background image

Important Safety Notice

Read all Instructions before Installing and operating this appliance

• 

The installation in this manual is intended for qualified installers, service technicians or persons with 

similar qualified background. Installation and electrical wiring must be done by qualified profession

-

als and in accordance with all applicable codes and standards, including fire-rated construction.

•  DO NOT

 attempt to install this appliance yourself. Injury could result from installing the unit due to 

lack of appropriate electrical and technical background.

• 

Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any 

parts for installing, cleaning or servicing.

• 

Activating any switch ON before completing installation may cause ignition or an explosion.

• 

Due to the size and weight of this range hood, two people installation is recommended.

 

To reduce the risk of fire, electric shock, or injury to persons:

• 

For general ventilating use only. 

DO NOT

 use to exhaust hazardous or explosive materials and va

-

pors.

• 

The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this 

unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such 

as those published by the National Fire Protection Association (NFPA), and the American Society of 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

• 

Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre

-

vent power from being switched ON accidentally.

• 

Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make 

sure to vent air outside. DO NOT

 vent exhaust into spaces between walls, crawl spaces, ceiling, attics 

or garages.

• 

Ducted fans MUST always be vented to the outdoors.

• 

Use only metal ductwork and this unit MUST be grounded.

• 

Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent 

back drafting.

• 

When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid

-

den utilities.

• 

All electrical wiring must be properly installed, insulated and grounded.

• 

Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.

• 

Check all joints on duct work to insure proper connection and all joints should be properly taped.

• 

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

vendor.

To reduce the risk of a stove top grease fire:

• 

Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease 

should not be allowed to accumulate on fan, baffle, spaces, filter, grease tunnel and oil container.

• 

Always turn range hood ON when cooking at high heat or when cooking flaming foods. 

• 

Use high settings on cooking range only when necessary.

• 

Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers 

that may ignite. Heat oils slowly on low or medium settings.

Page 1

Содержание SV400 SERIES

Страница 1: ... Users Manual Wall Mount Range Hood SPAGNA VETRO SV400 SERIES IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference www KitchenHoods ca ...

Страница 2: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Страница 3: ...go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being...

Страница 4: ...uirements 5 Mount heights clearance 5 6 Calculating vent system length 6 Venting methods ductless conversion 7 Charcoal filters electrical requirements 8 Preparation 9 Installation 10 12 Range hood operations 13 22 USE AND CARE Troubleshooting 23 Use and care information 24 Specifications 24 MAINTENANCE Cleaning 25 Replacing filter light bulb 25 26 WARRANTY Coverage exceptions 27 Disclaimer contac...

Страница 5: ... 1 Set This Guide and Warranty Card 1 Set 5mm x 16mm Screw with Washer 4 Set 4mm x 16mm Tapping Screw 6 Pcs 4mm x 10mm Tapping Screw 16 Pcs Optional Toggle Bolt with Tapping Screw for Air Diverter 2 Set Optional Screw for Charcoal Filter 3 Pcs Aluminum Filter s Lower standard chimney Upper standard chimney Flexible Duct Tube Optional Flappers Parts supplied Range Hood vary with model Mounting Brac...

Страница 6: ...o the coun tertop stove recommend 24 to 31 3 Distance between the countertop stove to the range hood 4 Height of hood and duct cover For the most efficient quiet operation A distance of 24 to 31 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 15 2 cm or bigger round metal aluminum vent work The size...

Страница 7: ... to hood bottom should be no higher than 31 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height abo...

Страница 8: ...s conversion is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters The air is then purified and re circulated back within the home We recommend to ALWAYS exhaust air outside of the home by employing exi...

Страница 9: ...t be connected with copper wire plug only Always use plug provided If not possible connect three wires ac cording to its color black to hot white to neutral and green to ground to house wires and cap with wire connectors Wire sizes copper wire only and connections must conform with the rating of the appliance as specified on the model serial rating label Wire sizes must conform to the requirements...

Страница 10: ...ket holes vent cutout if used and power supply cable cutout on the ceiling Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent see Venting requirements and Electrical requirements Pages 5 8 5 If venting to the outside install vent system see Venting Methods Page 7 Use caulking to seal exterior wall or roof openings 6 Disconnectmainelectricalsupply prepareandrunel...

Страница 11: ...it see Pic 2 d Install the 6 vent with the dampers into the duct connector of the range hood with 4 screws 4x8mm see below e Install the 6 metal duct onto the vent use aluminum tape to seal it and metal tie to secure it f Put the two lower and upper decorative duct cover on the hood then adjust the inner duct cover to the appointed height see Pic5 drill two Ø8 mm holes in a horizontal line for ins...

Страница 12: ...ack in the room Charcoal filters are not washable they need to be replaced every 4 5 months 2 Please note that the air will flow out from the two grids on the two sides of the chimney cover You will need to leave them open 3 When having a recirculated hood pick a blower as big as possible as the air needs to be pushed trough the char coal filter and the blower needs to be more powerful Hav ing a g...

Страница 13: ...Spagna Vetro SV400Z 30 SpagnaVetro SV400D 30 36 ...

Страница 14: ...SpagnaVetro SV400B2 30 SpagnaVetro SV400V 30 36 ...

Страница 15: ...d mode will cancel Press the Light Switch to power on the lights CAUTION DO NOT touch the lights until switched OFFand cooled Turn Off Press the Power Switch to turn off the power Press the Light Switch to power off the lights SV400 Series Standard Class 3 Speed Mechanical Control NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights SV400 Series ...

Страница 16: ...nction will only turn OFF the fan The light settings will not be affected by the delay function If they are ON they will stay ON 10 Minute Delay While the fans are operating touch the Digital Timer clock on left will start flashing and fan will shut OFF after 10 minutes During this 10 minute delay changing speeds will not affect the countdown Immediate Power off Touch the minus Control On Off butt...

Страница 17: ... is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow 4 The lights work but the blower is not spinning at all is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please contact us im mediately Check for objects inside the blower 5 The hood is not venting out properly Make sure ...

Страница 18: ...nents operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers du...

Страница 19: ...h stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Aluminum Grease Filter Stainless Steel Filterless Grill The aluminum filters fitted by the factory are intended to filter out residue and grease from cooking It need not be replaced on a regular basis but are required to be ...

Страница 20: ...ens cover counter clockwise carefully and gently pry up the lens cover Remove the old halogen light bulb by pulling in the direction of wavy arrow Do not touch the new light bulb with bare hands Reverse the steps to install a new halogen light bulb Turn ON breaker and range hood to test for operation WARNING Hazard of Burns Light bulb become extremely hot when turned on DO NOT touch bulb until swi...

Страница 21: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...

Страница 22: ...will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry a service cha...

Страница 23: ...Spagna Vetro Appliances Inc 7272 Buller Ave Burnaby BC Canada www KitchenHoods ca ...

Отзывы: