INSTRUCTION, USE AND
MAINTENANCE MANUAL
Page 27 of 45
GB
13.0 ROUTINE MAINTENANCE
BEFORE CARRYING OUT ANY ROU-
TINE MAINTENANCE PROCEDURE,
DISCONNECT THE MACHINE
FROM ITS POWER SUPPLY SOURC-
ES, TAKING SPECIAL CARE OF
THE ELECTRICAL PLUG/SOCKET
CONNECTION.
To guarantee the efficiency and correct functioning
of the machine, it is essential to carry out daily or
weekly cleaning and weekly routine maintenance, as
described below.
Cleaning and routine maintenance must be conducted
by authorized personnel and according to the instruc-
tions given below.
• Disconnect the mains power supply before starting
any cleaning or routine maintenance operations.
• Periodically check the calibration of the lubricator
of the pressure regulator/oiler unit: 1 oil drop every
four complete strokes of self-centering chuck jaws.
• Remove deposits of tyre powder and other waste
materials with a vacuum cleaner.
BEFORE CARRYING OUT ANY
MAINTENANCE OPERATIONS,
MAKE SURE THERE ARE NO
WHEELS CLAMPED ON THE MAN-
DREL AND THAT ALL SUPPLIES
TO THE MACHINE HAVE BEEN
DISCONNECTED.
DO NOT BLOW IT WITH COMPRESSED AIR.
• Do not use solvents to clean the pressure regulator.
• The conditioning unit is equipped with an automatic
vacuum-operated drain therefore it requires no
manual intervention by the operator (see
Fig. 27
).
PRESSURE
REGULATOR
AIR
SUPPLY
AUTOMATIC
DEPRESSURE
RELEASE
OILER
Fig. 27
IN ORDER TO ALLOW A LONGER
LIFE OF THE FILTER AND OF ALL
MOVING PNEUMATIC DEVICES,
YOU HAVE TO MAKE SURE THAT
THE SUPPLIED AIR IS:
• EXEMPT FROM THE LUBRICAT
-
ING OIL OF THE COMPRESSOR;
• EXEMPT FROM HUMIDITY;
• EXEMPT FROM IMPURITY.
• Every
week
and/or when necessary, top up the oil
tank using the filler hole provided closed by a cap
or screw on the lubricator filter.
NOTE: This operation should not be carried out
by unscrewing the cup of the lubricator filter.
• The use of synthetic oil might damage the pressure
regulator filter.
• Replace worn pieces (tool supports, rubber pads,
lever guard, mounting tool) immediately.
• Periodically (preferably once a month) make a
complete check on the controls, ensuring that they
provide the specified actions.
•
Every week
check operation of the safety device.
•
Periodically
(at least each 100 working hous) check
the lubricant level into the reduction unit (
Fig. 28
ref. 1
) removing the plug (
Fig. 28 ref. 2
) through
the spy hole prearranged on the frame.
Fig. 28
Space s.r.l.
7300-M009-0_P
GA2645 - GA2645D - GA2645V