background image

I

NSTALLATION

 

R

EGULATIONS

 

 

 

1.

 

It

 

is

 

forbidden

 

to

 

install

 

this

 

water

 

heater

 

in

 

a

 

closed

 

room.

 

It

 

must

 

be

 

installed

 

in

 

a

 

well

ventilated

 

area

 

larger

 

than

 

7.5

.

 

Because

 

the

 

water

 

heater

 

requires

 

a

 

larger

 

quantity

 

of

 

oxygen

 

when

 

working,

 

the

 

area

 

should

 

have

 

a

 

minimum

  

air

induction

 

opening

 

of

 

0.06

 

(20x30

 

cm).

  

2.

 

Do

 

not

 

install

 

the

 

water

 

heater

 

in

 

a

 

location

 

with

 

strong

 

wind

 

(unless

 

it

 

is

 

protected

 

from

 

the

 

wind);

 

otherwise,

 

the

 

flame

 

may

 

go

 

out

 

or

 

cause

 

incomplete

 

burning.

  

3.

 

It

 

is

 

forbidden

 

to

 

install

 

the

 

heater

 

outside

 

if

 

it’s

 

not

 

protected

 

from

 

wind

 

and

 

rain,

 

because

 

wind

 

and

 

rain

 

may

 

put

 

out

 

the

 

flame;

 

Moreover,

 

the

 

appliance

 

might

 

get

 

frozen

 

and

 

damaged

 

in

 

a

 

cold

 

winter

 

season.

  

4.

 

A

 

water

 

supply

 

with

 

a

 

minimum

 

0.02Mpa

 

water

 

pressure

 

is

 

required

 

on

 

the

 

installation

 

site

 

to

 

ensure

 

the

 

normal

 

operation

 

of

 

the

 

water

 

heater.

  

5.

 

We

 

recommend

 

a

 

cold

 

water

 

valve

 

be

 

installed

 

close

 

to

 

the

 

water

 

heater

 

for

 

maintenance

 

convenience.

  

See

 

Fig

 

4.

  

6.

 

Keep

 

a

 

minimum

 

space

 

from

 

the

 

wall

 

or

 

ceiling

 

on

 

the

 

installation

 

site.

 

Keep

 

clear

 

of

 

stove,

 

combustible

 

and

 

dangerous

 

objects.

  

See

 

Fig

 

3.

 

 

13

15

14

16

 

(Fig.

 

4)

 

7.

 

If

 

it’s

 

possible,

 

install

 

the

 

water

 

heater

 

at

 

the

 

proper

 

height

 

for

 

easy

  

inspection

 

of

 

burning,

 

about

 

1.5m.

  

8.

 

Make

 

sure

 

a

 

proper

 

gas

 

pipe

 

are

 

installed

 

and

 

make

 

sure

 

that

 

the

 

pipe

 

remains

 

airtight

 

and

 

the

 

inlet

 

gas

 

pressure

 

is

 

30mbar,

 

2h/kg

 

for

 

normal

 

operation

 

of

 

the

 

appliance.

 

If

 

using

 

a

 

piped

 

gas

 

supply,

 

ask

 

the

 

gas

 

supplier

 

or

 

the

 

gas

 

administration

 

authority

 

for

 

pipe

 

connecting.

 

9.

 

See

 

OTHER

 

IMPORTANT

 

CAUTIONS

 

for

 

other

 

regulations.

  

(Fig.

 

3)

 

4

13 15 14

17

13.

 

Gas

 

inlet

 

14.

 

Water

 

inlet

 

(cold)

 

15.

 

Water

 

outlet

 

(warm)

 

16.

 

Water

 

valve

 

17.

 

Air

 

hole

 

 

Содержание JSD?12L

Страница 1: ...RMATION Read all instructions before using the heater Protect the heater from rain and wind even from water that can flow over the edge use for instance SpaDealers protective box As gas propane LPG with 30 mbar pressure reducer and 2 kg h of gas flow is used Natural gas methane 20 mbar operating pressure can also be used Place the supplied rubber seal between the brass connector and gas inlet on t...

Страница 2: ...E PARAGRAPH LOADING THE BATTERY FOR DETAIL 9 ABNORMAL HANDLE 9 MAINTENANCE SERVICES 9 TROUBLE TROUBLESHOOTING 10 OW121201 HIT2188 Gas water heater Appliance type B11BS Model JSD 12L Type of gas I3P G31 30 mbar 3000Pa 2E G20 20mbar 2000Pa Applicable water pressure 0 25Bar 10Bar 0 025 10 MPa Hot water supply capacity 12L min t 25 Minimum output 8KW Nominal heat input 24KW Voltage DC 3V Destination F...

Страница 3: ...t from the security valve to release pressure ensuring safety for the appliance and the user 6 Equipped with a protection unit to prevent over heating in the water tank and dry burn 7 In the event of pressure fluctuations in the water supply the water heater will maintain a relatively constant outlet water flow This instruction is for the functions of the external housing only and does not represe...

Страница 4: ...a water pressure is required on the installation site to ensure the normal operation of the water heater 5 We recommend a cold water valve be installed close to the water heater for maintenance convenience See Fig 4 6 Keep a minimum space from the wall or ceiling on the installation site Keep clear of stove combustible and dangerous objects See Fig 3 13 15 14 16 Fig 4 7 If it s possible install th...

Страница 5: ...box 2 Load two 1 5V batteries D size into the battery box make sure of the proper polarity Improper polarity will affect the performance of the water heater 3 Close the cover on the battery box INSTALLATION OF GAS PIPE Hose must be designed for LPG gas and a maximum of 1 2 m long and 10 mm internal diameter Or according to other national standard Attachment of the hose must be secured with a hose ...

Страница 6: ... after a long period between uses repeat ignition is needed to discharge any existing air in the gas pipe Use the knob Gas Water and Power to adjust the water temperature With Gas and Power set to the Max position gives the maximum power The knob Water adjust the water flow so that the Max position gives greater water flow and thus lower temperature out from the heater and vice versa For a tempora...

Страница 7: ...SE OF GAS LEAKAGE NEVER MAKE A FIRE OR TOUCH ANY ELECTRIC SWITCHES NOT MAKE TELEPHONE CALL IN THE ROOM OPEN ALL DOORS AND WINDOWS Regularly check the pipe to make sure of good air tightness If cracked replace the pipe at once Under normal conditions the gas pipe needs to be checked once a year If the gas pipe is cracked stop using it and replace it For users of Propane if the flame of the water he...

Страница 8: ...ensure complete burning When in use with natural gas in case of low gas pressure it is highly possible that a flame retrace will be created This can cause a carbon build up in the burner Should this occur the blue flame becomes yellow and the level of carbon monoxide notably rises In such a case stop using the heater and contact the gas supplier PREVENT BURNS ON EYES Upon ignition never look at th...

Страница 9: ...es need replacing once a year ABNORMAL HANDLE In case of abnormal burning flame retrace separated flame yellow flame or dark smoke etc unexpected smell noise or emergency earthquake or fire remain calm to close the water heater to stop burning close the gas valve afterwards and contact the service department or the gas supplier MAINTENANCE SERVICES The water heater needs cleaning periodically gene...

Страница 10: ... valve until burning note remember to keep an interval of minimum 5 seconds between every open and close get a repairman to repair the pressure adjuster Abnormal inlet gas pressure High Low Cold water valve remains closed Fully open the water inlet valve Block in the filter net Clean the filter net Frozen Get unfrozen before use Low cold water pressure Check the water pressure Incorrect way to adj...

Отзывы: