background image

 

P

REVENT

 

THE

 

HEATER

 

FROM

 

FREEZING

:

 

In

 

very

 

cold

 

areas

 

(with

 

temperatures

 

below

 

0

 

),

 

please

 

remove

 

the

 

draining

 

stopper

 

after

 

use

 

to

 

release

 

access

 

water.

 

It’s

 

also

 

recommended

 

to

 

disconnect

 

the

 

heater

 

and

 

move

 

it

 

to

 

a

 

storage

 

place

 

without

 

risk

 

for

 

freezing.

    

 

Some

 

parts

 

of

 

the

 

water

 

heater

 

may

 

become

 

loose

 

due

 

during

 

transportation.

 

In

 

case

 

of

 

damages

 

to

 

the

 

external

 

housing

 

after

 

opening

 

the

 

package,

 

get

 

a

 

repairman

 

to

 

check

 

before

 

use.

  

 

R

EPLACE

 

THE

 

B

ATTERIES

.

 

 

 

Replace

 

the

 

batteries

 

if

 

you

 

see

 

the

 

following

 

situations

 

upon

 

ignition

 

or

 

as

 

the

 

water

 

comes

 

out.

 

 

Longer

 

interval

 

of

 

sounds

 

of

 

“Pa,Pa”

 

during

 

ignition

 

(approx.

 

2

 

sounds

 

a

 

second)

  

 

The

 

flame

 

goes

 

out

 

shortly

 

after

 

ignition.

 

 

H

OW

 

TO

 

REPLACE

 

THE

 

BATTERIES

:

 

SEE

 

PARAGRAPH

 

“L

OADING

 

THE

 

B

ATTERY

 

FOR

 

DETAIL

 

 

 

Please

 

use

 

moisture

 

proof

 

batteries

 

with

 

a

 

sealed

 

metal

 

shell.

 

Under

 

normal

 

conditions,

 

the

 

batteries

 

need

 

replacing

 

once

 

a

 

year.

  

 

A

BNORMAL

 

H

ANDLE

 

 

 

In

 

case

 

of

 

abnormal

 

burning

 

(flame

retrace

 

separated

 

flame,

 

yellow

 

flame

 

or

 

dark

 

smoke

 

etc.)

 

unexpected

 

smell,

 

noise

 

or

 

emergency

 

(earthquake

 

or

 

fire),remain

 

calm

 

to

 

close

 

the

 

water

 

heater

 

to

 

stop

 

burning,

 

close

 

the

 

gas

 

valve

 

afterwards

 

and

 

contact

 

the

 

service

 

department

 

or

 

the

 

gas

 

supplier.

  

 

M

AINTENANCE

 

&S

ERVICES

 

 

 

 

The

 

water

 

heater

 

needs

 

cleaning

 

periodically

 

(generally

 

once

 

every

 

half

 

year)

 

to

 

ensure

 

its

 

normal

 

performance.

 

Check

 

the

 

flame

 

frequently,

 

in

 

case

 

of

 

a

 

yellow

 

flame

 

with

 

dark

 

smoke,

 

inform

 

the

 

service

 

department

 

for

 

cleaning.

 

To

 

clean

 

the

 

external

 

housing,

 

please

 

gently

 

mop

 

it

 

with

 

a

 

wet

 

cloth

 

followed

 

with

 

a

 

dry

 

cloth.

 

If

 

the

 

water

 

heater

 

remains

 

unused

 

for

 

a

 

long

 

time,

 

cover

 

the

 

top

 

to

 

prevent

 

dust.

 

Never

 

use

 

chemical

 

detergents

 

for

 

cleaning;

 

otherwise,

 

the

 

external

 

housing

 

would

 

become

 

faded

 

and

 

lose

 

its

 

gloss.

 

All

 

abnormalities

 

must

 

only

 

be

 

handled

 

by

 

qualified

 

personnel.

  

 

Note:

  

The

 

room

 

installed

 

with

 

the

 

water

 

heater

 

must

 

have

 

a

 

fixed

 

open

 

air

induction

 

opening.

 

Closed

 

windows

 

are

 

ineffective.

 

 

 

 

Содержание JSD?12L

Страница 1: ...RMATION Read all instructions before using the heater Protect the heater from rain and wind even from water that can flow over the edge use for instance SpaDealers protective box As gas propane LPG with 30 mbar pressure reducer and 2 kg h of gas flow is used Natural gas methane 20 mbar operating pressure can also be used Place the supplied rubber seal between the brass connector and gas inlet on t...

Страница 2: ...E PARAGRAPH LOADING THE BATTERY FOR DETAIL 9 ABNORMAL HANDLE 9 MAINTENANCE SERVICES 9 TROUBLE TROUBLESHOOTING 10 OW121201 HIT2188 Gas water heater Appliance type B11BS Model JSD 12L Type of gas I3P G31 30 mbar 3000Pa 2E G20 20mbar 2000Pa Applicable water pressure 0 25Bar 10Bar 0 025 10 MPa Hot water supply capacity 12L min t 25 Minimum output 8KW Nominal heat input 24KW Voltage DC 3V Destination F...

Страница 3: ...t from the security valve to release pressure ensuring safety for the appliance and the user 6 Equipped with a protection unit to prevent over heating in the water tank and dry burn 7 In the event of pressure fluctuations in the water supply the water heater will maintain a relatively constant outlet water flow This instruction is for the functions of the external housing only and does not represe...

Страница 4: ...a water pressure is required on the installation site to ensure the normal operation of the water heater 5 We recommend a cold water valve be installed close to the water heater for maintenance convenience See Fig 4 6 Keep a minimum space from the wall or ceiling on the installation site Keep clear of stove combustible and dangerous objects See Fig 3 13 15 14 16 Fig 4 7 If it s possible install th...

Страница 5: ...box 2 Load two 1 5V batteries D size into the battery box make sure of the proper polarity Improper polarity will affect the performance of the water heater 3 Close the cover on the battery box INSTALLATION OF GAS PIPE Hose must be designed for LPG gas and a maximum of 1 2 m long and 10 mm internal diameter Or according to other national standard Attachment of the hose must be secured with a hose ...

Страница 6: ... after a long period between uses repeat ignition is needed to discharge any existing air in the gas pipe Use the knob Gas Water and Power to adjust the water temperature With Gas and Power set to the Max position gives the maximum power The knob Water adjust the water flow so that the Max position gives greater water flow and thus lower temperature out from the heater and vice versa For a tempora...

Страница 7: ...SE OF GAS LEAKAGE NEVER MAKE A FIRE OR TOUCH ANY ELECTRIC SWITCHES NOT MAKE TELEPHONE CALL IN THE ROOM OPEN ALL DOORS AND WINDOWS Regularly check the pipe to make sure of good air tightness If cracked replace the pipe at once Under normal conditions the gas pipe needs to be checked once a year If the gas pipe is cracked stop using it and replace it For users of Propane if the flame of the water he...

Страница 8: ...ensure complete burning When in use with natural gas in case of low gas pressure it is highly possible that a flame retrace will be created This can cause a carbon build up in the burner Should this occur the blue flame becomes yellow and the level of carbon monoxide notably rises In such a case stop using the heater and contact the gas supplier PREVENT BURNS ON EYES Upon ignition never look at th...

Страница 9: ...es need replacing once a year ABNORMAL HANDLE In case of abnormal burning flame retrace separated flame yellow flame or dark smoke etc unexpected smell noise or emergency earthquake or fire remain calm to close the water heater to stop burning close the gas valve afterwards and contact the service department or the gas supplier MAINTENANCE SERVICES The water heater needs cleaning periodically gene...

Страница 10: ... valve until burning note remember to keep an interval of minimum 5 seconds between every open and close get a repairman to repair the pressure adjuster Abnormal inlet gas pressure High Low Cold water valve remains closed Fully open the water inlet valve Block in the filter net Clean the filter net Frozen Get unfrozen before use Low cold water pressure Check the water pressure Incorrect way to adj...

Отзывы: