00 (9AM) 

Содержание SV2

Страница 1: ......

Страница 2: ...djusting Set Temperature Point 11 Heater Operating Mode 12 Heating Control Protection 13 Pump Operation 14 Air Blower Operation 15 Light Operation SV2 T models 16 Light Operation SV3 T SV4 T models 17 Sanitise Cycles 18 Special Function Buttons 19 Keylock 20 ADVANCED CONFIGURATION SETTINGS Setup Menu 21 Sleep Timers SNZE 24 Power Save Setting P SAV 25 Error Codes Troubleshooting 26 Heat Pump Error...

Страница 3: ... to this appliance Read and follow all wiring instructions when connecting to power supply Any damaged cable must be replaced immediately To prevent electric shock hazard and or water damage to this appliance all unused receptacles must have a water proof seal in place Parts incorporating electrical components must be located or fixed so that they cannot fall into the bath or spa Parts containing ...

Страница 4: ...MAINTENANCE It is your responsibility to regularly check and maintain the chemical water balance of the spa pool to ensure it remains within reasonable pH acid alkaline limits 7 4 7 6 pH Unbalanced water chemistry greatly accelerates corrosion and may lead to early product or component failure Product or component failures caused as a result of poor water chemistry maintenance will NOT be covered ...

Страница 5: ...rgy efficient heat pump to the spa heating cooling contr0l system The SV heat pump interface revolutionises spa temperature control We can now offer both automatic heating and cooling of the spa water from 10 C 40 C all conveniently controlled via the spa side keypad whilst also providing greatly reduced heat recovery times which can be further reduced with the exclusive SV element boost and fast ...

Страница 6: ...isplay modes DOWN BUTTON Short single presses toggle through the three display modes W TMP Water Temperature S TMP Set Temperature TIME Clock Holding the button will force the controller to begin adjusting the set temperature and will lower the set temperature point Also used for adjusting settings LIGHT BUTTON Press to toggle spa lights on off When light is first turned on the user has the abilit...

Страница 7: ...y modes W TMP Water Temperature S TMP Set Temperature TIME Clock Holding the button will force the controller to begin adjusting the set temperature and will lower the set temperature point Also used for adjusting settings SANITISE BUTTON Press once to activate a 20 minute sanitisation and clean up cycle to refresh water quality after spa use A second press will cancel the cycle if already running...

Страница 8: ...itisation and clean up cycle to refresh water quality after spa use A second press will cancel the cycle if already running BLOWER BUTTON Press to toggle blower on off A single press turns blower on in vari speed mode Use up down buttons to vary speed A double press activates the ramping mode PUMP A B C D BUTTONS Used to toggle the filtration pump and or any additional jet pump s on off if fitted ...

Страница 9: ...ontroller will initiate a water priming sequence on start up During a priming sequence the filtration pump will run for up to 20 seconds at a time in an attempt to purge air from the plumbing The keypad display will scroll PRIMING during this sequence If the spa controller is successful in clearing all of the air from the heater tube the system will begin normal operation However if air is still d...

Страница 10: ...Mode Icon Description W TMP Water Temperature S TMP Set Temperature TIME Clock Time Day The default display mode for all SV controller models is W TMP Water Temperature A short single press of the or button will navigate through the different display modes refer illustrations aside The purpose of the different display modes is to allow easy set temperature point and clock adjustment on all SV2 SV3...

Страница 11: ...mode to TIME Press to enter clock adjustment The settings appear in the following order DATE Year yyyy Month mm Day dd Weekday mon sun TIME Format 24 hr 12 hr Hours xx 00 Minutes 00 xx Press the or button to set year month day hours and minutes to change between 24 hour format and 12 hour format Press the button to save each setting and move to the next setting IMPORTANT NOTES Leap years are taken...

Страница 12: ...ime at differing times of day The advanced software constantly monitors and recalculates after each heating filtration cycle to ensure the correct daily filtration time is achieved and desired set water temperature is maintained Unless adjusted the SV controller will automatically heat to and maintain the default temperature of 38 o C The water temperature set point can be adjusted from 10 o C to ...

Страница 13: ...roll AWAY MODE every 60 secs WEEK Week Monday to Thursday Demand heating is DISABLED and filtration fixed at 1 hour per day Friday to Sunday Normal Operation Press and hold and buttons together until MODE is displayed Press button to enter operating mode MODE adjustment Press or to select desired operating mode Press button to confirm and save setting IMPORTANT NOTES The Week mode is ideal for spa...

Страница 14: ...ter and heat pump if fitted will operate however heater load shedding may occur when accessory pumps are running depending on controller settings At the end of each 10 minute WARM cycle the water temperature is checked If it is above 4 o C freeze protection stops and the controller returns to its prior state If the temperature is not above 4 o C another cycle will run Note Freeze protection overri...

Страница 15: ...intention is to make best possible use of these buttons for all possible pump configurations For every press of a pump button the display will temporarily show the selected pump state ON OFF LOW HIGH AUTO and then revert to the default display mode The most common pump configurations and button assignments are referenced in the table aside IMPORTANT NOTES In configurations where a pump button cont...

Страница 16: ...ode then present b SPD blower speed adjustment menu refer illustration aside Press or buttons to increase or decrease the blower speed note bar graph segments adjust with blower speed Press button to exit menu or wait for 10 second display time out Press button a second time to turn blower off Ramping Mode In this mode the blower speed gradually increases and decreases through the blower speed ran...

Страница 17: ...f When light is turned on keypad will display light mode menu showing current light mode in use refer illustration aside Press or button to navigate through choice of light modes WHTE White Light UCLR User Colour FADE Fade Effect STEP Step Effect Press button to confirm light mode selection Dependant on light mode selected the keypad will display one of three light mode option screens refer aside ...

Страница 18: ...to access light mode menu When light is turned on keypad will display light mode menu showing current light mode in use refer illustration aside Press or button to navigate through choice of light modes WHTE White Light UCLR User Colour FADE Fade Effect STEP Step Effect PRTY Party Effect Press button to confirm light mode selection Press to access light speed colour menu Dependant on light mode se...

Страница 19: ...ise cycle Press button again to cancel cycle if desired IMPORTANT NOTES When the cycle is started automatic mode is enabled and if running any additional jet pumps and the blower are turned off If the controller falls within a designated sleep or power save period during a sanitise cycle the controller will not sleep until the sanitise cycle is finished Automatic Daily Sanitise Cycle The controlle...

Страница 20: ...e Day display modes SV3 SV4 Models Invert Display On SV3 and SV4 model controllers the orientation of the keypad display can be inverted flipped 180 o for easy reading in and out of the spa Press button to invert display orientation IMPORTANT NOTES The operation of the and buttons also reverse to match the current display orientation If the display is left in the inverted orientation the display w...

Страница 21: ...esent There are two types of keylock Full Lock all buttons are disabled Partial Lock allows use of pumps blower light and sanitise buttons however prevents adjustment of set temperature and other programmable settings Full Lock Press and hold until LOCK appears on the display Once locked if any button is pressed the key stroke will be ignored and display will show LOCK refer aside To unlock keypad...

Страница 22: ...o adjust setting Press to confirm setting and exit menu Menu Item Setting Notes MODE Operating Mode Normal Economy Away Week Modes FILT Hours of filtration per day 1 to 24 hours F CYC Filtration cycle blocks Set filtration to run every 1 2 3 4 6 8 12 or 24 hrs SNZE Sleep time menu 1 SNZ Sleep timer 1 1 DAY Days of week 1 BGN Begin Time 1 END End Time 2 SNZ Sleep timer 2 2 DAY Days of week 2 BGN Be...

Страница 23: ...pump type as follows Small circ pump Jet pump 2A or less 2spd or 1spd Minimum filtration hrs p day 1 1 Maximum filtration hrs p day 24 8 Default filtration hrs p day 4 3 F CYC Filtration Cycle Blocks how often filtration cycles occur This setting allows the user to adjust the frequency of the filtration cycle s The user can set filtration blocks to occur every hour right down to once a day or some...

Страница 24: ...p mode of operation The H PMP setting choices are AUTO Heat pump will heat and cool Default HEAT Heat pump will only heat COOL Heat pump will only cool SV element heating also disabled OFF Heat pump disabled H ELE Heat Pump with SV Element Boost This setting defines how the in built SV electric heating element operates with a heat pump if fitted Set to OFF to disable electric heating Set to ON to ...

Страница 25: ...erated by manual use without the need to adjust sleep time settings There are two individual sleep timers that can be set each of which can operate on one or more specified weekdays This enables the user to program different sleep times for different days ie weekdays vs weekends as well as custom settings on a particular day time where the user may want the spa silenced Press and hold and buttons ...

Страница 26: ...s button to enter power save P SAV adjustment The power save setting consists of a choice of mode peak power period start time and peak power period end time refer table below Item Description Notes P SAV Power Save Mode Functions disabled during peak power periods OFF P SAV disabled default LOW Filtration disabled HIGH Filtration Heating disabled BGN Begin Time Peak power period begins Adjustable...

Страница 27: ...ecking the heartbeat LED on the front of the spa pack itself ER 2 HEATER PLUG Problem No heater sensor communication Cause Internal heater sensor communication problem Solutions Turn mains power OFF wait 5 minutes then restart spa Contact spa reseller if problem is not resolved with power reset ER 3 WATER PRIME Problem Water prime failed air detected in heater tube Cause Airlock in pipe work low w...

Страница 28: ...d Systematically unplug lights in pool temp sensor keypads and expansion port loads from spa pack one by one to identify faulty part Contact your spa reseller if problem persists ER 8 CTRL FAULT HVS Problem Heater relay is on when it should be off Cause Power surge periods of low or high voltage water on spa pack terminal block relay problem Solutions Turn mains power OFF and back ON again to see ...

Страница 29: ...eat exchanger thermal cut out open IMPORTANT NOTE If a heat pump encounters an error the heat pump will remain disabled until the mains power to the SV spa controller is turned OFF and back ON again The heat pump warning message will continue to scroll every 60 seconds until the power is reset Maintenance Timers SERVICE REMINDER MESSAGES Certain spa manufacturers will choose to take advantage of t...

Страница 30: ...Details Spa Net Pty Ltd Unit 4 103 Railway Road North Mulgrave NSW 2756 Australia Phone 61 2 4587 7766 Fax 61 2 4587 8766 www spanet com au Technical Support Service service spanet com au Accounts Department accounts spanet com au Sales Department sales spanet com au ...

Отзывы: