I
NSTALLATION
OF
H
OT
AND
C
OLD
W
ATER
P
IPE
Use
hoses
that
can
withstand
pressure
to
connect
incoming
and
outgoing
water
connection.
Note
that
the
outgoing
pipe
also
must
withstand
temperatures
up
to
70
°C
U
SER
I
NSTRUCTIONS
B
EFORE
S
TART
I
GNITION
Please
check
to
make
sure
that
the
gas
type
is
in
accordance
with
the
one
stipulated
on
the
name
plate
(see
page
2).
Before
igniting,
open
the
cold
water
valve.
Open
the
master
gas
switch
and
check
that
there
is
no
leakage
(see
further
instructions
on
page
7).
S
TART
IGNITION
,
W
ATER
C
OMES
O
UT
Start
ignition:
Open
the
cold
water
valve,
(or
start
the
pump)
the
burner
starts
to
ignite
with
a
continuous
“pa”sound,
which
stop
after
burning
starts;
hot
water
comes
out
immediately
Note:
When
using
this
appliance
for
the
first
time,
or
after
a
long
period
between
uses,
repeat
ignition
is
needed
to
discharge
any
existing
air
in
the
gas
pipe.
Use
the
knob
“Gas”,
“Water”
and
“Power”
to
adjust
the
water
temperature.
With
“Gas”
and
“Power”
set
to
the
Max
position
gives
the
maximum
power.
The
knob
"Water"
adjust
the
water
flow
so
that
the
Max
position
gives
greater
water
flow
and
thus
lower
temperature
out
from
the
heater
and
vice
versa.
For
a
temporary
stop
during
use,
close
the
hot
water
valve
or
stop
the
pump.
The
burner
will
stop
burning
automatically.
Open
the
valve
or
start
the
pump
for
hot
water
again.
Note:
Because
the
water
will
get
very
hot
during
a
temporary
stop,
wait
for
a
few
seconds
before
coming
into
contact
with
the
water
S
TOPPING
THE
HEATER
(
WATER
STOPS
COMING
OUT
)
To
stop
the
water
heater
after
use,
close
the
hot
water
valve
or
stop
the
pump,
the
flame
of
the
burner
will
go
out
automatically,
and
the
water
heater
stops
working.
Close
the
cold
water
valve
or
pump.
Close
the
master
gas
valve.